2
-
-
0032647527
-
An example of model evaluation by experimental comparison: Pollutant spread in an apartment
-
Bossaer A, Ducarme D, Wouters P and Vandaele L: (1999) "An example of model evaluation by experimental comparison: pollutant spread in an apartment". Energy and Buildings, 30 pp53-59.
-
(1999)
Energy and Buildings
, vol.30
, pp. 53-59
-
-
Bossaer, A.1
Ducarme, D.2
Wouters, P.3
Vandaele, L.4
-
4
-
-
77956579234
-
-
Energy plus website
-
Energy plus website: http://www.eere.energy.gov/buildings/energyplus/cfm/ weather-data.cfm.
-
-
-
-
6
-
-
77956564600
-
-
GB/T 18883-2002: the State Environment Protection Administration (SEPA) and the Ministry of Health
-
GB/T 18883-2002: (2002) "Standard for Indoor Air Quality", the State Environment Protection Administration (SEPA) and the Ministry of Health.
-
(2002)
Standard for Indoor Air Quality
-
-
-
8
-
-
33751187417
-
Measurement and analysis of temperature difference correction factor for residential stairwell
-
(in Chinese with English abstract)
-
Li Z: (2003) "Measurement and analysis of temperature difference correction factor for residential stairwell". HV&AC, 33, pp38-40 (in Chinese with English abstract).
-
(2003)
HV&AC
, vol.33
, pp. 38-40
-
-
Li, Z.1
-
9
-
-
0032647807
-
COMIS-an international multizone airflow and contaminant transport model
-
Feustel HE: (1999) "COMIS-an international multizone airflow and contaminant transport model". Energy and buildings, 30, pp3-18.
-
(1999)
Energy and Buildings
, vol.30
, pp. 3-18
-
-
Feustel, H.E.1
-
10
-
-
0007993954
-
-
International Energy Agency - Air Infiltration and Ventilation Centre, Technical Note AIVC 29, Coventry, UK
-
Feustel HE, Allard F, Dorer VB, Rodriguez EG, Herrlin MK, Liu M, Phaff H, Utsumi H and Yoshino H: (1990) "Fundamentals of the Multizone Air Flow Model - COMIS", International Energy Agency - Air Infiltration and Ventilation Centre, Technical Note AIVC 29, Coventry, UK.
-
(1990)
Fundamentals of the Multizone Air Flow Model - COMIS
-
-
Feustel, H.E.1
Allard, F.2
Dorer, V.B.3
Rodriguez, E.G.4
Herrlin, M.K.5
Liu, M.6
Phaff, H.7
Utsumi, H.8
Yoshino, H.9
-
11
-
-
0026711322
-
A survey of airflow models for multizone structures
-
Feustel HE and Dieris J: (1992) "A survey of airflow models for multizone structures". Energy and Buildings, 18, pp79-100.
-
(1992)
Energy and Buildings
, vol.18
, pp. 79-100
-
-
Feustel, H.E.1
Dieris, J.2
-
12
-
-
0026743638
-
Wind pressure distribution around buildings: A parametrical model
-
Grosso M: (1992) "Wind pressure distribution around buildings: a parametrical model". Energy and Buildings, 18, pp 101-131.
-
(1992)
Energy and Buildings
, vol.18
, pp. 101-131
-
-
Grosso, M.1
-
13
-
-
33751300108
-
A review of international ventilation, airtightness, thermal insulation and indoor air quality standards
-
Air Infiltration & Ventilation Centre
-
Limb MJ: (2001) "A review of international ventilation, airtightness, thermal insulation and indoor air quality standards". ATVC TN55, Air Infiltration & Ventilation Centre.
-
(2001)
ATVC TN55
-
-
Limb, M.J.1
-
14
-
-
77956608324
-
The winter machinery ventilation project for energy saving residential buildings in severely cold region
-
(in Chinese with English abstract)
-
Liu Y: (1999) "The winter machinery ventilation project for energy saving residential buildings in severely cold region". Architecture Technology,. 30, pp706-707. (in Chinese with English abstract).
-
(1999)
Architecture Technology
, vol.30
, pp. 706-707
-
-
Liu, Y.1
-
15
-
-
77956607555
-
Research on air infiltration and energy consumption calculating software for multi-storeyed buildings
-
(in Chinese with English abstract)
-
Wang YL and Gao FS: (2003) "Research on air infiltration and energy consumption calculating software for multi-storeyed buildings". HV&AC. 32, pp86-89. (in Chinese with English abstract).
-
(2003)
HV&AC
, vol.32
, pp. 86-89
-
-
Wang, Y.L.1
Gao, F.S.2
-
16
-
-
77956565899
-
Effect of building types on infiltration and energy consumption
-
(in Chinese with English abstract)
-
Wang YL and Gao FS: (2002) "Effect of building types on infiltration and energy consumption". HV&AC, 5, pp4-9. (in Chinese with English abstract).
-
(2002)
HV&AC
, vol.5
, pp. 4-9
-
-
Wang, Y.L.1
Gao, F.S.2
-
17
-
-
77956593745
-
Study on domestic fresh air ventilator
-
(in Chinese)
-
Wang D, Wen ZP and Guan D: (2004) "Study on domestic fresh air ventilator". Energy Conservation. (5) pp28-30 (in Chinese).
-
(2004)
Energy Conservation
, vol.5
, pp. 28-30
-
-
Wang, D.1
Wen, Z.P.2
Guan, D.3
-
18
-
-
0037263821
-
Performance analysis on hybrid ventilation system for residential buildings using a test house
-
Yoshino H, Liu J, Lee J and Wada J: (2003) "Performance Analysis on Hybrid Ventilation System for Residential Buildings Using a Test House", Indoor Air, 13, (Suppl. 6), pp28-34.
-
(2003)
Indoor Air
, vol.13
, Issue.SUPPL. 6
, pp. 28-34
-
-
Yoshino, H.1
Liu, J.2
Lee, J.3
Wada, J.4
-
19
-
-
77956601475
-
The application's analysis of some types of heat exchangers in the fresh air ventilator
-
(in Chinese with English abstract)
-
Zhang XJ, Cao NC and Yang CX: (2001) "The application's analysis of some types of heat exchangers in the fresh air ventilator". Refrigeration Trans. (2) pp28-31 (in Chinese with English abstract).
-
(2001)
Refrigeration Trans
, vol.2
, pp. 28-31
-
-
Zhang, X.J.1
Cao, N.C.2
Yang, C.X.3
-
20
-
-
77956573369
-
Analysis of energy consumption proportion of air infiltration to heat conduction in north China
-
(in Chinese with English abstract)
-
Zhang CM and Gao FS: (2002) "Analysis of energy consumption proportion of air infiltration to heat conduction in north China". Energy Conservation Technology, 20, pp6-28. (in Chinese with English abstract).
-
(2002)
Energy Conservation Technology
, vol.20
, pp. 6-28
-
-
Zhang, C.M.1
Gao, F.S.2
|