메뉴 건너뛰기




Volumn 24, Issue 9, 2008, Pages 891-896

A retrospective comparison of LASIK outcomes for myopia and myopic astigmatism with conventional NIDEK versus wavefront-guided VISX and Alcon platforms

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ASTIGMATISM; CONTROLLED STUDY; EXCIMER LASER; FOLLOW UP; HUMAN; INTERMETHOD COMPARISON; KERATOMILEUSIS; LASER SURGERY; MAJOR CLINICAL STUDY; MEASUREMENT; MYOPIA; MYOPIC ASTIGMATISM; OUTCOME ASSESSMENT; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; REFRACTION ERROR; REFRACTION INDEX; RETROSPECTIVE STUDY; SAFETY; SCANNING LASER OPHTHALMOSCOPY; SPECTACLES; STATISTICAL SIGNIFICANCE; TREATMENT OUTCOME; VISUAL ACUITY;

EID: 56249118022     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081597x-20081101-07     Document Type: Article
Times cited : (18)

References (7)
  • 1
    • 0041942622 scopus 로고    scopus 로고
    • Update on customized excimer ablations: Recent developments reported in 2002
    • Waheed S, Krueger RR. Update on customized excimer ablations: recent developments reported in 2002. Curr Opin Ophthalmol. 2003;14:198-202.
    • (2003) Curr Opin Ophthalmol , vol.14 , pp. 198-202
    • Waheed, S.1    Krueger, R.R.2
  • 2
    • 31944433579 scopus 로고    scopus 로고
    • Wavefront-guided ablation: Evidence for efficacy compared to traditional ablation
    • Netto MV, Dupps W Jr, Wilson SE. Wavefront-guided ablation: evidence for efficacy compared to traditional ablation. Am J Ophthalmol. 2006;141:360-368.
    • (2006) Am J Ophthalmol , vol.141 , pp. 360-368
    • Netto, M.V.1    Dupps Jr, W.2    Wilson, S.E.3
  • 3
    • 4644306596 scopus 로고    scopus 로고
    • Bilateral comparison of wavefront-guided versus conventional laser in situ keratomileusis with Bausch and Lomb Zyoptix
    • Kim TI, Yang SJ, Tchah H. Bilateral comparison of wavefront-guided versus conventional laser in situ keratomileusis with Bausch and Lomb Zyoptix. J Refract Surg. 2004;20:432-438.
    • (2004) J Refract Surg , vol.20 , pp. 432-438
    • Kim, T.I.1    Yang, S.J.2    Tchah, H.3
  • 4
    • 0036853899 scopus 로고    scopus 로고
    • Wavefront-guided versus standard laser in situ keratomileusis to correct low to moderate myopia
    • Nuijts RM, Nabar VA, Hament WJ, Eggink FA. Wavefront-guided versus standard laser in situ keratomileusis to correct low to moderate myopia. J Cataract Refract Surg. 2002;28:1907-1913.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1907-1913
    • Nuijts, R.M.1    Nabar, V.A.2    Hament, W.J.3    Eggink, F.A.4
  • 5
    • 33745220986 scopus 로고    scopus 로고
    • Comparison of LASIK using the NIDEK EC-5000 optimized aspheric transition zone (OATz) and conventional ablation profile
    • Hori-Komai Y, Toda I, Asano-Kato N, Ito M, Yamamoto T, Tsubota K. Comparison of LASIK using the NIDEK EC-5000 optimized aspheric transition zone (OATz) and conventional ablation profile. J Refract Surg. 2006;22:546-555.
    • (2006) J Refract Surg , vol.22 , pp. 546-555
    • Hori-Komai, Y.1    Toda, I.2    Asano-Kato, N.3    Ito, M.4    Yamamoto, T.5    Tsubota, K.6
  • 6
    • 33748629104 scopus 로고    scopus 로고
    • Bilateral comparison of conventional versus topographic-guided customized ablation for myopic LASIK with the NIDEK EC-5000
    • Du CX, Yang YB, Shen Y, Wang Y, Dougherty PJ. Bilateral comparison of conventional versus topographic-guided customized ablation for myopic LASIK with the NIDEK EC-5000. J Refract Surg. 2006;22:642-646.
    • (2006) J Refract Surg , vol.22 , pp. 642-646
    • Du, C.X.1    Yang, Y.B.2    Shen, Y.3    Wang, Y.4    Dougherty, P.J.5
  • 7
    • 33646338488 scopus 로고    scopus 로고
    • Visual experience and patient satisfaction with wavefront-guided laser in situ keratomileusis
    • Tuan KM. Visual experience and patient satisfaction with wavefront-guided laser in situ keratomileusis. J Cataract Refract Surg. 2006;32:577-583.
    • (2006) J Cataract Refract Surg , vol.32 , pp. 577-583
    • Tuan, K.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.