메뉴 건너뛰기




Volumn , Issue , 2006, Pages 173-180

In-situ measurement of the moisture content of building materials using ultra-wideband radio waves

Author keywords

[No Author keywords available]

Indexed keywords

BUILDING MATERIALS; CONSTRUCTION EQUIPMENT; ENGINEERING RESEARCH; GYPSUM; MOISTURE; MOISTURE DETERMINATION; RADIO; RADIO RECEIVERS; WIRELESS TELECOMMUNICATION SYSTEMS; WOOD PRODUCTS;

EID: 56249101336     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (1)

References (12)
  • 1
    • 56249101972 scopus 로고    scopus 로고
    • Derome, D, Teasdale-St.-Hilaire, & Fazio, P. 2001. Methods for Assessment of Moisture Content of Envelope Assemblies. Thermal Performance of the Exterior Envelopes of Buildings VIII. Conference Proceedings, Clearwater Beach, FL, December 2-7, 2001.
    • Derome, D, Teasdale-St.-Hilaire, & Fazio, P. 2001. Methods for Assessment of Moisture Content of Envelope Assemblies. Thermal Performance of the Exterior Envelopes of Buildings VIII. Conference Proceedings, Clearwater Beach, FL, December 2-7, 2001.
  • 2
    • 20344398993 scopus 로고    scopus 로고
    • OET Establishes Waiver Process to Permit Existing Ultra Wideband Devices to Continue Operation
    • Federal Communications Commission, July 12
    • Federal Communications Commission 2002. OET Establishes Waiver Process to Permit Existing Ultra Wideband Devices to Continue Operation. FCC News, July 12, 2002.
    • (2002) FCC News
  • 3
    • 0017437920 scopus 로고
    • Humidity Fixed Points of Binary Saturated Aqueous Solutions
    • Greenspan, L. 1977. Humidity Fixed Points of Binary Saturated Aqueous Solutions. J. Research of the National Bureau of Standards. Vol. 81A, pp. 89-96.
    • (1977) J. Research of the National Bureau of Standards , vol.81 A , pp. 89-96
    • Greenspan, L.1
  • 4
    • 0037479981 scopus 로고    scopus 로고
    • Moisture Sensor Technology - A Summary of Techniques for Measuring Moisture Levels in Building Envelopes
    • Healy, W.M. 2003. Moisture Sensor Technology - A Summary of Techniques for Measuring Moisture Levels in Building Envelopes. ASHRAE Transactions, Vol. 110, pp. 232-242.
    • (2003) ASHRAE Transactions , vol.110 , pp. 232-242
    • Healy, W.M.1
  • 5
    • 20344379948 scopus 로고    scopus 로고
    • Healy, W.M. & van Doorn, E. 2004a. A Preliminary Investigation on the Use of Ultra-Wideband Radar for Moisture Detection in Building Envelopes. ASHRAE Transactions 111.
    • Healy, W.M. & van Doorn, E. 2004a. A Preliminary Investigation on the Use of Ultra-Wideband Radar for Moisture Detection in Building Envelopes. ASHRAE Transactions Vol. 111.
  • 6
    • 85010316789 scopus 로고    scopus 로고
    • Detection of Moisture Accumulation in Wall Assemblies Using Ultra-Wideband Radio Signals. Thermal Performance of the Exterior Envelopes of Buildings IX
    • Clearwater Beach, FL, December 5-10
    • Healy, W.M. & van Doorn, E. 2004b. Detection of Moisture Accumulation in Wall Assemblies Using Ultra-Wideband Radio Signals. Thermal Performance of the Exterior Envelopes of Buildings IX. Conference Proceedings, Clearwater Beach, FL, December 5-10, 2004.
    • (2004) Conference Proceedings
    • Healy, W.M.1    van Doorn, E.2
  • 8
    • 85040208789 scopus 로고
    • Laboratory Evaluation of Nondestructive Methods to Measure Moisture in Built-Up Roofing Systems
    • Gaithersburg, MD
    • Knab, L., Mathey, R. & Jenkinsm D. 1981. Laboratory Evaluation of Nondestructive Methods to Measure Moisture in Built-Up Roofing Systems. NBS Building Science Series 131, Gaithersburg, MD.
    • (1981) NBS Building Science Series , vol.131
    • Knab, L.1    Mathey, R.2    Jenkinsm, D.3
  • 11
    • 0038016161 scopus 로고
    • Instrumentation for Measuring Moisture in Building Envelopes
    • Ten Wolde, A. & Courville, G.E. 1985. Instrumentation for Measuring Moisture in Building Envelopes. ASHRAE Transactions. Vol. 91, pp. 1101-1115.
    • (1985) ASHRAE Transactions , vol.91 , pp. 1101-1115
    • Ten Wolde, A.1    Courville, G.E.2
  • 12
    • 85042247667 scopus 로고
    • Roof Moisture Survey - Ten State of New Hampshire Buildings
    • 77-31, Hanover, NH
    • Tobiasson, W.N., Korhonen, C.J. & T. Dudley 1977. Roof Moisture Survey - Ten State of New Hampshire Buildings. CRREL Report 77-31, Hanover, NH.
    • (1977) CRREL Report
    • Tobiasson, W.N.1    Korhonen, C.J.2    Dudley, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.