메뉴 건너뛰기




Volumn 44, Issue 6, 2008, Pages 475-478

Bone characterization using piezotransducers as biomedical sensors

Author keywords

Biomechanics; Bone; Frequency response function; Injury; Piezoelectric ceramic (PZT)

Indexed keywords

ACTUATORS; AIRCRAFT; BIOMECHANICS; BIOSENSORS; BONE; CERAMIC MATERIALS; MECHANICAL PROPERTIES; MECHANICS; PIEZOELECTRIC ACTUATORS; PIEZOELECTRIC CERAMICS; PIEZOELECTRIC MATERIALS; PIEZOELECTRIC TRANSDUCERS; PIEZOELECTRICITY; PROBABILITY DENSITY FUNCTION; SEMICONDUCTING LEAD COMPOUNDS; SENSORS; STRUCTURAL DYNAMICS;

EID: 56049117873     PISSN: 00392103     EISSN: 14751305     Source Type: Journal    
DOI: 10.1111/j.1475-1305.2007.00397.x     Document Type: Article
Times cited : (30)

References (12)
  • 2
    • 0001406145 scopus 로고
    • On the piezoelectric effect of bone
    • Fukada, E. and Yasuda, I. (1957) On the piezoelectric effect of bone. J. Phys. Soc. Japan 12, 1158-1162.
    • (1957) J. Phys. Soc. Japan , vol.12 , pp. 1158-1162
    • Fukada, E.1    Yasuda, I.2
  • 3
    • 34250501260 scopus 로고
    • Biologic significance of piezoelectricity
    • Bassett, C. A. L. (1968) Biologic significance of piezoelectricity. Calcified Tissue Res., 1, 252.
    • (1968) Calcified Tissue Res. , vol.1 , pp. 252
    • Bassett, C.A.L.1
  • 6
    • 23444438472 scopus 로고    scopus 로고
    • Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete
    • Soh, C. K. and Bhalla, S. (2005) Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete. Smart Mater. Struct. 14, 671-684.
    • (2005) Smart Mater. Struct. , vol.14 , pp. 671-684
    • Soh, C.K.1    Bhalla, S.2
  • 8
    • 33646418979 scopus 로고    scopus 로고
    • Evaluation of modal damping factor as a diagnostic tool for osteoporosis and its relation with serum osteocalcin and collagen I N-telopeptide for monitoring the efficacy of alendronate in ovariectomized rats
    • Christopoulou, G. E., Stavropoulou, A. Anastassopoulos, G, Panteiou, S. D., Papadaki, E., Karamanos, N. K. and Panagiotopoulos, E. (2006) Evaluation of modal damping factor as a diagnostic tool for osteoporosis and its relation with serum osteocalcin and collagen I N-telopeptide for monitoring the efficacy of alendronate in ovariectomized rats. J. Pharmaceutical Biomed. Anal. 41, 891-897.
    • (2006) J. Pharmaceutical Biomed. Anal. , vol.41 , pp. 891-897
    • Christopoulou, G.E.1    Stavropoulou, A.2    Anastassopoulos, G.3    Panteiou, S.D.4    Papadaki, E.5    Karamanos, N.K.6    Panagiotopoulos, E.7
  • 9
    • 34247257033 scopus 로고    scopus 로고
    • PI Ceramic (available at:)
    • PI Ceramic (2007) Product Specifications (available at: http:// www.piceramic.de).
    • (2007) Product Specifications
  • 11
    • 0036787412 scopus 로고    scopus 로고
    • Evolution of the biomechanical material properties of the femur
    • Erickson, G. M. and Catanese, J. and Keaveny, T. M. (2002) Evolution of the biomechanical material properties of the femur. Anat. Rec. 268, 115-124.
    • (2002) Anat. Rec. , vol.268 , pp. 115-124
    • Erickson, G.M.1    Catanese, J.2    Keaveny, T.M.3
  • 12
    • 0035360872 scopus 로고    scopus 로고
    • Modal damping measurement for damage detection
    • Kawiecki, G. (2001) Modal damping measurement for damage detection. Smart Mater. Struct. 10, 466-471.
    • (2001) Smart Mater. Struct. , vol.10 , pp. 466-471
    • Kawiecki, G.1