메뉴 건너뛰기




Volumn 31, Issue 12, 2008, Pages 1641-1645

Application of a clinical magnet over implantable cardioverter defibrillators: Is it safe and useful?

Author keywords

Defibrillation; ICD; Surgery; VT

Indexed keywords

AGED; ARTICLE; AUTOMATIC CARDIOVERSION; CASE REPORT; CORONARY ARTERY BYPASS SURGERY; DEFIBRILLATOR; EMERGENCY HEALTH SERVICE; HEART STIMULATION; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTATION; INTENSIVE CARE UNIT; MEDICAL EXPERT; MEDICAL PERSONNEL; PHYSICIAN; RESUSCITATION; SHOCK; SURGICAL TECHNIQUE;

EID: 56049106342     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2008.01239.x     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0037066020 scopus 로고    scopus 로고
    • American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1996 Guidelines on Perioperative Cardiovascular Evaluation for Noncardiac Surgery)
    • Eagle KA, Berger PB, Calkins H, Chaitman BR, Ewy GA, Fleischmann KE, Fleisher LA, et al. American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1996 Guidelines on Perioperative Cardiovascular Evaluation for Noncardiac Surgery). Circulation 2002 105 : 1257 1267.
    • (2002) Circulation , vol.105 , pp. 1257-1267
    • Eagle, K.A.1    Berger, P.B.2    Calkins, H.3    Chaitman, B.R.4    Ewy, G.A.5    Fleischmann, K.E.6    Fleisher, L.A.7
  • 2
    • 1842789015 scopus 로고    scopus 로고
    • Assessment and management of patients with pacemakers and implantable cardioverter defibrillators
    • Stone KR, McPherson CA. Assessment and management of patients with pacemakers and implantable cardioverter defibrillators. Crit Care Med 2004 32 : S1551 S1565.
    • (2004) Crit Care Med , vol.32
    • Stone, K.R.1    McPherson, C.A.2
  • 3
    • 33747126408 scopus 로고    scopus 로고
    • Pacemakers and implantable cardioverter defibrillators
    • Allen M. Pacemakers and implantable cardioverter defibrillators. Anaesthesia 2006 61 : 883 890.
    • (2006) Anaesthesia , vol.61 , pp. 883-890
    • Allen, M.1
  • 4
    • 18044383757 scopus 로고    scopus 로고
    • Government viewpoint: U.S. Food & Drug Administration: Pacemakers, ICDs and MRI
    • Faris OP, Shein MJ. Government viewpoint: U.S. Food & Drug Administration: Pacemakers, ICDs and MRI. Pacing Clin Electrophysiol 2005 28 : 268 269.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 268-269
    • Faris, O.P.1    Shein, M.J.2
  • 5
    • 18044373054 scopus 로고    scopus 로고
    • Industry viewpoint: St. Jude Medical: Pacemakers, ICDs and MRI
    • Levine PA. Industry viewpoint: St. Jude Medical: Pacemakers, ICDs and MRI. Pacing Clin Electrophysiol 2005 28 : 266 267.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 266-267
    • Levine, P.A.1
  • 6
    • 23644434580 scopus 로고    scopus 로고
    • Industry viewpoint: Medtronic: Pacemakers, ICDs, and MRI
    • Stanton MS. Industry viewpoint: Medtronic: Pacemakers, ICDs, and MRI. Pacing Clin Electrophysiol 2005 28 : 265.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 265
    • Stanton, M.S.1
  • 7
    • 23644454827 scopus 로고    scopus 로고
    • Industry viewpoint: Guidant: Pacemakers, ICDs, and MRI
    • Smith JM. Industry viewpoint: Guidant: Pacemakers, ICDs, and MRI. Pacing Clin Electrophysiol 2005 28 : 264.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 264
    • Smith, J.M.1
  • 8
    • 18044380733 scopus 로고    scopus 로고
    • Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs)
    • Gimbel JR, Kanal E, Schwatz KM, Wilkoff BL. Outcome of magnetic resonance imaging (MRI) in selected patients with implantable cardioverter defibrillators (ICDs). Pacing Clin Electrophysiol 2005 28 : 270 273.
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 270-273
    • Gimbel, J.R.1    Kanal, E.2    Schwatz, K.M.3    Wilkoff, B.L.4
  • 9
    • 33748740922 scopus 로고    scopus 로고
    • Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 Tesla
    • Nazarian S, Roguin A, Zviman MM, Lardo AC, Dickfeld TL, Calkins H, et al. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable- cardioverter defibrillators at 1.5 Tesla. Circulation 2006 114 : 1277 1284.
    • (2006) Circulation , vol.114 , pp. 1277-1284
    • Nazarian, S.1    Roguin, A.2    Zviman, M.M.3    Lardo, A.C.4    Dickfeld, T.L.5    Calkins, H.6
  • 10
    • 3543116170 scopus 로고    scopus 로고
    • Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonante imaging safe: In Vitro and in vivo assessment of safety and function at 1.5 T
    • Roguin A, Zviman MM, Meininger GR, Rodriguez ER, Dickfeld TM, Bluemke DA, Lardo A, et al. Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonante imaging safe: In Vitro and in vivo assessment of safety and function at 1.5 T. Circulation 2004 110 : 475 482.
    • (2004) Circulation , vol.110 , pp. 475-482
    • Roguin, A.1    Zviman, M.M.2    Meininger, G.R.3    Rodriguez, E.R.4    Dickfeld, T.M.5    Bluemke, D.A.6    Lardo, A.7
  • 12
    • 3242768382 scopus 로고    scopus 로고
    • Complete loss of ICD programmability after magnetic resonance imaging
    • Fiek M, Remp T, Reithmann C, Steibeck G. Complete loss of ICD programmability after magnetic resonance imaging. Pacing Clin Electrophysiol 2004 27 : 1002 1004.
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 1002-1004
    • Fiek, M.1    Remp, T.2    Reithmann, C.3    Steibeck, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.