Volumn 29, Issue 4, 2009, Pages 732-739

Experimental and numerical study on the flow fields in upper furnace for large scale tangentially fired boilers

Author keywords

Flow field; Residual swirl; Tangentially fired boiler; Upper furnace; Velocity deviation

Indexed keywords

BOILERS; EXPERIMENTS; FLOW FIELDS; FLUE GASES; FLUES; FURNACES; GAS DYNAMICS; GASES; KETONES; NUMERICAL ANALYSIS; VELOCITY;

EID: 56049098444     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2008.03.047     Document Type: Article
Times cited : (77)

References (16)
  • 1
    • 0008090748 scopus 로고    scopus 로고
    • Study and remedies of flue gas and steam temperature deviation in the horizontal flue gas pass of corner tangentially fired boilers
    • (in Chinese)
    • Guo S.H., Xu T.M., and Hui S.E. Study and remedies of flue gas and steam temperature deviation in the horizontal flue gas pass of corner tangentially fired boilers. Power Engineering 16 (1996) 9-13 (in Chinese)
    • (1996) Power Engineering , vol.16 , pp. 9-13
    • Guo, S.H.1    Xu, T.M.2    Hui, S.E.3
  • 2
    • 0034174128 scopus 로고    scopus 로고
    • Thermal load deviation model for superheater and reheater of a utility boiler
    • Xu L., Khan J.A., and Chen Z. Thermal load deviation model for superheater and reheater of a utility boiler. Applied Thermal Engineering 20 (2000) 545-558
    • (2000) Applied Thermal Engineering , vol.20 , pp. 545-558
    • Xu, L.1    Khan, J.A.2    Chen, Z.3
  • 3
    • 56049096952 scopus 로고    scopus 로고
    • T.M. Xu, S.E. Hui, H.S. Guo, D.E. Che, The developing tendency and countermeasure of the combustion in furnace of large pulverized-coal boilers, in: Proceeding of ICOPE, Shanghai, China, 1995, pp. 305-308.
    • T.M. Xu, S.E. Hui, H.S. Guo, D.E. Che, The developing tendency and countermeasure of the combustion in furnace of large pulverized-coal boilers, in: Proceeding of ICOPE, Shanghai, China, 1995, pp. 305-308.
  • 4
    • 56049117183 scopus 로고
    • Mathematical modeling of fluid flow and mixing in tangentially fired boiler
    • The Combustion Institute, Pittsburgh, PA
    • Bensch W., and Kremer H. Mathematical modeling of fluid flow and mixing in tangentially fired boiler. Proceeding of the 20th Symposium (International) on Combustion (1984), The Combustion Institute, Pittsburgh, PA 549-557
    • (1984) Proceeding of the 20th Symposium (International) on Combustion , pp. 549-557
    • Bensch, W.1    Kremer, H.2
  • 6
    • 56049109060 scopus 로고    scopus 로고
    • K.F. Cen, J.R. Fan, Computer-aided-numerical testing for the flow pattern of a large tangentially-fired furnace in power station, in: Proceedings of the International Power Generation Conference, San Diego, CA, 1991, pp. 1-6.
    • K.F. Cen, J.R. Fan, Computer-aided-numerical testing for the flow pattern of a large tangentially-fired furnace in power station, in: Proceedings of the International Power Generation Conference, San Diego, CA, 1991, pp. 1-6.
  • 7
    • 56049087310 scopus 로고    scopus 로고
    • J.W. Yuan, M.H. Xu, C.Y. Han, Numerical study on gas temperature deviation in a tangentially coal fired boiler of 600 MW unit, in: Proceedings of the Third International Symposium on Coal Combustion, Beijing, 1995, pp. 241-248.
    • J.W. Yuan, M.H. Xu, C.Y. Han, Numerical study on gas temperature deviation in a tangentially coal fired boiler of 600 MW unit, in: Proceedings of the Third International Symposium on Coal Combustion, Beijing, 1995, pp. 241-248.
  • 8
    • 0032025136 scopus 로고    scopus 로고
    • Simulation of the gas temperature deviation in large-scale tangential coal fired utility boilers
    • Xu M., Yuan J., Ding S., et al. Simulation of the gas temperature deviation in large-scale tangential coal fired utility boilers. Computer Methods in Applied Mechanics and Engineering 155 (1998) 369-380
    • (1998) Computer Methods in Applied Mechanics and Engineering , vol.155 , pp. 369-380
    • Xu, M.1    Yuan, J.2    Ding, S.3
  • 9
    • 56049109537 scopus 로고    scopus 로고
    • T.M. Xu, S.E. Hui, Q.L. Zhou, et al., The effect of opposing tangential circle of air flow on flow characteristics in large boiler furnace, in: Proceedings of the Fourth International Symposium on Coal Combustion, Beijing, 1999.
    • T.M. Xu, S.E. Hui, Q.L. Zhou, et al., The effect of opposing tangential circle of air flow on flow characteristics in large boiler furnace, in: Proceedings of the Fourth International Symposium on Coal Combustion, Beijing, 1999.
  • 10
    • 0037409077 scopus 로고    scopus 로고
    • Further study of the gas temperature deviation in large-scale tangentially coal-fired boilers
    • Yin C., Rosendahl L., and Condra T.J. Further study of the gas temperature deviation in large-scale tangentially coal-fired boilers. Fuel 82 (2003) 1127-1137
    • (2003) Fuel , vol.82 , pp. 1127-1137
    • Yin, C.1    Rosendahl, L.2    Condra, T.J.3
  • 11
    • 56049118676 scopus 로고    scopus 로고
    • Yuegui Zhou, Experimental and numerical investigation on flue gas deviation for large capacity tangentially fired boilers, Dissertation, Xi'an Jiaotong University, 1999.
    • Yuegui Zhou, Experimental and numerical investigation on flue gas deviation for large capacity tangentially fired boilers, Dissertation, Xi'an Jiaotong University, 1999.
  • 12
    • 0034883857 scopus 로고    scopus 로고
    • Experimental and numerical study on the flue gas velocity deviation in a tangentially fired boiler furnace
    • (in Chinese)
    • Zhou Y., Zhang M., Xu T., and Hui S. Experimental and numerical study on the flue gas velocity deviation in a tangentially fired boiler furnace. Proceedings of Chinese Society for Electrical Engineering 21 (2001) 68-72 (in Chinese)
    • (2001) Proceedings of Chinese Society for Electrical Engineering , vol.21 , pp. 68-72
    • Zhou, Y.1    Zhang, M.2    Xu, T.3    Hui, S.4
  • 15
    • 0003534171 scopus 로고    scopus 로고
    • Xi'an Jiao Tong University Press, Xi'an
    • Tao W.Q. Numerical Heat Transfer (2001), Xi'an Jiao Tong University Press, Xi'an
    • (2001) Numerical Heat Transfer
    • Tao, W.Q.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.