메뉴 건너뛰기




Volumn 34, Issue 11, 2008, Pages 1477-1485

Correlation between the static and dynamic stiffness indices of medical elastic compression stockings

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; COMPRESSION GARMENT; CORRELATION COEFFICIENT; PRIORITY JOURNAL; RIGIDITY; TENSION; BANDAGE; HUMAN; MEASUREMENT; NOTE; WALKING;

EID: 55949130229     PISSN: 10760512     EISSN: 15244725     Source Type: Journal    
DOI: 10.1111/j.1524-4725.2008.34312.x     Document Type: Article
Times cited : (21)

References (12)
  • 1
    • 0037323468 scopus 로고    scopus 로고
    • Effect of elastic compression stockings on venous hemodynamics during walking
    • Ibegbuna V, Delis K, Nicolaides AN, Aina O. Effect of elastic compression stockings on venous hemodynamics during walking. J Vasc Surg 2003 37 : 420 5.
    • (2003) J Vasc Surg , vol.37 , pp. 420-425
    • Ibegbuna, V.1    Delis, K.2    Nicolaides, A.N.3    Aina, O.4
  • 2
    • 0034461490 scopus 로고    scopus 로고
    • The haemodynamic efficacy of six different compression stockings from compression class 2 in patients suffering from chronic venous insufficiency
    • Häfner HM, Jünger M. The haemodynamic efficacy of six different compression stockings from compression class 2 in patients suffering from chronic venous insufficiency. Phlebology 2000 15 : 126 30.
    • (2000) Phlebology , vol.15 , pp. 126-130
    • Häfner, H.M.1    Jünger, M.2
  • 3
    • 55949118732 scopus 로고    scopus 로고
    • European Committee for Standardization (CEN) Non-active medical devices. Working group 2 ENV 12718: European Prestandard 'Medical compression hosiery' CEN/TC205 Brussels: CEN
    • European Committee for Standardization (CEN) Non-active medical devices. Working group 2 ENV 12718: European Prestandard 'Medical compression hosiery' CEN/TC205 Brussels: CEN, 2001.
    • (2001)
  • 5
    • 33645063474 scopus 로고    scopus 로고
    • Measurement of lower leg compression in vivo: Recommendations for the performance of measurements of interface pressure and stiffness
    • Partsch H, Clark M, Bassez S, et al. Measurement of lower leg compression in vivo: recommendations for the performance of measurements of interface pressure and stiffness. Dermatol Surg 2006 32 : 224 33.
    • (2006) Dermatol Surg , vol.32 , pp. 224-233
    • Partsch, H.1    Clark, M.2    Bassez, S.3
  • 6
    • 33645074172 scopus 로고    scopus 로고
    • Calculating the pressure and the stiffness in three different categories of class II medical elastic compression stockings
    • Van der Wegen-Franken K, Roest W, Tank B, Neumann HAM. Calculating the pressure and the stiffness in three different categories of class II medical elastic compression stockings. Dermatol Surg 2006 32 : 216 23.
    • (2006) Dermatol Surg , vol.32 , pp. 216-223
    • Van Der Wegen-Franken, K.1    Roest, W.2    Tank, B.3    Neumann, H.A.M.4
  • 7
    • 2442548958 scopus 로고    scopus 로고
    • A method for measuring the dynamic behavior of medical compression hosiery during walking
    • Stolk R, van der Wegen-Franken CPM, Neumann HAM. A method for measuring the dynamic behavior of medical compression hosiery during walking. Dermatol Surg 2004 30 : 1 8.
    • (2004) Dermatol Surg , vol.30 , pp. 1-8
    • Stolk, R.1    Van Der Wegen-Franken, C.P.M.2    Neumann, H.A.M.3
  • 8
    • 0032880230 scopus 로고    scopus 로고
    • Inelastic leg compression is more effective to reduce deep venous refluxes than elastic bandages
    • Partsch H, Menzinger G, Mostbeck A. Inelastic leg compression is more effective to reduce deep venous refluxes than elastic bandages. Dermatol Surg 1999 25 : 695 700.
    • (1999) Dermatol Surg , vol.25 , pp. 695-700
    • Partsch, H.1    Menzinger, G.2    Mostbeck, A.3
  • 9
    • 0029861470 scopus 로고    scopus 로고
    • Inelastic versus elastic leg compression in chronic venous insufficiency: A comparison of limb size and venous haemodynamics
    • Spence RK, Cahall E. Inelastic versus elastic leg compression in chronic venous insufficiency: a comparison of limb size and venous haemodynamics. J Vasc Surg 1996 24 : 783 7.
    • (1996) J Vasc Surg , vol.24 , pp. 783-787
    • Spence, R.K.1    Cahall, E.2
  • 10
    • 22844451719 scopus 로고    scopus 로고
    • The static stiffness index: A simple method to assess the elastic property of compression material in vivo
    • Partsch H. The static stiffness index: a simple method to assess the elastic property of compression material in vivo. Dermatol Surg 2005 31 : 625 30.
    • (2005) Dermatol Surg , vol.31 , pp. 625-630
    • Partsch, H.1
  • 11
    • 55949124205 scopus 로고    scopus 로고
    • Compression stockings. Walking pressure and proposal of a dynamic stiffness index.(abstract)
    • Benigni JP, Cornu Thénard A, Uhl JF, Schadeck M. Compression stockings. Walking pressure and proposal of a dynamic stiffness index.(abstract). Int Angiol 2005 24 (Suppl 1) : 21.
    • (2005) Int Angiol , vol.24 , Issue.1 , pp. 21
    • Benigni, J.P.1    Cornu Thénard, A.2    Uhl, J.F.3    Schadeck, M.4
  • 12
    • 22844444944 scopus 로고    scopus 로고
    • Objective evaluation of skin pressure distribution of graduated elastic compression stockings
    • Liu R, Kwok YL, Li Y, et al. Objective evaluation of skin pressure distribution of graduated elastic compression stockings. Dermatol Surg 2005 31 : 615 24.
    • (2005) Dermatol Surg , vol.31 , pp. 615-624
    • Liu, R.1    Kwok, Y.L.2    Li, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.