메뉴 건너뛰기




Volumn 33, Issue SUPPL. 1, 2008, Pages

Self-sealing capacity of argillaceous rocks: Review of laboratory results obtained from the SELFRAC project

Author keywords

Boom Clay; EDZ; Opalinus Clay; Self sealing

Indexed keywords

DIAGNOSTIC RADIOGRAPHY; ELASTIC MODULI; ELECTRIC CONDUCTIVITY MEASUREMENT; ELECTRIC INSTRUMENT TRANSFORMERS; HYDRAULIC CONDUCTIVITY; HYDRAULICS; IMAGING SYSTEMS; IMAGING TECHNIQUES; MECHANICAL PROPERTIES; MEDICAL IMAGING; ROCK PRESSURE; STATISTICAL TESTS; TESTING; TOMOGRAPHY; WATER;

EID: 55949098406     PISSN: 14747065     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.pce.2008.10.063     Document Type: Article
Times cited : (58)

References (10)
  • 2
    • 33847741117 scopus 로고    scopus 로고
    • The excavation damaged zone in clay formations - time-dependent behaviour and influence on performance assessment
    • Blümling P., Bernier F., Lebon P., and Martin D.C. The excavation damaged zone in clay formations - time-dependent behaviour and influence on performance assessment. Physics and Chemistry of the Earth 32 (2007) 588-599
    • (2007) Physics and Chemistry of the Earth , vol.32 , pp. 588-599
    • Blümling, P.1    Bernier, F.2    Lebon, P.3    Martin, D.C.4
  • 3
    • 55949107495 scopus 로고    scopus 로고
    • Dierckx, A., 1997. Boom Clay in situ porewater chemistry, SCK•CEN Report, BLG-734.
    • Dierckx, A., 1997. Boom Clay in situ porewater chemistry, SCK•CEN Report, BLG-734.
  • 4
    • 0023783549 scopus 로고
    • A method for comparing beam-hardening filter materials for diagnostic radiology
    • Jennings R.J. A method for comparing beam-hardening filter materials for diagnostic radiology. Med. Phys. 15 (1988) 588-599
    • (1988) Med. Phys. , vol.15 , pp. 588-599
    • Jennings, R.J.1
  • 5
    • 0001235374 scopus 로고
    • Artefacts in computed tomography
    • Newton T.H., and Potts D.G. (Eds), The C.V. Mosby Company, St.-Louis, Illinois
    • Joseph P.M. Artefacts in computed tomography. In: Newton T.H., and Potts D.G. (Eds). Radiology of the skull and brain: technical aspects of computed tomography vol. 5 (1981), The C.V. Mosby Company, St.-Louis, Illinois 4058-4095
    • (1981) Radiology of the skull and brain: technical aspects of computed tomography , vol.5 , pp. 4058-4095
    • Joseph, P.M.1
  • 6
    • 55949097223 scopus 로고    scopus 로고
    • Pearson, F.J., Arcos, D., Bath, A., Boisson, J.-Y., Fernandez, A., Gaebler, H.-E., Gaucher, E., Gautschi, A., Griffault, L., Hernan, P., Waber, H.N., 2003. Geochemistry of water in the Opalinus Clay formation at the Mont Terri rock laboratory. Synthesis Report. Swiss National Hydrological and Geological Survey, Ittigen-Berne, Switzerland, Geological Report No. 5.
    • Pearson, F.J., Arcos, D., Bath, A., Boisson, J.-Y., Fernandez, A., Gaebler, H.-E., Gaucher, E., Gautschi, A., Griffault, L., Hernan, P., Waber, H.N., 2003. Geochemistry of water in the Opalinus Clay formation at the Mont Terri rock laboratory. Synthesis Report. Swiss National Hydrological and Geological Survey, Ittigen-Berne, Switzerland, Geological Report No. 5.
  • 7
    • 55949128660 scopus 로고    scopus 로고
    • Van Geet, M., 2001. Optimisation of microfocus X-ray computer tomography for geological research with special emphasis on coal components (macerals) and fractures (cleats) characterisation. PhD dissertation. K.U. Leuven, Faculteit Wetenschappen, Departement Geografie-Geologie, Leuven, Belgium, 203 p.
    • Van Geet, M., 2001. Optimisation of microfocus X-ray computer tomography for geological research with special emphasis on coal components (macerals) and fractures (cleats) characterisation. PhD dissertation. K.U. Leuven, Faculteit Wetenschappen, Departement Geografie-Geologie, Leuven, Belgium, 203 p.
  • 8
    • 0035447237 scopus 로고    scopus 로고
    • Quantitative 3D-fracture analysis by means of microfocus X-ray computer tomography (μCT): an example from coal
    • Van Geet M., and Swennen R. Quantitative 3D-fracture analysis by means of microfocus X-ray computer tomography (μCT): an example from coal. Geophys. Res. Lett. 28 17 (2001) 3333-3336
    • (2001) Geophys. Res. Lett. , vol.28 , Issue.17 , pp. 3333-3336
    • Van Geet, M.1    Swennen, R.2
  • 9
    • 0034093732 scopus 로고    scopus 로고
    • Quantitative analysis of reservoir rocks by means of microfocus X-ray computer tomography
    • Van Geet M., Swennen R., and Wevers M. Quantitative analysis of reservoir rocks by means of microfocus X-ray computer tomography. Sediment. Geol. 132 (2000) 25-36
    • (2000) Sediment. Geol. , vol.132 , pp. 25-36
    • Van Geet, M.1    Swennen, R.2    Wevers, M.3
  • 10
    • 55949117131 scopus 로고    scopus 로고
    • Volckaert, G., Ortiz, L., De Cannière, P., Put, M., Horseman, S.T., Harrington, J.F., Fioravante, V., Impey, M.D., 1995. MEGAS: modelling and experiments on gas migration in repository host rocks, Final Report - Phase 1, European Commission Report EUR 16235 EN.
    • Volckaert, G., Ortiz, L., De Cannière, P., Put, M., Horseman, S.T., Harrington, J.F., Fioravante, V., Impey, M.D., 1995. MEGAS: modelling and experiments on gas migration in repository host rocks, Final Report - Phase 1, European Commission Report EUR 16235 EN.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.