메뉴 건너뛰기




Volumn 114 PART 1, Issue , 2008, Pages 273-281

On-site experimental validation of a coupled multizone and CFD model for building contaminant transport simulations

Author keywords

[No Author keywords available]

Indexed keywords

AIR FLOWRATES; CALCULATION SPEEDS; CFD (COMPUTATIONAL FLUID DYNAMICS); CFD MODELS; COMPUTATION TIMES; COMPUTATIONAL TIMES; CONTAMINANT CONCENTRATIONS; CONTAMINANT DISTRIBUTIONS; CONTAMINANT SOURCES; CONTAMINANT TRANSPORTS; COUPLED MODELS; COUPLING METHODS; EXPERIMENTAL VALIDATIONS; FIELD EXPERIMENTS; MULTIZONE MODELS; NUMERICAL VALIDATIONS; OFFICE SPACES; VALIDATION METHODS;

EID: 55849123641     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (19)

References (14)
  • 3
    • 0035572682 scopus 로고    scopus 로고
    • Validation of multizone IAQ modeling of residential-scale buildings: A review
    • Emmerich, S.J. 2001. Validation of multizone IAQ modeling of residential-scale buildings: A review. ASHRAE Transactions 107(2).
    • (2001) ASHRAE Transactions , vol.107 , Issue.2
    • Emmerich, S.J.1
  • 5
    • 55849087444 scopus 로고    scopus 로고
    • Coupling of computational fluid dynamics and a multizone airflow analysis program for indoor environmental design. M.S. thesis. Massachusetts Institute of Technology, Cambridge, MA
    • Gao, Y. 2002. Coupling of computational fluid dynamics and a multizone airflow analysis program for indoor environmental design. M.S. thesis. Massachusetts Institute of Technology, Cambridge, MA.
    • (2002)
    • Gao, Y.1
  • 6
    • 55849148216 scopus 로고    scopus 로고
    • Indoor VOC source and sink modeling in multizone simulations of real buildings
    • paper no. 820, 11 pages, May 2-7, Toronto, Canada
    • Hu, H. and J. Srebric. 2004. Indoor VOC source and sink modeling in multizone simulations of real buildings, CIB World Building Congress 2004, CD ROM, paper no. 820, 11 pages, May 2-7, Toronto, Canada.
    • (2004) CIB World Building Congress 2004, CD ROM
    • Hu, H.1    Srebric, J.2
  • 7
    • 0034831396 scopus 로고    scopus 로고
    • An analysis of combined CFD and multi-zone IAQ model assembly issues
    • Musser, A. 2001. An analysis of combined CFD and multi-zone IAQ model assembly issues. ASHRAE Transactions 107(1).
    • (2001) ASHRAE Transactions , vol.107 , Issue.1
    • Musser, A.1
  • 9
    • 0027874254 scopus 로고
    • Improvement of multizone model prediction by detailed flow path values from CFD calculations
    • DE-93-7-4, pp
    • Schaelin, A., V. Dorer, J. van der Mass, and A. Moser. 1993. Improvement of multizone model prediction by detailed flow path values from CFD calculations. ASHRAE Transactions DE-93-7-4, pp. 709-720.
    • (1993) ASHRAE Transactions , pp. 709-720
    • Schaelin, A.1    Dorer, V.2    van der Mass, J.3    Moser, A.4
  • 10
    • 0003660977 scopus 로고    scopus 로고
    • CONTAMW2.0 user manual. National Institute of Standards and Technology (NIST)
    • November, 162 pages
    • Dols, W.S. and G.N. Walton. 2002. CONTAMW2.0 user manual. National Institute of Standards and Technology (NIST), NISTIR 6921, November, 162 pages.
    • (2002) NISTIR , vol.6921
    • Dols, W.S.1    Walton, G.N.2
  • 11
    • 78249236229 scopus 로고    scopus 로고
    • Improved prediction of indoor contaminant distribution for the entire buildings
    • New Orleans, IMECE
    • Yuan, J. and J. Srebric. 2002. Improved prediction of indoor contaminant distribution for the entire buildings. ASME Winter Meeting 2002, New Orleans, IMECE 33860.
    • (2002) ASME Winter Meeting 2002 , pp. 33860
    • Yuan, J.1    Srebric, J.2
  • 12
    • 45749148521 scopus 로고    scopus 로고
    • Transient prediction of contaminant distribution by introducing energy load calculations into multi-zone modeling
    • CD ROM, paper no. 148, 11 pages. May 2-7, Toronto, Canada
    • Yuan, J. and J. Srebric. 2004. Transient prediction of contaminant distribution by introducing energy load calculations into multi-zone modeling. CIB World Building Congress 2004, CD ROM, paper no. 148, 11 pages. May 2-7, Toronto, Canada.
    • (2004) CIB World Building Congress 2004
    • Yuan, J.1    Srebric, J.2
  • 13
    • 0029215096 scopus 로고
    • Simulation and measurement of air infiltration and pollutant transport using a passive solar test house
    • Yoshino, H., Z. Yun, H. Kobayashi, and Y. Utsumi. 1995. Simulation and measurement of air infiltration and pollutant transport using a passive solar test house. ASHRAE Transactions 101(1): 1091-1099.
    • (1995) ASHRAE Transactions , vol.101 , Issue.1 , pp. 1091-1099
    • Yoshino, H.1    Yun, Z.2    Kobayashi, H.3    Utsumi, Y.4
  • 14
    • 34247544296 scopus 로고    scopus 로고
    • Validation of a coupled multizone-CFD program for building airflow and contaminant transport simulations
    • March, pp
    • Wang, L. and Q. Chen, 2007. Validation of a coupled multizone-CFD program for building airflow and contaminant transport simulations. HVAC and R Research, v 13, n 2, March, pp. 267-281.
    • (2007) HVAC and R Research , vol.13 , Issue.2 , pp. 267-281
    • Wang, L.1    Chen, Q.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.