메뉴 건너뛰기




Volumn 39, Issue 11, 2008, Pages 3003-3008

Assessment of the contribution of the external carotid artery to brain perfusion in patients with internal carotid artery occlusion

Author keywords

Carotid artery occlusion; Cerebral hemodynamics; Collateral circulation; Magnetic resonance imaging

Indexed keywords

ADULT; ANGIOGRAPHY; ANTERIOR CEREBRAL ARTERY; ARTICLE; BRAIN BLOOD FLOW; BRAIN PERFUSION; BRAIN REGION; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CLINICAL TRIAL; COLLATERAL CIRCULATION; DIGITAL SUBTRACTION ANGIOGRAPHY; DISEASE SEVERITY; EXTERNAL CAROTID ARTERY; FEMALE; HUMAN; INTERNAL CAROTID ARTERY OCCLUSION; MALE; MIDDLE CEREBRAL ARTERY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROSPECTIVE STUDY; TRANSIENT ISCHEMIC ATTACK; AGED; BLOOD FLOW; BRAIN CIRCULATION; CAROTID ARTERY DISEASE; COMMON CAROTID ARTERY; INTERNAL CAROTID ARTERY; METABOLISM; MIDDLE AGED; PATHOLOGY; PERIPHERAL OCCLUSIVE ARTERY DISEASE; SPIN LABELING;

EID: 55749094335     PISSN: 00392499     EISSN: None     Source Type: Journal    
DOI: 10.1161/STROKEAHA.108.514265     Document Type: Article
Times cited : (73)

References (39)
  • 1
    • 0026063830 scopus 로고
    • Cerebral hemodynamics in ischemic cerebrovascular disease
    • Powers WJ. Cerebral hemodynamics in ischemic cerebrovascular disease. Ann Neurol. 1991;29:231-240.
    • (1991) Ann Neurol , vol.29 , pp. 231-240
    • Powers, W.J.1
  • 2
    • 0042919302 scopus 로고    scopus 로고
    • Collateral circulation
    • Liebeskind DS. Collateral circulation. Stroke. 2003;34:2279 -2284.
    • (2003) Stroke , vol.34 , pp. 2279-2284
    • Liebeskind, D.S.1
  • 3
    • 0031858082 scopus 로고    scopus 로고
    • Role of collateral flow on cerebral hemodynamics in patients with unilateral internal carotid artery occlusion
    • van Everdingen KJ, Visser GH, Klijn CJM, Kappelle LJ, van der Grond J. Role of collateral flow on cerebral hemodynamics in patients with unilateral internal carotid artery occlusion. Ann Neurol. 1998;44: 167-176.
    • (1998) Ann Neurol , vol.44 , pp. 167-176
    • van Everdingen, K.J.1    Visser, G.H.2    Klijn, C.J.M.3    Kappelle, L.J.4    van der Grond, J.5
  • 5
    • 33646825776 scopus 로고    scopus 로고
    • No evidence that severity of stroke in internal carotid occlusion is related to collateral arteries
    • Mead GE, Wardlaw JM, Lewis SC, Dennis MS. No evidence that severity of stroke in internal carotid occlusion is related to collateral arteries. J Neurol Neurosurg Psychiatry. 2006;77:729-733.
    • (2006) J Neurol Neurosurg Psychiatry , vol.77 , pp. 729-733
    • Mead, G.E.1    Wardlaw, J.M.2    Lewis, S.C.3    Dennis, M.S.4
  • 6
    • 0030063653 scopus 로고    scopus 로고
    • Vasomotor reactivity and pattern of collateral blood flow in severe occlusive carotid artery disease
    • Muller M, Schimrigk K. Vasomotor reactivity and pattern of collateral blood flow in severe occlusive carotid artery disease. Stroke. 1996;27: 296-299.
    • (1996) Stroke , vol.27 , pp. 296-299
    • Muller, M.1    Schimrigk, K.2
  • 8
    • 2542537722 scopus 로고    scopus 로고
    • Recurrent stroke in patients with symptomatic carotid artery occlusion is associated with high-volume flow to the brain and increased collateral circulation
    • Rutgers DR, Klijn CJ, Kappelle LJ, van der Grond J. Recurrent stroke in patients with symptomatic carotid artery occlusion is associated with high-volume flow to the brain and increased collateral circulation. Stroke. 2004;35:1345-1349.
    • (2004) Stroke , vol.35 , pp. 1345-1349
    • Rutgers, D.R.1    Klijn, C.J.2    Kappelle, L.J.3    van der Grond, J.4
  • 9
    • 0033971337 scopus 로고    scopus 로고
    • Angio-graphically defined collateral circulation and risk of stroke in patients with severe carotid artery stenosis
    • Henderson RD, Eliasziw M, Fox AJ, Rothwell PM, Barnett HJM. Angio-graphically defined collateral circulation and risk of stroke in patients with severe carotid artery stenosis. Stroke. 2000;31:128 -132.
    • (2000) Stroke , vol.31 , pp. 128-132
    • Henderson, R.D.1    Eliasziw, M.2    Fox, A.J.3    Rothwell, P.M.4    Barnett, H.J.M.5
  • 10
    • 1842418806 scopus 로고    scopus 로고
    • Flow territory mapping of the cerebral arteries with regional perfusion MRI
    • Hendrikse J, van der Grond J, Lu H, van Zijl PC, Golay X. Flow territory mapping of the cerebral arteries with regional perfusion MRI. Stroke. 2004;35:882-887.
    • (2004) Stroke , vol.35 , pp. 882-887
    • Hendrikse, J.1    van der Grond, J.2    Lu, H.3    van Zijl, P.C.4    Golay, X.5
  • 11
    • 0024687877 scopus 로고
    • Interobserver agreement for the assessment of handicap in stroke patients
    • Bamford JM, Sandercock PAG, Warlow CP, Slattery J. Interobserver agreement for the assessment of handicap in stroke patients. Stroke. 1989;20:828.
    • (1989) Stroke , vol.20 , pp. 828
    • Bamford, J.M.1    Sandercock, P.A.G.2    Warlow, C.P.3    Slattery, J.4
  • 12
    • 0032904710 scopus 로고    scopus 로고
    • Transfer insensitive labeling technique (TILT): Application to multislice functional perfusion imaging
    • Golay X, Stuber M, Pruessmann KP, Meier D, Boesiger P. Transfer insensitive labeling technique (TILT): application to multislice functional perfusion imaging. J Magn Reson Imaging. 1999;9:454-461.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 454-461
    • Golay, X.1    Stuber, M.2    Pruessmann, K.P.3    Meier, D.4    Boesiger, P.5
  • 15
    • 32544441071 scopus 로고    scopus 로고
    • Model-free arterial spin labeling quantification approach for perfusion MRI
    • 55L219-232
    • Petersen ET, Lim T, Golay X. Model-free arterial spin labeling quantification approach for perfusion MRI. Magn Res Med. 2006;55L219-232.
    • (2006) Magn Res Med
    • Petersen, E.T.1    Lim, T.2    Golay, X.3
  • 17
    • 0041590974 scopus 로고    scopus 로고
    • Measurements of cerebral perfusion and arterial hemodynamics during visual stimulation using TURBO-TILT
    • Hendrikse J, Lu H, van der Grond J, van Zijl PC, Golay X. Measurements of cerebral perfusion and arterial hemodynamics during visual stimulation using TURBO-TILT. Magn Reson Med. 2003;50:429-433.
    • (2003) Magn Reson Med , vol.50 , pp. 429-433
    • Hendrikse, J.1    Lu, H.2    van der Grond, J.3    van Zijl, P.C.4    Golay, X.5
  • 19
    • 0033933649 scopus 로고    scopus 로고
    • Voxel-based morphometry - the methods
    • Ashburner J, Friston KJ. Voxel-based morphometry - the methods. Neuroimage. 2000;11:805-821.
    • (2000) Neuroimage , vol.11 , pp. 805-821
    • Ashburner, J.1    Friston, K.J.2
  • 21
    • 0034757715 scopus 로고    scopus 로고
    • Arterial spin labeling in combination with a look-locker sampling strategy: Inflow turbo-sampling EPI-FAIR (ITS-FAIR)
    • Gunther M, Bock M, Schad LR. Arterial spin labeling in combination with a look-locker sampling strategy: inflow turbo-sampling EPI-FAIR (ITS-FAIR). Magn Reson Med. 2001;46:974-984.
    • (2001) Magn Reson Med , vol.46 , pp. 974-984
    • Gunther, M.1    Bock, M.2    Schad, L.R.3
  • 22
    • 4243184848 scopus 로고    scopus 로고
    • Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
    • Lu H, Clingman C, Golay X, van Zijl PC. Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med. 2004;52: 679-682.
    • (2004) Magn Reson Med , vol.52 , pp. 679-682
    • Lu, H.1    Clingman, C.2    Golay, X.3    van Zijl, P.C.4
  • 23
    • 0033858794 scopus 로고    scopus 로고
    • A longitudinal study of collateral flow patterns in the circle of Willis and the ophthalmic artery in patients with a symptomatic internal carotid artery occlusion
    • Rutgers DR, Klijn CJM, Kappelle LJ, van Huffelen AC, van der Grond J. A longitudinal study of collateral flow patterns in the circle of Willis and the ophthalmic artery in patients with a symptomatic internal carotid artery occlusion. Stroke. 2000;31:1913-1920.
    • (2000) Stroke , vol.31 , pp. 1913-1920
    • Rutgers, D.R.1    Klijn, C.J.M.2    Kappelle, L.J.3    van Huffelen, A.C.4    van der Grond, J.5
  • 26
    • 0028961859 scopus 로고
    • NMR measurement of perfusion using arterial spin labeling without saturation of macromo-lecular spins
    • Zhang W, Silva AC, Williams DS, Koretsky AP. NMR measurement of perfusion using arterial spin labeling without saturation of macromo-lecular spins. Magn Reson Med. 1995;33:370-376.
    • (1995) Magn Reson Med , vol.33 , pp. 370-376
    • Zhang, W.1    Silva, A.C.2    Williams, D.S.3    Koretsky, A.P.4
  • 27
    • 0033033852 scopus 로고    scopus 로고
    • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
    • Zaharchuk G, Ledden PJ, Kwong KK, Reese TG, Rosen BR, Wald LL. Multislice perfusion and perfusion territory imaging in humans with separate label and image coils. Magn Reson Med. 1999;41:1093-1098.
    • (1999) Magn Reson Med , vol.41 , pp. 1093-1098
    • Zaharchuk, G.1    Ledden, P.J.2    Kwong, K.K.3    Reese, T.G.4    Rosen, B.R.5    Wald, L.L.6
  • 29
    • 36849056529 scopus 로고    scopus 로고
    • Vessel encoded arterial spin labeling using pseudo-continuous tagging
    • Wong EC. Vessel encoded arterial spin labeling using pseudo-continuous tagging. Magn Reson Med. 2007;58:1086-1091.
    • (2007) Magn Reson Med , vol.58 , pp. 1086-1091
    • Wong, E.C.1
  • 30
    • 0037764001 scopus 로고    scopus 로고
    • Selective arterial spin labeling (SASL): Perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses
    • Davies NP, Jezzard P. Selective arterial spin labeling (SASL): perfusion territory mapping of selected feeding arteries tagged using two-dimensional radiofrequency pulses. Magn Reson Med. 2003;49: 1133-1142.
    • (2003) Magn Reson Med , vol.49 , pp. 1133-1142
    • Davies, N.P.1    Jezzard, P.2
  • 32
    • 12144281348 scopus 로고    scopus 로고
    • Pulsed star labeling of arterial regions (PULSAR): A robust regional perfusion technique for high field imaging
    • Golay X, Petersen ET, Hui F. Pulsed star labeling of arterial regions (PULSAR): a robust regional perfusion technique for high field imaging. Magn Reson Med. 2005;53:15-21.
    • (2005) Magn Reson Med , vol.53 , pp. 15-21
    • Golay, X.1    Petersen, E.T.2    Hui, F.3
  • 33
    • 1242316372 scopus 로고    scopus 로고
    • Distinguishing between anterior cerebral artery and middle cerebral artery perfusion by color-coded perfusion direction mapping with arterial spin labeling
    • Taoka T, Iwasaki S, Nakagawa H, Nakagawa H, Fukusumi A, Hirohashi S, Sakmoto M, Kichikawa K, Murata K. Distinguishing between anterior cerebral artery and middle cerebral artery perfusion by color-coded perfusion direction mapping with arterial spin labeling. AJNR Am J Neuroradiol. 2004;25:248-251.
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 248-251
    • Taoka, T.1    Iwasaki, S.2    Nakagawa, H.3    Nakagawa, H.4    Fukusumi, A.5    Hirohashi, S.6    Sakmoto, M.7    Kichikawa, K.8    Murata, K.9
  • 34
    • 0030664472 scopus 로고    scopus 로고
    • Symptomatic carotid artery occlusion. A reappraisal of hemodynamic factors
    • Klijn CJM, Kappelle LJ, Tulleken CAF, van Gijn J. Symptomatic carotid artery occlusion. A reappraisal of hemodynamic factors. Stroke. 1997;28: 2084-2093.
    • (1997) Stroke , vol.28 , pp. 2084-2093
    • Klijn, C.J.M.1    Kappelle, L.J.2    Tulleken, C.A.F.3    van Gijn, J.4
  • 35
    • 16544372976 scopus 로고    scopus 로고
    • Internal carotid artery occlusion assessed at pulsed arterial spin-labeling perfusion MR imaging at multiple delay times
    • Hendrikse J, van Osch MJ, Rutgers DR, Bakker CJ, Kappelle LJ, Golay X, van der Grond J. Internal carotid artery occlusion assessed at pulsed arterial spin-labeling perfusion MR imaging at multiple delay times. Radiology. 2004;233:899-904.
    • (2004) Radiology , vol.233 , pp. 899-904
    • Hendrikse, J.1    van Osch, M.J.2    Rutgers, D.R.3    Bakker, C.J.4    Kappelle, L.J.5    Golay, X.6    van der Grond, J.7
  • 36
    • 0031848388 scopus 로고    scopus 로고
    • A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging
    • Wong EC, Buxton RB, Frank LR. A theoretical and experimental comparison of continuous and pulsed arterial spin labeling techniques for quantitative perfusion imaging. Magn Reson Med. 1998;40:348-355.
    • (1998) Magn Reson Med , vol.40 , pp. 348-355
    • Wong, E.C.1    Buxton, R.B.2    Frank, L.R.3
  • 37
    • 0032997648 scopus 로고    scopus 로고
    • QUIPSS II with thin-slice TI1 periodic saturation: A method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling
    • Luh WM, Wong EC, Bandettini PA, Hyde JS. QUIPSS II with thin-slice TI1 periodic saturation: a method for improving accuracy of quantitative perfusion imaging using pulsed arterial spin labeling. Magn Reson Med. 1999;41:1246-1254.
    • (1999) Magn Reson Med , vol.41 , pp. 1246-1254
    • Luh, W.M.1    Wong, E.C.2    Bandettini, P.A.3    Hyde, J.S.4
  • 39
    • 0031022848 scopus 로고    scopus 로고
    • Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
    • Ye FQ, Mattay VS, Jezzard P, Frank JA, Weinberger DR, McLaughlin AC. Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques. Magn Reson Med. 1997;37:226-235.
    • (1997) Magn Reson Med , vol.37 , pp. 226-235
    • Ye, F.Q.1    Mattay, V.S.2    Jezzard, P.3    Frank, J.A.4    Weinberger, D.R.5    McLaughlin, A.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.