메뉴 건너뛰기




Volumn 191, Issue 5, 2008, Pages 1386-1390

Does dual-energy CT of lower-extremity tendons incur penalties in patient radiation exposure or reduced multiplanar reconstruction image quality?

Author keywords

Dual energy CT; Ionizing radiation; Tendon

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTER ASSISTED DIAGNOSIS; CONTROLLED STUDY; DUAL ENERGY COMPUTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE RECONSTRUCTION; LEG; MALE; NORMAL HUMAN; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; RADIATION DOSE; RADIATION EXPOSURE; SIGNAL NOISE RATIO; TENDON;

EID: 55549103694     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.07.3624     Document Type: Article
Times cited : (18)

References (13)
  • 1
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr TG, McCollough CH, Bruder H, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006; 16:256-268
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 2
    • 38449089116 scopus 로고    scopus 로고
    • Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease
    • Johnson TR, Nikolaou K, Busch S, et al. Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest Radiol 2007; 42:684-691
    • (2007) Invest Radiol , vol.42 , pp. 684-691
    • Johnson, T.R.1    Nikolaou, K.2    Busch, S.3
  • 3
    • 36448991889 scopus 로고    scopus 로고
    • Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT
    • Seifarth J, Wienbeck S, Pusken M, et al. Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT. AJR 2007; 189:1317-1323
    • (2007) AJR , vol.189 , pp. 1317-1323
    • Seifarth, J.1    Wienbeck, S.2    Pusken, M.3
  • 4
    • 0017693719 scopus 로고
    • Selective iodine imaging using k-edge energies in computerized x-ray tomography
    • Riederer SJ, Mistretta CA. Selective iodine imaging using k-edge energies in computerized x-ray tomography. Med Phys 1977; 4:474-481
    • (1977) Med Phys , vol.4 , pp. 474-481
    • Riederer, S.J.1    Mistretta, C.A.2
  • 5
    • 34248673159 scopus 로고    scopus 로고
    • Material differentiation by dual energy CT: Initial experience
    • Johnson TR, Krauss B, Sedlmair M, et al. Material differentiation by dual energy CT: initial experience. Eur Radiol 2007; 17:1510-1517
    • (2007) Eur Radiol , vol.17 , pp. 1510-1517
    • Johnson, T.R.1    Krauss, B.2    Sedlmair, M.3
  • 6
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission x-ray computed tomography
    • Shope TB, Gagne RM, Johnson GC. A method for describing the doses delivered by transmission x-ray computed tomography. Med Phys 1981; 8:488-495
    • (1981) Med Phys , vol.8 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 7
    • 0017604035 scopus 로고
    • Quantitative bone mineral analysis using dual energy computed tomography
    • Genant HK, Boyd D. Quantitative bone mineral analysis using dual energy computed tomography. Invest Radiol 1977; 12:545-551
    • (1977) Invest Radiol , vol.12 , pp. 545-551
    • Genant, H.K.1    Boyd, D.2
  • 8
    • 0020073618 scopus 로고
    • Measurement of trabecular bone mineral by dual energy computed tomography
    • Adams JE, Chen SZ, Adams PH, Isherwood I. Measurement of trabecular bone mineral by dual energy computed tomography. J Comput Assist Tomogr 1982; 6:601-607
    • (1982) J Comput Assist Tomogr , vol.6 , pp. 601-607
    • Adams, J.E.1    Chen, S.Z.2    Adams, P.H.3    Isherwood, I.4
  • 10
    • 0021267364 scopus 로고
    • Some practical aspects of dual-energy CT scanning
    • Dunscombe PB, Katz DE, Stacey AJ. Some practical aspects of dual-energy CT scanning. Br J Radiol 1984; 57:82-87
    • (1984) Br J Radiol , vol.57 , pp. 82-87
    • Dunscombe, P.B.1    Katz, D.E.2    Stacey, A.J.3
  • 11
    • 0032080136 scopus 로고    scopus 로고
    • Dual-energy CT in the diagnosis and quantification of fatty liver: Limited clinical value in comparison to ultrasound scan and single-energy CT, with special reference to iron overload
    • Mendler MH, Bouillet P, Le Sidaner A, et al. Dual-energy CT in the diagnosis and quantification of fatty liver: limited clinical value in comparison to ultrasound scan and single-energy CT, with special reference to iron overload. J Hepatol 1998; 28:785-794
    • (1998) J Hepatol , vol.28 , pp. 785-794
    • Mendler, M.H.1    Bouillet, P.2    Le Sidaner, A.3
  • 12
    • 0034311808 scopus 로고    scopus 로고
    • Data explosion: The challenge of multidetector-row CT
    • Rubin GD. Data explosion: the challenge of multidetector-row CT. Eur J Radiol 2000; 36:74-80
    • (2000) Eur J Radiol , vol.36 , pp. 74-80
    • Rubin, G.D.1
  • 13
    • 36248997114 scopus 로고    scopus 로고
    • Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease
    • Scheffel H, Stolzmann P, Frauenfelder T, et al. Dual-energy contrast-enhanced computed tomography for the detection of urinary stone disease. Invest Radiol 2007; 42:823-829
    • (2007) Invest Radiol , vol.42 , pp. 823-829
    • Scheffel, H.1    Stolzmann, P.2    Frauenfelder, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.