메뉴 건너뛰기




Volumn 1301, Issue , 1997, Pages 199-210

The importance of fatigue loading when assessing liner/shell distraction resistance and congruency for modular acetabular components

Author keywords

Acetabular cup; Implant; Modular; Prosthesis; THA; Total hip arthroplasty

Indexed keywords


EID: 5544275658     PISSN: 00660558     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1520/stp12033s     Document Type: Article
Times cited : (1)

References (7)
  • 2
    • 0025948335 scopus 로고
    • Disassembly of a One-Piece Metal-Backed Acetabular Component, A Case Report
    • November
    • Beaver, R. J., Schemitsch, E. H., and Gross, A. E., "Disassembly of a One-Piece Metal-Backed Acetabular Component, A Case Report," The Journal of Bone and Joint Surgery, Vol. 73-B, No. 6, November 1991, pp. 908-910.
    • (1991) The Journal of Bone and Joint Surgery , vol.73 B , Issue.6 , pp. 908-910
    • Beaver, R.J.1    Schemitsch, E.H.2    Gross, A.E.3
  • 3
    • 0024551056 scopus 로고
    • Dissociation of a Metal-backed Polyethylene Acetabular Component
    • March
    • Bueche, M. J., Herzenberg, J. E., and Stubbs, B. T., "Dissociation of a Metal-backed Polyethylene Acetabular Component," The Journal of Arthroplasty, Vol. 4 No. 1, March 1989, pp. 39-41.
    • (1989) The Journal of Arthroplasty , vol.4 , Issue.1 , pp. 39-41
    • Bueche, M.J.1    Herzenberg, J.E.2    Stubbs, B.T.3
  • 4
    • 0025319780 scopus 로고
    • Disassembly of a Modular Acetabular Component of a Total Hip-Replacement Arthroplasty
    • April
    • Kitziger, K. J., DeLee, J. C., and Evans, J. A., "Disassembly of a Modular Acetabular Component of a Total Hip-Replacement Arthroplasty," The Journal of Bone and Joint Surgery, Vol. 72-A, No. 4, April 1990, pp. 621-623.
    • (1990) The Journal of Bone and Joint Surgery , vol.72 A , Issue.4 , pp. 621-623
    • Kitziger, K.J.1    DeLee, J.C.2    Evans, J.A.3
  • 5
    • 0026442786 scopus 로고
    • The Harris-Galante Porous-Coated Acetabular Component with Screw Fixation
    • September
    • Schmalzried, T. P., and Harris, W. H., "The Harris-Galante Porous-Coated Acetabular Component with Screw Fixation," The Journal of Bone and Joint Surgery, Vol. 74-A, No. 8, September 1992, pp. 1130-1139.
    • (1992) The Journal of Bone and Joint Surgery , vol.74 A , Issue.8 , pp. 1130-1139
    • Schmalzried, T.P.1    Harris, W.H.2
  • 6
    • 0026544918 scopus 로고
    • Dissociation of Modular Hip Arthroplasty Components after Dislocation, A Report of Three Cases at Differing Dissociation Levels
    • May
    • Star, M. J., Colwell, C. W., Donaldson, W. P., and Walker, R. H., "Dissociation of Modular Hip Arthroplasty Components After Dislocation, A Report of Three Cases at Differing Dissociation Levels," Clinical Orthopaedics and Related Research, No. 278, May 1992, pp. 111-115.
    • (1992) Clinical Orthopaedics and Related Research , Issue.278 , pp. 111-115
    • Star, M.J.1    Colwell, C.W.2    Donaldson, W.P.3    Walker, R.H.4