Volumn 112, Issue 2, 2008, Pages 107-113

Long-term follow-up of patients with relatively high effective defibrillation threshold during cardioverter defibrillator implantation with endocardial leads

Author keywords

Defibrillation efficacy evaluation; Defibrillation threshold; Implantable cardioverter defibrillator

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DEFIBRILLATION; DEFIBRILLATION THRESHOLD; DEFIBRILLATOR; ENDOCARDIUM; FEMALE; FOLLOW UP; HEART PACING; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; MAJOR CLINICAL STUDY; MALE; OUTCOME ASSESSMENT; PATIENT SAFETY; PRIORITY JOURNAL; SURVIVAL;

EID: 55349104568     PISSN: 00086312     EISSN: None     Source Type: Journal    
DOI: 10.1159/000141463     Document Type: Article
Times cited : (3)

References (27)
  • 2
    • 0021808604 scopus 로고
    • The automatic implantable cardioverter-defibrillator
    • Mirowski M: The automatic implantable cardioverter-defibrillator. J Am Coll Cardiol 1985;6:461-466.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 461-466
    • Mirowski, M.1
  • 3
    • 0034610261 scopus 로고    scopus 로고
    • The role of implantable cardioverter-defibrillator for prevention of sudden cardiac death
    • Josephson ME, Callans DJ, Buxton AE: The role of implantable cardioverter-defibrillator for prevention of sudden cardiac death. Ann Intern Med 2000;133:901-910.
    • (2000) Ann Intern Med , vol.133 , pp. 901-910
    • Josephson, M.E.1    Callans, D.J.2    Buxton, A.E.3
  • 4
    • 32644436695 scopus 로고    scopus 로고
    • Implantable cardioverter-defibrillators. Expending indications and technology
    • Goldberger Z, Lampert R: Implantable cardioverter-defibrillators. Expending indications and technology. JAMA 2006;295:809-818.
    • (2006) JAMA , vol.295 , pp. 809-818
    • Goldberger, Z.1    Lampert, R.2
  • 6
    • 33745482583 scopus 로고    scopus 로고
    • A unique historical overview of the implantable cardioverter-defibrillator
    • Myerburg RJ, Castellanos A: A unique historical overview of the implantable cardioverter-defibrillator. Heart Rhythm 2006;3:169-170.
    • (2006) Heart Rhythm , vol.3 , pp. 169-170
    • Myerburg, R.J.1    Castellanos, A.2
  • 7
    • 0024448644 scopus 로고
    • A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in human
    • Bardy GH, Ivey TD, Allen MD, Johnson G, Mehra R, Greene HL: A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in human. J Am Coll Cardiol 1989;14:728-733.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 728-733
    • Bardy, G.H.1    Ivey, T.D.2    Allen, M.D.3    Johnson, G.4    Mehra, R.5    Greene, H.L.6
  • 8
    • 0033545682 scopus 로고    scopus 로고
    • A preview of implantable cardioverter defibrillator systems in the next millennium; an integrative cardiac rhythm management approach
    • Morris MM, KenKnight BH, Warren JA, Lang DJ: A preview of implantable cardioverter defibrillator systems in the next millennium; an integrative cardiac rhythm management approach. Am J Cardiol 1999;83:49D-54D.
    • (1999) Am J Cardiol , vol.83
    • Morris, M.M.1    KenKnight, B.H.2    Warren, J.A.3    Lang, D.J.4
  • 10
    • 0030237562 scopus 로고    scopus 로고
    • Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system
    • Gold MR, Foster AH, Shorofsky SR: Effects of an active pectoral-pulse generator shell on defibrillation efficacy with a transvenous lead system. Am J Cardiol 1996;78:540-543.
    • (1996) Am J Cardiol , vol.78 , pp. 540-543
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 11
    • 0028047664 scopus 로고
    • Rise in chronic defibrillation thresholds in nonthoracotomy implantable defibrillator
    • Venditti FJ, Martin DT, Vassolas G, Bowen S: Rise in chronic defibrillation thresholds in nonthoracotomy implantable defibrillator. Circulation 1994;89:216-223.
    • (1994) Circulation , vol.89 , pp. 216-223
    • Venditti, F.J.1    Martin, D.T.2    Vassolas, G.3    Bowen, S.4
  • 12
    • 0037245915 scopus 로고    scopus 로고
    • High defibrillation threshold in transvenous biphasic implantable defibrillators: Clinical predictors and prognostic implications
    • Shukla HH, Flaker GC, Jayam V, Roberts D: High defibrillation threshold in transvenous biphasic implantable defibrillators: clinical predictors and prognostic implications. Pacing Clin Electrophysiol 2003;26:44-48.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 44-48
    • Shukla, H.H.1    Flaker, G.C.2    Jayam, V.3    Roberts, D.4
  • 13
    • 33645875869 scopus 로고    scopus 로고
    • How to manage the patient with high defibrillation threshold
    • Mainigi SK, Callans DJ: How to manage the patient with high defibrillation threshold. Heart Rhythm 2006;3:492-495.
    • (2006) Heart Rhythm , vol.3 , pp. 492-495
    • Mainigi, S.K.1    Callans, D.J.2
  • 15
    • 34248162434 scopus 로고    scopus 로고
    • Induction or limited shock testing is possible in most patients with implantable cardioverter-defibrillator/ cardiac resynchronization therapy defibrillators. Results of a multicenter ASSURE study
    • Day JD, Doshi RN, Bellot P, et al: Induction or limited shock testing is possible in most patients with implantable cardioverter-defibrillator/ cardiac resynchronization therapy defibrillators. Results of a multicenter ASSURE study. Circulation 2007;115:2382-2389.
    • (2007) Circulation , vol.115 , pp. 2382-2389
    • Day, J.D.1    Doshi, R.N.2    Bellot, P.3
  • 16
    • 3242794231 scopus 로고    scopus 로고
    • Is defibrillation testing required for defibrillator implantation?
    • Strickberger SA, Klein GJ: Is defibrillation testing required for defibrillator implantation? J Am Coll Cardiol 2004;44:88-91.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 88-91
    • Strickberger, S.A.1    Klein, G.J.2
  • 18
    • 0033545589 scopus 로고    scopus 로고
    • Energy levels for defibrillation: What is of real clinical importance?
    • Fotuhi PC, Epstein AE, Ideker RE: Energy levels for defibrillation: what is of real clinical importance? Am J Cardiol 1999;83:24D-33D.
    • (1999) Am J Cardiol , vol.83
    • Fotuhi, P.C.1    Epstein, A.E.2    Ideker, R.E.3
  • 19
    • 0001913657 scopus 로고    scopus 로고
    • Testing of implantable defibrillator function at implantation
    • Ellenbogen KA, Kay GN, Wilkoff BC eds, ed 2. Philadelphia, WB Saunders
    • Kroll MW, Tchou PJ: Testing of implantable defibrillator function at implantation; in Ellenbogen KA, Kay GN, Wilkoff BC (eds): Clinical Cardiac Pacing and Defibrillation, ed 2. Philadelphia, WB Saunders, 2000, pp 540-561.
    • (2000) Clinical Cardiac Pacing and Defibrillation , pp. 540-561
    • Kroll, M.W.1    Tchou, P.J.2
  • 20
    • 1542588563 scopus 로고
    • The automatic implantable cardioverter defibrillator: The US experience
    • Brugada P, Wellens HJJ eds, New York, Futura Publishing Co Inc
    • Winkle RA, Thomas A: The automatic implantable cardioverter defibrillator: the US experience; in Brugada P, Wellens HJJ (eds): Cardiac Arrhythmias: Where to Go from Here? New York, Futura Publishing Co Inc, 1987, pp 663-680.
    • (1987) Cardiac Arrhythmias: Where to Go from Here , pp. 663-680
    • Winkle, R.A.1    Thomas, A.2
  • 21
    • 0025611528 scopus 로고
    • Current status of antitachycardia devices
    • Rosenthal ME, Josephson ME: Current status of antitachycardia devices. Circulation 1990;82:1889-1899.
    • (1990) Circulation , vol.82 , pp. 1889-1899
    • Rosenthal, M.E.1    Josephson, M.E.2
  • 22
    • 0023704188 scopus 로고
    • Implantation of a cardioverter/defibrillator without thoracotomy using a triple electrode system
    • Saksena S, Personnet V: Implantation of a cardioverter/defibrillator without thoracotomy using a triple electrode system. JAMA 1988;259:69-72.
    • (1988) JAMA , vol.259 , pp. 69-72
    • Saksena, S.1    Personnet, V.2
  • 23
    • 0026531999 scopus 로고
    • A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation
    • Yee R, Klein GJ, Leitch JW, Guiraudon GM, Guiraudon CM, Jones DL, Norris C: A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation. Circulation 1992;85:196-204.
    • (1992) Circulation , vol.85 , pp. 196-204
    • Yee, R.1    Klein, G.J.2    Leitch, J.W.3    Guiraudon, G.M.4    Guiraudon, C.M.5    Jones, D.L.6    Norris, C.7
  • 24
    • 0023786718 scopus 로고    scopus 로고
    • Marchlinski FE, Flores B, Miller JM, Gottlieb CD, Hargrove WC 3rd: Relation of intraoperative defibrillation threshold to successful postoperative defibrillation with automatic implantable cardioverter defibrillator. Am J Cardiol 1988;62:393-398.
    • Marchlinski FE, Flores B, Miller JM, Gottlieb CD, Hargrove WC 3rd: Relation of intraoperative defibrillation threshold to successful postoperative defibrillation with automatic implantable cardioverter defibrillator. Am J Cardiol 1988;62:393-398.
  • 25
    • 3242745161 scopus 로고    scopus 로고
    • Reappraisal of implant testing of implantable cardioverter defibrillators
    • Swerdlow CD: Reappraisal of implant testing of implantable cardioverter defibrillators. J Am Coll Cardiol 2004;44:92-94.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 92-94
    • Swerdlow, C.D.1
  • 27
    • 33644778037 scopus 로고    scopus 로고
    • Intraoperative testing of the implantable cardioverter-defibrillator: How much is enough?
    • Pires LA, Johnson KM: Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough? J Cardiovasc Electrophysiol 2006;17:140-145.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 140-145
    • Pires, L.A.1    Johnson, K.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.