메뉴 건너뛰기




Volumn 9, Issue 10, 2008, Pages 1059-1062

Is fixed severe pulmonary hypertension still a contraindication to heart transplant in the modern era of mechanical circulatory support? A review

Author keywords

Heart transplantation; Left ventricular assist device; Pulmonary hypertension

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DISEASE SEVERITY; EXTRACORPOREAL CIRCULATION; HEART FAILURE; HEART TRANSPLANTATION; HUMAN; ISCHEMIC HEART DISEASE; LUNG VASCULAR RESISTANCE; MALE; MEDICAL LITERATURE; PULMONARY HYPERTENSION; TREATMENT CONTRAINDICATION; COST BENEFIT ANALYSIS; DRUG CONTRAINDICATION; DRUG RESISTANCE; ECONOMICS; HEART ASSIST DEVICE; HEART VENTRICLE FUNCTION; HEMODYNAMICS; HOSPITALIZATION; MIDDLE AGED; PATHOPHYSIOLOGY; REVIEW; TREATMENT OUTCOME;

EID: 55249123869     PISSN: 15582027     EISSN: None     Source Type: Journal    
DOI: 10.2459/JCM.0b013e3282f64249     Document Type: Article
Times cited : (11)

References (19)
  • 1
    • 0030827921 scopus 로고    scopus 로고
    • Reevaluating the significance of pulmonary hypertension before cardiac transplantation: Determination of optimal thresholds and quantification of the effect of reversibility on perioperative mortality
    • Chen JM, Levin HR, Michler RE, Prusmack CJ, Rose EA, Aaronson KD. Reevaluating the significance of pulmonary hypertension before cardiac transplantation: determination of optimal thresholds and quantification of the effect of reversibility on perioperative mortality. J Thorac Cardiovasc Surg 1997; 114:627-634.
    • (1997) J Thorac Cardiovasc Surg , vol.114 , pp. 627-634
    • Chen, J.M.1    Levin, H.R.2    Michler, R.E.3    Prusmack, C.J.4    Rose, E.A.5    Aaronson, K.D.6
  • 2
    • 2442465042 scopus 로고    scopus 로고
    • Implantable left ventricular assist device for treatment of pulmonary hypertension in candidates for orthotopic heart transplantation - a preliminary study
    • Martin J, Siegenthaler MP, Friesewinkel O, Fader T, van de Loo A, Trummer G, et al. Implantable left ventricular assist device for treatment of pulmonary hypertension in candidates for orthotopic heart transplantation - a preliminary study. Eur J Cardiothorac Surg 2004; 25: 971-977.
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 971-977
    • Martin, J.1    Siegenthaler, M.P.2    Friesewinkel, O.3    Fader, T.4    van de Loo, A.5    Trummer, G.6
  • 3
    • 0026182647 scopus 로고
    • Univentricular support results in reduction of pulmonary resistance and improved right ventricular function
    • Gallagher RC, Kormos RL, Gasior T, Murali S, Griffith BP, Hardesty RL. Univentricular support results in reduction of pulmonary resistance and improved right ventricular function. ASAIO Trans 1991; 37:287-288.
    • (1991) ASAIO Trans , vol.37 , pp. 287-288
    • Gallagher, R.C.1    Kormos, R.L.2    Gasior, T.3    Murali, S.4    Griffith, B.P.5    Hardesty, R.L.6
  • 5
    • 0343376109 scopus 로고    scopus 로고
    • Left ventricular assist device support of medically unresponsive pulmonary hypertension and aortic insufficiency
    • Adamson RM, Dembitsky WP, Jaski BE, Daily PO, Moreno R, Kim JC, et al. Left ventricular assist device support of medically unresponsive pulmonary hypertension and aortic insufficiency. ASA/O J 1997; 43:365- 369.
    • (1997) ASA/O J , vol.43 , pp. 365-369
    • Adamson, R.M.1    Dembitsky, W.P.2    Jaski, B.E.3    Daily, P.O.4    Moreno, R.5    Kim, J.C.6
  • 7
    • 0037337997 scopus 로고    scopus 로고
    • Mechanical ventricular support lowers pulmonary vascular resistance in a patient with congential heart disease
    • Petrofski JA, Hoopes CW, Bashore TM, Russell SD, Milano CA. Mechanical ventricular support lowers pulmonary vascular resistance in a patient with congential heart disease. Ann Thorac Surg 2003; 75:1005-1007.
    • (2003) Ann Thorac Surg , vol.75 , pp. 1005-1007
    • Petrofski, J.A.1    Hoopes, C.W.2    Bashore, T.M.3    Russell, S.D.4    Milano, C.A.5
  • 8
    • 1542615789 scopus 로고    scopus 로고
    • Left ventricular unloading in a patient with end-stage cardiomyopathy and medically unresponsive pulmonary hypertension
    • Al-Khaldi A, Ergina P, DeVarennes B, Lachappelle K, Cecere R. Left ventricular unloading in a patient with end-stage cardiomyopathy and medically unresponsive pulmonary hypertension. Artif Organs 2004; 28:158-160.
    • (2004) Artif Organs , vol.28 , pp. 158-160
    • Al-Khaldi, A.1    Ergina, P.2    DeVarennes, B.3    Lachappelle, K.4    Cecere, R.5
  • 9
    • 13244264876 scopus 로고    scopus 로고
    • SalzbergSP, Lachat ML, von Harbou K,Zünd G, Turina MI. Normalization of high pulmonary vascular resistance with LVAD support in heart transplantation candidates. Eur J Cardio-Thorac Surg 2005; 27:222-225.
    • SalzbergSP, Lachat ML, von Harbou K,Zünd G, Turina MI. Normalization of high pulmonary vascular resistance with LVAD support in heart transplantation candidates. Eur J Cardio-Thorac Surg 2005; 27:222-225.
  • 10
    • 33846394162 scopus 로고    scopus 로고
    • Pulmonary complications after descending thoracic and thoracoabdominal aortic aneurysm repair: Predictors, prevention, and treatment
    • discussion S890-S892
    • Etz CD, Di Luozzo G, Bello R, Luehr M, Khan MZ, Bodian CA, et al. Pulmonary complications after descending thoracic and thoracoabdominal aortic aneurysm repair: predictors, prevention, and treatment. Ann Thorac Surg 2007; 83:S870-S876; [discussion S890-S892].
    • (2007) Ann Thorac Surg , vol.83
    • Etz, C.D.1    Di Luozzo, G.2    Bello, R.3    Luehr, M.4    Khan, M.Z.5    Bodian, C.A.6
  • 11
    • 33847241241 scopus 로고    scopus 로고
    • Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates
    • Zimpfer D, Zrunek P, Roethy W, Czerny M, Schima H, Huber L, et al. Left ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates. J Thorac Cardiovasc Surg 2007; 133:689- 695.
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 689-695
    • Zimpfer, D.1    Zrunek, P.2    Roethy, W.3    Czerny, M.4    Schima, H.5    Huber, L.6
  • 15
    • 1642564239 scopus 로고    scopus 로고
    • Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support
    • Klotz S, Deng MC, Stypmann J, Roetker J, Wilhelm MJ, Hammel D, et al. Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Ann Thorac Surg 2004; 77:143-149.
    • (2004) Ann Thorac Surg , vol.77 , pp. 143-149
    • Klotz, S.1    Deng, M.C.2    Stypmann, J.3    Roetker, J.4    Wilhelm, M.J.5    Hammel, D.6
  • 17
    • 0026779181 scopus 로고
    • Increased pulmonary artery elastolytic activity in adult rats with monocrotaline induced progressive hypertensive pulmonary vascular disease compared with infant rats with nonprogressive disease
    • Todorovich-Hunter L, Dodo H, Ye C, McCready L, Keeley FW, Rabinovitch M, et al. Increased pulmonary artery elastolytic activity in adult rats with monocrotaline induced progressive hypertensive pulmonary vascular disease compared with infant rats with nonprogressive disease. Am Rev Respir Dis 1992; 146:213-223.
    • (1992) Am Rev Respir Dis , vol.146 , pp. 213-223
    • Todorovich-Hunter, L.1    Dodo, H.2    Ye, C.3    McCready, L.4    Keeley, F.W.5    Rabinovitch, M.6
  • 18
    • 30044443618 scopus 로고    scopus 로고
    • Right heart failure after left ventricular assist device implantation in patients with chronic congestive heart failure
    • Dang NC, Topkara VK, Mercando M, Kay J, Kruger K, Aboodi M, et al. Right heart failure after left ventricular assist device implantation in patients with chronic congestive heart failure. J Heart Lung Transplant 2006; 25: 1-6.
    • (2006) J Heart Lung Transplant , vol.25 , pp. 1-6
    • Dang, N.C.1    Topkara, V.K.2    Mercando, M.3    Kay, J.4    Kruger, K.5    Aboodi, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.