메뉴 건너뛰기




Volumn 10, Issue 9, 2008, Pages 1042-1047

Magnetically guided left ventricular lead implantation based on a virtual three-dimensional reconstructed image of the coronary sinus

Author keywords

Cardiac resynchronization therapy; Implantation; Left ventricular lead; Magnetic navigation; Three dimensional reconstruction

Indexed keywords

ANGIOCARDIOGRAPHY; ARTICLE; CANNULATION; CARDIAC RESYNCHRONIZATION THERAPY; CLINICAL ARTICLE; CLINICAL EVALUATION; COMPARATIVE STUDY; CONTROLLED STUDY; CORONARY SINUS; DIAGNOSTIC ACCURACY; FEASIBILITY STUDY; FLUOROSCOPY; GUIDE WIRE; HEART FAILURE; HEART LEFT VENTRICLE EJECTION FRACTION; HUMAN; LEFT VENTRICULAR LEAD IMPLANTATION; MAGNETIC FIELD; METAL IMPLANTATION; PRIORITY JOURNAL; SYSTOLIC HEART MURMUR; THREE DIMENSIONAL IMAGING; WIRE FIXATION; ARTIFICIAL HEART PACEMAKER; CLINICAL TRIAL; ELECTRODE; FEMALE; HEART VENTRICLE; IMPLANTATION; INSTRUMENTATION; MAGNETISM; MALE; METHODOLOGY; PATHOLOGY; TREATMENT OUTCOME;

EID: 55249113997     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eun173     Document Type: Article
Times cited : (13)

References (12)
  • 1
    • 33644758635 scopus 로고    scopus 로고
    • Left ventricular lead placement within a coronary sinus side branch using remote magnetic navigation of a guidewire: A feasibility study
    • Rivero-Ayerza M, Thornton AS, Theuns DA, Marcoen F, Scholten, Joris Mekel et al. Left ventricular lead placement within a coronary sinus side branch using remote magnetic navigation of a guidewire: a feasibility study. J Cardiovasc Electrophysiol 2006;17:128-33.
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 128-133
    • Rivero-Ayerza, M.1    Thornton, A.S.2    Theuns, D.A.3    Marcoen, F.4    Scholten, J.M.5
  • 2
    • 33846391950 scopus 로고    scopus 로고
    • Initial clinical experience with cardiac resynchronization therapy utilizing a magnetic navigation system
    • Gallagher P, Martin L, Angel L, Tomassoni G. Initial clinical experience with cardiac resynchronization therapy utilizing a magnetic navigation system. J Cardiovasc Electrophysiol 2007;18:174-80.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 174-180
    • Gallagher, P.1    Martin, L.2    Angel, L.3    Tomassoni, G.4
  • 3
    • 38549147530 scopus 로고    scopus 로고
    • First direct in vivo comparison of two commercially available three-dimensional quantitative coronary angiography systems
    • Ramcharitar S, Daeman J, Patterson M, van Guens RJ, Boersma E, Serruys PW et al. First direct in vivo comparison of two commercially available three-dimensional quantitative coronary angiography systems. Catheter Cardiovasc Interv 2008;71:44-50.
    • (2008) Catheter Cardiovasc Interv , vol.71 , pp. 44-50
    • Ramcharitar, S.1    Daeman, J.2    Patterson, M.3    van Guens, R.J.4    Boersma, E.5    Serruys, P.W.6
  • 4
    • 0037392830 scopus 로고    scopus 로고
    • Robotically assisted left ventricular epicardial lead implantation for biventricular pacing
    • DeRose JJ, Ashton RC, Belsley S, Shaw R, Ashton RC Jr. Robotically assisted left ventricular epicardial lead implantation for biventricular pacing. J Am Coll Cardiol 2003;41:1414-9.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 1414-1419
    • DeRose, J.J.1    Ashton, R.C.2    Belsley, S.3    Shaw, R.4    Ashton Jr., R.C.5
  • 6
    • 33846860020 scopus 로고    scopus 로고
    • Left ventricular lead implantation assisted by magnetic navigation in a patient with a persistent left superior vena cava
    • Rivero-Ayerza M, van Belle Y, Mekel J, Jordaens L. Left ventricular lead implantation assisted by magnetic navigation in a patient with a persistent left superior vena cava. Int J Cardiol 2007;2;116:e15-7.
    • (2007) Int J Cardiol , vol.2 , Issue.116
    • Rivero-Ayerza, M.1    van Belle, Y.2    Mekel, J.3    Jordaens, L.4
  • 7
    • 34249868485 scopus 로고    scopus 로고
    • Magnetic navigation system used successfully to cross a crushed stent in a bifurcation that failed with conventional wires
    • Ramcharitar S, Patterson MS, van Guens RJ, Serruys PW. Magnetic navigation system used successfully to cross a crushed stent in a bifurcation that failed with conventional wires. Catheter Cardiovasc Interv 2007; 69:852-5.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 852-855
    • Ramcharitar, S.1    Patterson, M.S.2    van Guens, R.J.3    Serruys, P.W.4
  • 9
    • 33745197531 scopus 로고    scopus 로고
    • Magnetic navigation in AV nodal re-entrant tachycardia study: Early results of ablation with one- and three-magnet catheters
    • Thornton AS, Janse P, Theuns DA, Scholten MF, Jordaens LJ. Magnetic navigation in AV nodal re-entrant tachycardia study: early results of ablation with one- and three-magnet catheters. Europace 2006;8: 225-30.
    • (2006) Europace , vol.8 , pp. 225-230
    • Thornton, A.S.1    Janse, P.2    Theuns, D.A.3    Scholten, M.F.4    Jordaens, L.J.5
  • 10
    • 34247502871 scopus 로고    scopus 로고
    • Magnetic navigation in left-sided AV reentrant tachycardias: Preliminary results of a retrograde approach
    • Thornton AS, Rivero-Ayerza M, Knops P, Jordaens LJ. Magnetic navigation in left-sided AV reentrant tachycardias: preliminary results of a retrograde approach. J Cardiovasc Electrophysiol 2007;18:467-72.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 467-472
    • Thornton, A.S.1    Rivero-Ayerza, M.2    Knops, P.3    Jordaens, L.J.4
  • 11
    • 12144289547 scopus 로고    scopus 로고
    • Initial experience with remote catheter ablation using a novel magnetic navigation system: Magnetic remote catheter ablation
    • Ernst S, Ouyang F, Linder C, Hertting K, Stahl F, Chun J et al. Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation. Circulation 2004;109: 1472-5.
    • (2004) Circulation , vol.109 , pp. 1472-1475
    • Ernst, S.1    Ouyang, F.2    Linder, C.3    Hertting, K.4    Stahl, F.5    Chun, J.6
  • 12
    • 1842542892 scopus 로고    scopus 로고
    • Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system Niobe
    • Ernst S, Ouyang F, Linder C, Hertting K, Stahl F, Chun J et al. Modulation of the slow pathway in the presence of a persistent left superior caval vein using the novel magnetic navigation system Niobe. Europace 2004;6:10-4.
    • (2004) Europace , vol.6 , pp. 10-14
    • Ernst, S.1    Ouyang, F.2    Linder, C.3    Hertting, K.4    Stahl, F.5    Chun, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.