메뉴 건너뛰기




Volumn 43, Issue 9, 2008, Pages 663-668

Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0 t: Comparison with steady-state free precession technique at 1.5 T

Author keywords

3.0 T; Coronary arteries; Magnetic resonance angiography

Indexed keywords

BETA ADRENERGIC RECEPTOR BLOCKING AGENT; GADOBENATE DIMEGLUMINE; GLYCERYL TRINITRATE; CONTRAST MEDIUM; DIAGNOSTIC AGENT; DRUG DERIVATIVE; GADOBENIC ACID; MEGLUMINE; ORGANOMETALLIC COMPOUND;

EID: 55249113497     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e31817ed1ff     Document Type: Article
Times cited : (75)

References (16)
  • 1
    • 33750372663 scopus 로고    scopus 로고
    • Cardiac MR imaging: State of the technology
    • Finn JP, Nael K, Deshpande V, et al. Cardiac MR imaging: state of the technology. Radiology. 2006;241:338-354.
    • (2006) Radiology , vol.241 , pp. 338-354
    • Finn, J.P.1    Nael, K.2    Deshpande, V.3
  • 2
    • 0036708122 scopus 로고    scopus 로고
    • Preliminary report on in vivo coronary MRA at 3 Tesla in humans
    • Stuber M, Botnar RM, Fischer SE, et al. Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med. 2002;48:425-429.
    • (2002) Magn Reson Med , vol.48 , pp. 425-429
    • Stuber, M.1    Botnar, R.M.2    Fischer, S.E.3
  • 3
    • 33645788294 scopus 로고    scopus 로고
    • Bj-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T
    • Nezafat R, Stuber M, Ouwerkerk R, et al. Bj-insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T. Magn Reson Med. 2006;55:858-864.
    • (2006) Magn Reson Med , vol.55 , pp. 858-864
    • Nezafat, R.1    Stuber, M.2    Ouwerkerk, R.3
  • 4
    • 8444225836 scopus 로고    scopus 로고
    • Evaluation of balanced steady-state free precession (TrueFISP) and k-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla
    • Kaul MG, Stork A, Bansmann PM, et al. Evaluation of balanced steady-state free precession (TrueFISP) and k-space segmented gradient echo sequences for 3D coronary MR angiography with navigator gating at 3 Tesla. Rofo. 2004;176:1560-1565.
    • (2004) Rofo , vol.176 , pp. 1560-1565
    • Kaul, M.G.1    Stork, A.2    Bansmann, P.M.3
  • 5
    • 1642528008 scopus 로고    scopus 로고
    • Coronary MR angiography: Comparison of quantitative and qualitative data from four techniques
    • Maintz D, Aepfelbacher FC, Kissinger KV, et al. Coronary MR angiography: comparison of quantitative and qualitative data from four techniques. AJR Am J Roentgenol. 2004;182:515-521.
    • (2004) AJR Am J Roentgenol , vol.182 , pp. 515-521
    • Maintz, D.1    Aepfelbacher, F.C.2    Kissinger, K.V.3
  • 6
    • 12744268351 scopus 로고    scopus 로고
    • Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography
    • Bi X, Li D. Coronary arteries at 3.0 T: contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography. J Magn Reson Imaging. 2005;21:133-139.
    • (2005) J Magn Reson Imaging , vol.21 , pp. 133-139
    • Bi, X.1    Li, D.2
  • 7
    • 34547756536 scopus 로고    scopus 로고
    • Bi X, Carr J, Li D. Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high relaxivity clinical contrast agent. Magn Reson Med. 2007;58:l-7.
    • Bi X, Carr J, Li D. Whole-heart coronary magnetic resonance angiography at 3 Tesla in 5 minutes with slow infusion of Gd-BOPTA, a high relaxivity clinical contrast agent. Magn Reson Med. 2007;58:l-7.
  • 8
    • 4344560587 scopus 로고    scopus 로고
    • Parallel acquisition techniques in cardiac cine magnetic resonance imaging using TrueFISP sequences: Comparison of image quality and artifacts
    • Hunold P, Maderwald S, Ladd ME, et al. Parallel acquisition techniques in cardiac cine magnetic resonance imaging using TrueFISP sequences: comparison of image quality and artifacts. J Magn Reson Imaging. 2004;20:506-511.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 506-511
    • Hunold, P.1    Maderwald, S.2    Ladd, M.E.3
  • 9
    • 0016490238 scopus 로고
    • A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Associate
    • Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Associate. Circulation. 1975;51:5-40.
    • (1975) Circulation , vol.51 , pp. 5-40
    • Austen, W.G.1    Edwards, J.E.2    Frye, R.L.3
  • 10
    • 33744549479 scopus 로고    scopus 로고
    • Toward single breath-hold whole-heart coverage coronary MR angiography using highly accelerated parallel imaging with a 32-channel MR system
    • Niendorf T, Hardy CJ, Giaquinto RO, et al. Toward single breath-hold whole-heart coverage coronary MR angiography using highly accelerated parallel imaging with a 32-channel MR system. Magn Reson Med. 2006;56:167-176.
    • (2006) Magn Reson Med , vol.56 , pp. 167-176
    • Niendorf, T.1    Hardy, C.J.2    Giaquinto, R.O.3
  • 11
    • 11144319493 scopus 로고    scopus 로고
    • Spiral magnetic resonance coronary angiography - direct comparison of 1. 5 Tesla vs. 3 Tesla
    • Yang PC, Nguyen P, Shimakawa A, et al. Spiral magnetic resonance coronary angiography - direct comparison of 1. 5 Tesla vs. 3 Tesla. J Cardiovasc Magn Reson. 2004;6:877-884.
    • (2004) J Cardiovasc Magn Reson , vol.6 , pp. 877-884
    • Yang, P.C.1    Nguyen, P.2    Shimakawa, A.3
  • 12
    • 13844296980 scopus 로고    scopus 로고
    • Coronary MR angiography at 3.0 T versus that at 1.5 T: Initial results in patients suspected of having coronary artery disease
    • Sommer T, Hackenbroch M, Hofer U, et al. Coronary MR angiography at 3.0 T versus that at 1.5 T: initial results in patients suspected of having coronary artery disease. Radiology. 2005;234:718-725.
    • (2005) Radiology , vol.234 , pp. 718-725
    • Sommer, T.1    Hackenbroch, M.2    Hofer, U.3
  • 13
    • 22944464808 scopus 로고    scopus 로고
    • Three-dimensional breathhold SSFP coronary MRA: A comparison between 1.5 T and 3.0 T
    • Bi X, Deshpande V, Simonetti O, et al. Three-dimensional breathhold SSFP coronary MRA: a comparison between 1.5 T and 3.0 T. J Magn Reson Imaging. 2005;22:206-212.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 206-212
    • Bi, X.1    Deshpande, V.2    Simonetti, O.3
  • 14
    • 34447323307 scopus 로고    scopus 로고
    • Whole-heart coronary magnetic resonance angiography: Contrast-enhanced high-resolution, time-resolved 3D imaging
    • Warmuth C, Schnorr J, Kaufels N, et al. Whole-heart coronary magnetic resonance angiography: contrast-enhanced high-resolution, time-resolved 3D imaging. Invest Radiol. 2007;42:550-557.
    • (2007) Invest Radiol , vol.42 , pp. 550-557
    • Warmuth, C.1    Schnorr, J.2    Kaufels, N.3
  • 15
    • 33745904454 scopus 로고    scopus 로고
    • Detection of coronary stenoses with contrast enhanced, three-dimensional free breathing coronary MR angiography using the gadolinium-based intravascular contrast agent gadocoletic acid (B-22956)
    • Paetsch I, Jahnke C, Barkhausen J, et al. Detection of coronary stenoses with contrast enhanced, three-dimensional free breathing coronary MR angiography using the gadolinium-based intravascular contrast agent gadocoletic acid (B-22956). J Cardiovasc Magn Reson. 2006;8:509-516.
    • (2006) J Cardiovasc Magn Reson , vol.8 , pp. 509-516
    • Paetsch, I.1    Jahnke, C.2    Barkhausen, J.3
  • 16
    • 27644527486 scopus 로고    scopus 로고
    • Image reconstruction in SNR units: A general method for SNR measurement
    • Kellman P, McVeigh ER. Image reconstruction in SNR units: a general method for SNR measurement. Magn Reson Med. 2005;54:1439-1447.
    • (2005) Magn Reson Med , vol.54 , pp. 1439-1447
    • Kellman, P.1    McVeigh, E.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.