Direct and Indirect Measurement of Patient Radiation Exposure during Endovascular Aortic Aneurysm Repair

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA ANEURYSM; ADULT; AGED; ARTICLE; BODY MASS; CLINICAL ARTICLE; DOSIMETRY; ENDOVASCULAR SURGERY; FEMALE; FLUOROSCOPY; HUMAN; MALE; OBESITY; PATIENT SAFETY; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; RADIATION MEASUREMENT; SKIN; SKIN INJURY; TREATMENT DURATION;

EID: 55049129290     PISSN: 08905096     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.avsg.2008.06.008     Document Type: Article
Times cited : (43)

References (23)
  • 1
    • 0036221564 scopus 로고    scopus 로고
    • Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures
    • Fletcher D.W., Miller D.L., Balter S., et al. Comparison of four techniques to estimate radiation dose to skin during angiographic and interventional radiology procedures. J. Vasc. Interv. Radiol 13 (2002) 391-397
    • (2002) J. Vasc. Interv. Radiol , vol.13 , pp. 391-397
    • Fletcher, D.W.1    Miller, D.L.2    Balter, S.3
  • 2
    • 13444270562 scopus 로고    scopus 로고
    • ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures: a report of the American College of Cardiology Foundation/American Heart Association/American College of Physician Task Force on Clinical Competence Training
    • Hirshfield J.W., Balter S., Brinker J.A., et al. ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures: a report of the American College of Cardiology Foundation/American Heart Association/American College of Physician Task Force on Clinical Competence Training. Circulation 111 (2005) 511-532
    • (2005) Circulation , vol.111 , pp. 511-532
    • Hirshfield, J.W.1    Balter, S.2    Brinker, J.A.3
  • 3
    • 0034979308 scopus 로고    scopus 로고
    • Skin injury from fluoroscopically guided procedures: part 2. Review of 73 cases and recommendations for minimizing dose delivered to patient
    • Koenig T.R., Mettler F.A., and Wagner L.K. Skin injury from fluoroscopically guided procedures: part 2. Review of 73 cases and recommendations for minimizing dose delivered to patient. A.J.R. Am. J. Roentgenol 177 (2001) 13-20
    • (2001) A.J.R. Am. J. Roentgenol , vol.177 , pp. 13-20
    • Koenig, T.R.1    Mettler, F.A.2    Wagner, L.K.3
  • 4
    • 2342505219 scopus 로고    scopus 로고
    • Quality improvement guidelines for recording patient radiation dose in the medical record
    • Miller D.L., Balter S., and Wagner L.K. Quality improvement guidelines for recording patient radiation dose in the medical record. J. Vasc. Interv. Radiol 15 (2004) 423-429
    • (2004) J. Vasc. Interv. Radiol , vol.15 , pp. 423-429
    • Miller, D.L.1    Balter, S.2    Wagner, L.K.3
  • 5
    • 0032426068 scopus 로고    scopus 로고
    • Entrance skin dose estimates derived from dose-area-product measurements in interventional radiologic procedures
    • McParland B.J. Entrance skin dose estimates derived from dose-area-product measurements in interventional radiologic procedures. Br. J. Radiol 71 (1998) 1288-1295
    • (1998) Br. J. Radiol , vol.71 , pp. 1288-1295
    • McParland, B.J.1
  • 6
    • 0038294287 scopus 로고    scopus 로고
    • Radiation dose in interventional radiology procedures: the RAD-IR study. Part II: Skin dose
    • Miller D.L., Balter S., Cole P.E., et al. Radiation dose in interventional radiology procedures: the RAD-IR study. Part II: Skin dose. J. Vasc. Interv. Radiol 14 (2003) 977-990
    • (2003) J. Vasc. Interv. Radiol , vol.14 , pp. 977-990
    • Miller, D.L.1    Balter, S.2    Cole, P.E.3
  • 7
    • 0033786756 scopus 로고    scopus 로고
    • Does the endovascular repair of aortoiliac aneurysms pose a radiation safety hazard to vascular surgeons?
    • Lipsitz E.C., Veith F.J., Ohki T., et al. Does the endovascular repair of aortoiliac aneurysms pose a radiation safety hazard to vascular surgeons?. J. Vasc. Surg 32 (2000) 704-710
    • (2000) J. Vasc. Surg , vol.32 , pp. 704-710
    • Lipsitz, E.C.1    Veith, F.J.2    Ohki, T.3
  • 8
    • 33746626962 scopus 로고    scopus 로고
    • Methods of measuring fluoroscopic skin dose
    • Balter S. Methods of measuring fluoroscopic skin dose. Pediatr. Radiol 36 (2006) 136-140
    • (2006) Pediatr. Radiol , vol.36 , pp. 136-140
    • Balter, S.1
  • 9
    • 0036828515 scopus 로고    scopus 로고
    • Minimizing radiation-induced skin injury in interventional radiology procedures
    • Miller D.L., Balter S., Noonan P.T., et al. Minimizing radiation-induced skin injury in interventional radiology procedures. Radiology 225 2 (2002) 329-336
    • (2002) Radiology , vol.225 , Issue.2 , pp. 329-336
    • Miller, D.L.1    Balter, S.2    Noonan, P.T.3
  • 10
    • 0034989324 scopus 로고    scopus 로고
    • Skin injuries from fluoroscopically guided procedures: part 1. Characteristics of radiation injury
    • Koenig T.R., Wolff D., Mettler F.A., et al. Skin injuries from fluoroscopically guided procedures: part 1. Characteristics of radiation injury. A.J.R. Am. J. Roentgenol 177 (2001) 3-11
    • (2001) A.J.R. Am. J. Roentgenol , vol.177 , pp. 3-11
    • Koenig, T.R.1    Wolff, D.2    Mettler, F.A.3
  • 12
    • 0033956957 scopus 로고    scopus 로고
    • Management of patient skin dose in fluoroscopic guided interventional procedures
    • Wagner L.K., Archer B.R., and Cohen A.M. Management of patient skin dose in fluoroscopic guided interventional procedures. J. Vasc. Interv. Radiol 11 (2000) 25-33
    • (2000) J. Vasc. Interv. Radiol , vol.11 , pp. 25-33
    • Wagner, L.K.1    Archer, B.R.2    Cohen, A.M.3
  • 13
    • 33744772191 scopus 로고    scopus 로고
    • Endovascular and interventional procedures in obese patients: a review of procedural technique modifications and radiation management
    • Bryk S.G., Censullo M.L., Wagner L.K., et al. Endovascular and interventional procedures in obese patients: a review of procedural technique modifications and radiation management. J. Vasc. Interv. Radiol 17 (2006) 27-33
    • (2006) J. Vasc. Interv. Radiol , vol.17 , pp. 27-33
    • Bryk, S.G.1    Censullo, M.L.2    Wagner, L.K.3
  • 14
    • 6444233261 scopus 로고    scopus 로고
    • Fluoroscopy: recording of fluoroscopic images and automatic exposure control
    • Geise R.A. Fluoroscopy: recording of fluoroscopic images and automatic exposure control. Radiographics 21 (2001) 227-236
    • (2001) Radiographics , vol.21 , pp. 227-236
    • Geise, R.A.1
  • 15
    • 55049101780 scopus 로고    scopus 로고
    • World Health Organization. InfoBase Online WHO Global Comparable Estimates for BMI (2005), http://www.who.int/ncd_surveillance/infobase/web/InfoBasePolicyMaker/CountryProfiles/QCStart.aspx (accessed May 29, 2007).
    • World Health Organization. InfoBase Online WHO Global Comparable Estimates for BMI (2005), http://www.who.int/ncd_surveillance/infobase/web/InfoBasePolicyMaker/CountryProfiles/QCStart.aspx (accessed May 29, 2007).
  • 16
    • 34447099033 scopus 로고    scopus 로고
    • Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation
    • Ector J., Dragusin O., Adriaenssens B., et al. Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation. J. Am. Coll. Cardiol 50 (2007) 234-242
    • (2007) J. Am. Coll. Cardiol , vol.50 , pp. 234-242
    • Ector, J.1    Dragusin, O.2    Adriaenssens, B.3
  • 17
    • 34548429967 scopus 로고    scopus 로고
    • Ionizing radiation absorption of vascular surgeons during endovascular procedures
    • Ho P., Cheng S., Wu P.M., et al. Ionizing radiation absorption of vascular surgeons during endovascular procedures. J. Vasc. Surg 46 (2007) 455-459
    • (2007) J. Vasc. Surg , vol.46 , pp. 455-459
    • Ho, P.1    Cheng, S.2    Wu, P.M.3
  • 18
    • 0033975295 scopus 로고    scopus 로고
    • Skin sparing in interventional radiology: the effect of copper filtration
    • Nicholson R., Tuffee F., and Uthappa M.C. Skin sparing in interventional radiology: the effect of copper filtration. Br. J. Radiol 73 (2000) 36-42
    • (2000) Br. J. Radiol , vol.73 , pp. 36-42
    • Nicholson, R.1    Tuffee, F.2    Uthappa, M.C.3
  • 20
    • 10744219719 scopus 로고    scopus 로고
    • Cancer risks attributable to low doses of ionizing radiation: assessing what we really know
    • Brenner D.J., Doll R., Goodhead D.T., et al. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc. Natl. Acad. Sci. USA 100 (2003) 13761-13766
    • (2003) Proc. Natl. Acad. Sci. USA , vol.100 , pp. 13761-13766
    • Brenner, D.J.1    Doll, R.2    Goodhead, D.T.3
  • 21
    • 85032843101 scopus 로고    scopus 로고
    • Board on Radiation Effects Research, Division on Earth and Life Studies. Executive Summary, National Academy Press, Washington DC
    • Board on Radiation Effects Research, Division on Earth and Life Studies. Executive Summary. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII-phase 2 (2005), National Academy Press, Washington DC
    • (2005) Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII-phase 2
  • 22
    • 34247881892 scopus 로고    scopus 로고
    • Imaging strategies to reduce the risk of radiation in CT studies, including selective substitution with MRI
    • Semelka R.C., Armao D.M., Elias J., and Huda W. Imaging strategies to reduce the risk of radiation in CT studies, including selective substitution with MRI. J. Magn. Reson. Imaging 25 (2007) 900-909
    • (2007) J. Magn. Reson. Imaging , vol.25 , pp. 900-909
    • Semelka, R.C.1    Armao, D.M.2    Elias, J.3    Huda, W.4
  • 23
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-an increasing source of radiation exposure
    • Brenner D.J., and Hall E.J. Computed tomography-an increasing source of radiation exposure. N. Engl. J. Med 357 (2007) 2277-2284
    • (2007) N. Engl. J. Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.