메뉴 건너뛰기




Volumn 17, Issue 6, 2008, Pages 845-852

Repair integrity and clinical outcome after arthroscopic rotator cuff repair using single-row anchor fixation: A prospective study of single-tendon and two-tendon tears

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTHROSCOPIC ROTATOR CUFF REPAIR; ARTHROSCOPIC SURGERY; ARTICLE; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CLINICAL TRIAL; FEMALE; FOLLOW UP; FUNCTIONAL ASSESSMENT; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; ORTHOPEDIC SURGERY; OUTCOME ASSESSMENT; PAIN; PATIENT SATISFACTION; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RECURRENT DISEASE; ROTATOR CUFF INJURY; ROTATOR CUFF RUPTURE; SHOULDER ARTHROSCOPY; SHOULDER INJURY; SINGLE ROW ANCHOR FIXATION; SURGEON; TENODESIS; TREATMENT INDICATION; TREATMENT OUTCOME;

EID: 55049123970     PISSN: 10582746     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jse.2008.04.004     Document Type: Article
Times cited : (31)

References (31)
  • 1
    • 33750732922 scopus 로고    scopus 로고
    • Outcome and structural integrity after arthroscopic rotator cuff repair using 2 rows of fixation: minimum 2-year follow-up
    • Anderson K., Boothby M., Aschenbrener D., and van Holsbeeck M. Outcome and structural integrity after arthroscopic rotator cuff repair using 2 rows of fixation: minimum 2-year follow-up. Am J Sports Med 34 (2006) 1899-1905
    • (2006) Am J Sports Med , vol.34 , pp. 1899-1905
    • Anderson, K.1    Boothby, M.2    Aschenbrener, D.3    van Holsbeeck, M.4
  • 2
    • 33646203224 scopus 로고    scopus 로고
    • Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study
    • Bishop J., Klepps S., Lo I.K., Bird J., Gladstone J., and Flatow E.L. Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study. J Shoulder Elbow Surg 15 (2006) 290-299
    • (2006) J Shoulder Elbow Surg , vol.15 , pp. 290-299
    • Bishop, J.1    Klepps, S.2    Lo, I.K.3    Bird, J.4    Gladstone, J.5    Flatow, E.L.6
  • 4
    • 0026352109 scopus 로고
    • Arthroscopic treatment of massive rotator cuff tears. Clinical results and biomechanical rationale
    • Burkhart S.S. Arthroscopic treatment of massive rotator cuff tears. Clinical results and biomechanical rationale. Clin Orthop 267 (1991) 45-56
    • (1991) Clin Orthop , vol.267 , pp. 45-56
    • Burkhart, S.S.1
  • 5
    • 34447529361 scopus 로고    scopus 로고
    • Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair?: A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment
    • Charousset C., Grimberg J., Duranthon L., Bellaiche L., and Petrover D. Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair?: A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment. Am J Sports Med 35 (2007) 1247-1253
    • (2007) Am J Sports Med , vol.35 , pp. 1247-1253
    • Charousset, C.1    Grimberg, J.2    Duranthon, L.3    Bellaiche, L.4    Petrover, D.5
  • 6
    • 34548699369 scopus 로고    scopus 로고
    • Arthroscopic rotator cuff repair: prospective functional outcome and repair integrity at minimum 2-year follow up
    • Cole B., McCarty III L.P., Kang R., Alford W., Lewis P.B., and Hayden J. Arthroscopic rotator cuff repair: prospective functional outcome and repair integrity at minimum 2-year follow up. J Shoulder Elbow Surg 16 (2007) 579-585
    • (2007) J Shoulder Elbow Surg , vol.16 , pp. 579-585
    • Cole, B.1    McCarty III, L.P.2    Kang, R.3    Alford, W.4    Lewis, P.B.5    Hayden, J.6
  • 7
    • 55049133131 scopus 로고    scopus 로고
    • Deutsch A. Arthroscopic rotator cuff repair: The effect of depth of suture passage on three-dimensional repair site surface area and load to failure using single-row anchor fixation. Presented at: The Seventy-Third Annual Meeting of the American Academy of Orthopaedic Surgeons, Chicago, IL; March 2006.
    • Deutsch A. Arthroscopic rotator cuff repair: The effect of depth of suture passage on three-dimensional repair site surface area and load to failure using single-row anchor fixation. Presented at: The Seventy-Third Annual Meeting of the American Academy of Orthopaedic Surgeons, Chicago, IL; March 2006.
  • 9
    • 34447560059 scopus 로고    scopus 로고
    • Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: a randomized controlled trial
    • Franceschi F., Ruzzini L., Giuseppe L., et al. Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: a randomized controlled trial. Am J Sports Med 35 (2007) 1254-1260
    • (2007) Am J Sports Med , vol.35 , pp. 1254-1260
    • Franceschi, F.1    Ruzzini, L.2    Giuseppe, L.3
  • 10
    • 0942279683 scopus 로고    scopus 로고
    • The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears
    • Galatz L.M., Ball C.M., Teefey S.A., Middleton W.D., and Yamaguchi K. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg Am 86 (2004) 219-224
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 219-224
    • Galatz, L.M.1    Ball, C.M.2    Teefey, S.A.3    Middleton, W.D.4    Yamaguchi, K.5
  • 11
    • 0031808081 scopus 로고    scopus 로고
    • Arthroscopic repair of full-thickness tears of the rotator cuff
    • Gartsman G.M., Khan M., and Hammerman S.M. Arthroscopic repair of full-thickness tears of the rotator cuff. J Bone Joint Surg Am 80 (1998) 832-840
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 832-840
    • Gartsman, G.M.1    Khan, M.2    Hammerman, S.M.3
  • 14
    • 0032111038 scopus 로고    scopus 로고
    • Passive tension in the supraspinatus musculotendinous unit after long-standing rupture of its tendon: a preliminary report
    • Hersche O., and Gerber C. Passive tension in the supraspinatus musculotendinous unit after long-standing rupture of its tendon: a preliminary report. J Shoulder Elbow Surg 7 (1998) 393-396
    • (1998) J Shoulder Elbow Surg , vol.7 , pp. 393-396
    • Hersche, O.1    Gerber, C.2
  • 16
    • 0034016174 scopus 로고    scopus 로고
    • Clinical outcome after structural failure of rotator cuff repairs
    • Jost B., Pfirrmann C.W., and Gerber C. Clinical outcome after structural failure of rotator cuff repairs. J Bone Joint Surg Am 82 (2000) 304-314
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 304-314
    • Jost, B.1    Pfirrmann, C.W.2    Gerber, C.3
  • 17
    • 32944480447 scopus 로고    scopus 로고
    • Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair
    • Kim D.H., Elattrache N.S., Tibone J.E., et al. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am J Sports Med 34 (2006) 401-414
    • (2006) Am J Sports Med , vol.34 , pp. 401-414
    • Kim, D.H.1    Elattrache, N.S.2    Tibone, J.E.3
  • 18
    • 6344253406 scopus 로고    scopus 로고
    • Prospective evaluation of the effect of rotator cuff integrity on the outcome of open rotator cuff repairs
    • Klepps S., Bishop J., Lin J., et al. Prospective evaluation of the effect of rotator cuff integrity on the outcome of open rotator cuff repairs. Am J Sports Med 32 (2004) 1716-1722
    • (2004) Am J Sports Med , vol.32 , pp. 1716-1722
    • Klepps, S.1    Bishop, J.2    Lin, J.3
  • 19
    • 34447272895 scopus 로고    scopus 로고
    • The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique
    • Lafosse L., Brozska R., Toussaint B., and Gobezie R. The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am 89 (2007) 1533-1541
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 1533-1541
    • Lafosse, L.1    Brozska, R.2    Toussaint, B.3    Gobezie, R.4
  • 20
    • 34547748291 scopus 로고    scopus 로고
    • Magnetic resonance imaging of arthroscopic supraspinatus tendon repair
    • Liem D., Lichtenberg S., Magosch P., and Habermeyer P. Magnetic resonance imaging of arthroscopic supraspinatus tendon repair. J Bone Joint Surg Am 89 (2007) 1770-1776
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 1770-1776
    • Liem, D.1    Lichtenberg, S.2    Magosch, P.3    Habermeyer, P.4
  • 21
    • 31844453610 scopus 로고    scopus 로고
    • Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation
    • Ma C.B., Comerford L., Wilson J., and Puttlitz C.M. Biomechanical evaluation of arthroscopic rotator cuff repairs: double-row compared with single-row fixation. J Bone Joint Surg Am 88 (2006) 403-410
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 403-410
    • Ma, C.B.1    Comerford, L.2    Wilson, J.3    Puttlitz, C.M.4
  • 22
    • 0031980943 scopus 로고    scopus 로고
    • Humeral attachments of the supraspinatus and infraspinatus tendons: an anatomic study
    • Minagawa H., Itoi E., Norikazu K., et al. Humeral attachments of the supraspinatus and infraspinatus tendons: an anatomic study. Arthroscopy 14 (1998) 302-306
    • (1998) Arthroscopy , vol.14 , pp. 302-306
    • Minagawa, H.1    Itoi, E.2    Norikazu, K.3
  • 23
    • 0037492887 scopus 로고    scopus 로고
    • The effect of infraspinatus disruption on glenohumeral torque and superior migration of the humeral head: a biomechanical study
    • Mura N., O'Driscoll S.W., Zobitz M.E., et al. The effect of infraspinatus disruption on glenohumeral torque and superior migration of the humeral head: a biomechanical study. J Shoulder Elbow Surg 12 (2003) 179-184
    • (2003) J Shoulder Elbow Surg , vol.12 , pp. 179-184
    • Mura, N.1    O'Driscoll, S.W.2    Zobitz, M.E.3
  • 24
    • 0036357088 scopus 로고    scopus 로고
    • Arthroscopic repair of medium to large full-thickness rotator cuff tears: outcome at 2- to 6-year follow-up
    • Murray T.F., Lajtai G., Mileski R.M., and Synder S.J. Arthroscopic repair of medium to large full-thickness rotator cuff tears: outcome at 2- to 6-year follow-up. J Shoulder Elbow Surg 11 (2002) 19-24
    • (2002) J Shoulder Elbow Surg , vol.11 , pp. 19-24
    • Murray, T.F.1    Lajtai, G.2    Mileski, R.M.3    Synder, S.J.4
  • 25
    • 0025239585 scopus 로고
    • Classification of rotator cuff lesions
    • Patte D. Classification of rotator cuff lesions. Clin Orthop 254 (1990) 81-86
    • (1990) Clin Orthop , vol.254 , pp. 81-86
    • Patte, D.1
  • 27
    • 28444453275 scopus 로고    scopus 로고
    • Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation
    • Sugaya H., Maeda K., Matsuki K., and Moriishi J. Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation. Arthroscopy 21 (2005) 1307-1316
    • (2005) Arthroscopy , vol.21 , pp. 1307-1316
    • Sugaya, H.1    Maeda, K.2    Matsuki, K.3    Moriishi, J.4
  • 28
    • 55049114553 scopus 로고    scopus 로고
    • Sugaya H, Maeda K, Matsuki K, Moriishi J. Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair: a prospective outcome study. Presented at: The Twenty-Second Open Meeting of the American Shoulder and Elbow Surgeons, Chicago, IL, March 25, 2006.
    • Sugaya H, Maeda K, Matsuki K, Moriishi J. Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair: a prospective outcome study. Presented at: The Twenty-Second Open Meeting of the American Shoulder and Elbow Surgeons, Chicago, IL, March 25, 2006.
  • 29
    • 0030716507 scopus 로고    scopus 로고
    • Prediction of rotator cuff repair results by magnetic resonance imaging
    • Thomazeau H., Boukobza E., Morcet N., Chaperon J., and Langlais F. Prediction of rotator cuff repair results by magnetic resonance imaging. Clin Orthop 344 (1997) 275-283
    • (1997) Clin Orthop , vol.344 , pp. 275-283
    • Thomazeau, H.1    Boukobza, E.2    Morcet, N.3    Chaperon, J.4    Langlais, F.5
  • 31
    • 28344449190 scopus 로고    scopus 로고
    • Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair
    • Tuoheti Y., Itoi E., Yamamoto N., et al. Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair. Am J Sports Med 33 (2005) 1869-1874
    • (2005) Am J Sports Med , vol.33 , pp. 1869-1874
    • Tuoheti, Y.1    Itoi, E.2    Yamamoto, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.