메뉴 건너뛰기




Volumn 36, Issue 6, 2008, Pages 611-622

Accurate calibration of mercury vapour indicators for occupational exposure measurements using a dynamic mercury vapour generator

Author keywords

Bell jar; Calibration; Mercury vapour; Occupational exposure; Traceability; Uncertainty

Indexed keywords

BELLS; CALIBRATION; CONCENTRATION (PROCESS); MERCURY (METAL); UNCERTAINTY ANALYSIS;

EID: 54949116189     PISSN: 10739149     EISSN: 15256030     Source Type: Journal    
DOI: 10.1080/10739140802448309     Document Type: Article
Times cited : (8)

References (8)
  • 1
    • 0042400481 scopus 로고    scopus 로고
    • European Commission, Hg, Position Paper, Office for Official Publications of the European Communities, Luxembourg
    • European Commission, Ambient Air Pollution by Mercury (Hg): Position Paper, Office for Official Publications of the European Communities, Luxembourg, 2001.
    • (2001) Ambient Air Pollution by Mercury
  • 2
    • 0035505886 scopus 로고    scopus 로고
    • Gaseous elemental mercury as an indoor air pollutant
    • Carpi, A.; Chen, Y.F. Gaseous elemental mercury as an indoor air pollutant. Environ. Sci. Technol. 2001, 35 (21), 4170-4173.
    • (2001) Environ. Sci. Technol , vol.35 , Issue.21 , pp. 4170-4173
    • Carpi, A.1    Chen, Y.F.2
  • 4
    • 43949137564 scopus 로고    scopus 로고
    • Brown, R.J.C; Hood, D.; Brown, A.S. On the optimum sampling time for the measurement of pollutants in ambient air. J. Autom. Meth. Manag. 2008, Article ID 814715, 6 pages.
    • Brown, R.J.C; Hood, D.; Brown, A.S. On the optimum sampling time for the measurement of pollutants in ambient air. J. Autom. Meth. Manag. 2008, Article ID 814715, 6 pages.
  • 5
    • 40249093038 scopus 로고    scopus 로고
    • Brown, R.J.C; Brown, A.S.; Yardley, R.E.; Corns, W.T.; Stockwell, P.B. A practical uncertainty budget for ambient mercury vapour measurement. Atmos. Environ. 2008, 42(10), 2504-2517.
    • Brown, R.J.C; Brown, A.S.; Yardley, R.E.; Corns, W.T.; Stockwell, P.B. A practical uncertainty budget for ambient mercury vapour measurement. Atmos. Environ. 2008, 42(10), 2504-2517.
  • 6
    • 48249086587 scopus 로고    scopus 로고
    • Establishing SI traceability for measurements of mercury vapour
    • DOl:10.1039/b803724h
    • Brown, R.J.C; Brown, A.S.; Corns, W.T.; Stockwell, P.B. Establishing SI traceability for measurements of mercury vapour. Analyst 2008, 133, DOl:10.1039/b803724h.
    • (2008) Analyst , vol.133
    • Brown, R.J.C.1    Brown, A.S.2    Corns, W.T.3    Stockwell, P.B.4
  • 7
    • 54949156585 scopus 로고    scopus 로고
    • ISO 17852:2006, Water quality-Determination of mercury-Method using atomic fluorescence spectrometry; ISO Geneva, 2006.
    • ISO 17852:2006, Water quality-Determination of mercury-Method using atomic fluorescence spectrometry; ISO Geneva, 2006.
  • 8
    • 0000274917 scopus 로고
    • The accuracy of the vapour-injection calibration method for the determination of mercury by amalgamation/cold-vapour atomic absorption spectrometry
    • Dumarey, R.; Temmerman, E.; Dams, R.; Hoste, J. The accuracy of the vapour-injection calibration method for the determination of mercury by amalgamation/cold-vapour atomic absorption spectrometry. J. Anal. Chim. Acta 1985, 170, 337-340.
    • (1985) J. Anal. Chim. Acta , vol.170 , pp. 337-340
    • Dumarey, R.1    Temmerman, E.2    Dams, R.3    Hoste, J.4