Prolonged time to alarm in infusion devices operated at low flow rates

Author keywords

Critical care; Equipment alarm systems; Infusion pumps; Safety

Indexed keywords

ALARM MONITORING; ARTICLE; BIOMEDICAL ENGINEERING; CANADA; CLINICAL EVALUATION; CROSS-SECTIONAL STUDY; FLOW RATE; INFUSION PUMP; INTENSIVE CARE UNIT; MEASUREMENT; PRESSURE; PRIORITY JOURNAL; TEACHING HOSPITAL; TUBE; EQUIPMENT; EVALUATION; FEMALE; HUMAN; INSTRUMENTATION; INTRAVENOUS DRUG ADMINISTRATION; MALE; PULSATILE FLOW; RISK ASSESSMENT; SENSITIVITY AND SPECIFICITY; TIME;

EID: 54549114596     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0b013e31818698e3     Document Type: Article
Times cited : (6)

References (11)
  • 1
    • 0028044712 scopus 로고
    • Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures
    • Rooke GA, Bowdle TA: Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures. Anesth Analg 1994; 78:150-156
    • (1994) Anesth Analg , vol.78 , pp. 150-156
    • Rooke, G.A.1    Bowdle, T.A.2
  • 2
    • 33644803160 scopus 로고    scopus 로고
    • Selecting silicone tubing for device applications
    • Jahn D: Selecting silicone tubing for device applications. Med Device Technol 2005; 16: 12-13
    • (2005) Med Device Technol , vol.16 , pp. 12-13
    • Jahn, D.1
  • 3
    • 0344654720 scopus 로고    scopus 로고
    • Optimization of alarms: A study on alarm limits, alarm sounds, and false alarms, intended to reduce annoyance
    • Block FEJ, Nuutinen L, Ballast B: Optimization of alarms: A study on alarm limits, alarm sounds, and false alarms, intended to reduce annoyance. J Clin Monit Comput 1999; 15: 75-83
    • (1999) J Clin Monit Comput , vol.15 , pp. 75-83
    • Block, F.E.J.1    Nuutinen, L.2    Ballast, B.3
  • 4
    • 0028808155 scopus 로고
    • Human probability matching behavior in response to alarms of varying reliability
    • Bliss JP, Gilson RD, Deaton JE: Human probability matching behavior in response to alarms of varying reliability. Ergonomics 1995; 38:2300-2312
    • (1995) Ergonomics , vol.38 , pp. 2300-2312
    • Bliss, J.P.1    Gilson, R.D.2    Deaton, J.E.3
  • 5
    • 0033824074 scopus 로고    scopus 로고
    • Behavioral implications of alarm mistrust as a function of task workload
    • Bliss JP, Dunn MC: Behavioral implications of alarm mistrust as a function of task workload. Ergonomics 2000; 43:1283-1300
    • (2000) Ergonomics , vol.43 , pp. 1283-1300
    • Bliss, J.P.1    Dunn, M.C.2
  • 6
    • 0026691664 scopus 로고
    • Effect of two different syringes on syringe driver function
    • Clinton CW, Morrell DF: Effect of two different syringes on syringe driver function. S Afr J Surg 1992; 30:7-9
    • (1992) S Afr J Surg , vol.30 , pp. 7-9
    • Clinton, C.W.1    Morrell, D.F.2
  • 7
    • 0031887143 scopus 로고    scopus 로고
    • Causes of failure and dangers in the use of motor driven infusion pumps: Accidental closure of the infusion system
    • Heise D, Rathgeber J, Kettler D: Causes of failure and dangers in the use of motor driven infusion pumps: Accidental closure of the infusion system. Anaesthesist 1998; 47: 54-58
    • (1998) Anaesthesist , vol.47 , pp. 54-58
    • Heise, D.1    Rathgeber, J.2    Kettler, D.3
  • 8
    • 0033936276 scopus 로고    scopus 로고
    • Influence of infusion line compliance on drug delivery rate during acute line loop formation
    • Weiss M, Banziger O, Neff T, et al: Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Med 2000; 26:776-779
    • (2000) Intensive Care Med , vol.26 , pp. 776-779
    • Weiss, M.1    Banziger, O.2    Neff, T.3
  • 9
    • 16244365196 scopus 로고    scopus 로고
    • Syringe pumps take too long to give occlusion alarm
    • Donmez A, Araz C, Kayhan Z: Syringe pumps take too long to give occlusion alarm. Paediatr Anaesth 2005; 15:293-296
    • (2005) Paediatr Anaesth , vol.15 , pp. 293-296
    • Donmez, A.1    Araz, C.2    Kayhan, Z.3
  • 10
    • 20644444803 scopus 로고    scopus 로고
    • Fewer but better auditory alarms will improve patient safety
    • Edworthy J, Hellier E: Fewer but better auditory alarms will improve patient safety. Qual Saf Health Care 2005; 14:212-215
    • (2005) Qual Saf Health Care , vol.14 , pp. 212-215
    • Edworthy, J.1    Hellier, E.2
  • 11
    • 67650365999 scopus 로고    scopus 로고
    • Health Products and Food Branch: Syringe infusion pumps-risk of delay in detection of downstream occlusion. Health Canada, 2006. Available from: http://www.hc-sc.gc.ca/dhp-mps/alt-formats/hpfb-dgpsa/pdf/medeff/ infusion-perfusion-pump-pompe-3-nth-aah-eng.pdf. Accessed August 20, 2008
    • Health Products and Food Branch: Syringe infusion pumps-risk of delay in detection of downstream occlusion. Health Canada, 2006. Available from: http://www.hc-sc.gc.ca/dhp-mps/alt-formats/hpfb-dgpsa/pdf/medeff/ infusion-perfusion-pump-pompe-3-nth-aah-eng.pdf. Accessed August 20, 2008


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.