The Sprint Fidelis lead fracture story: What do we really know and where do we go from here?

Author keywords

[No Author keywords available]

Indexed keywords

DEFIBRILLATION; DEFIBRILLATOR; EDITORIAL; ELECTRIC SHOCK; HEART PACING; HUMAN; IMPEDANCE; LEAD FRACTURE; PATIENT CARE; PRIORITY JOURNAL; PROSTHESIS FAILURE; RISK ASSESSMENT; RISK FACTOR; RISK REDUCTION;

EID: 54549099073     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2008.08.001     Document Type: Editorial
Times cited : (16)

References (16)
  • 1
    • 33749061476 scopus 로고    scopus 로고
    • Recommendations from the Heart Rhythm Society Task Force on Device Performance Policies and Guidelines
    • Carlson M.D., Wilkoff B.L., Maisel W.H., et al. Recommendations from the Heart Rhythm Society Task Force on Device Performance Policies and Guidelines. Heart Rhythm 3 (2006) 1250-1273
    • (2006) Heart Rhythm , vol.3 , pp. 1250-1273
    • Carlson, M.D.1    Wilkoff, B.L.2    Maisel, W.H.3
  • 2
    • 33746430581 scopus 로고    scopus 로고
    • Management of recalled pacemakers and implantable cardioverter-defibrillators. A decision analysis model
    • Amin M., Matchar D.B., Wood M.A., et al. Management of recalled pacemakers and implantable cardioverter-defibrillators. A decision analysis model. JAMA 296 (2006) 412-420
    • (2006) JAMA , vol.296 , pp. 412-420
    • Amin, M.1    Matchar, D.B.2    Wood, M.A.3
  • 3
    • 0029064911 scopus 로고
    • Multicenter experience with a bipolar tined polyurethane ventricular lead
    • Hayes D.L., Graham K.J., Irwin M., et al. Multicenter experience with a bipolar tined polyurethane ventricular lead. Pacing Clin Electrophysiol 18 (1995) 999-1004
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 999-1004
    • Hayes, D.L.1    Graham, K.J.2    Irwin, M.3
  • 4
    • 0030225735 scopus 로고    scopus 로고
    • Implantable transvenous cardioverter defibrillator leads: The dark side
    • Lawton J.S., Wood M.A., Gilligan D.M., et al. Implantable transvenous cardioverter defibrillator leads: The dark side. Pacing Clin Electrophysiol 19 (1996) 1273-1278
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 1273-1278
    • Lawton, J.S.1    Wood, M.A.2    Gilligan, D.M.3
  • 5
    • 44449116247 scopus 로고    scopus 로고
    • Necessity for surgical revision of defibrillator leads implanted long-term
    • Eckstein J., Koller M.T., Zabel M., et al. Necessity for surgical revision of defibrillator leads implanted long-term. Circulation 117 (2008) 2727-2733
    • (2008) Circulation , vol.117 , pp. 2727-2733
    • Eckstein, J.1    Koller, M.T.2    Zabel, M.3
  • 6
    • 37549023768 scopus 로고    scopus 로고
    • A European perspective on lead extraction: Part I
    • Kennergren C. A European perspective on lead extraction: Part I. Heart Rhythm 5 (2008) 160-162
    • (2008) Heart Rhythm , vol.5 , pp. 160-162
    • Kennergren, C.1
  • 7
    • 34250749315 scopus 로고    scopus 로고
    • Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead
    • Hauser R.G., Kallinen L.M., Almquist A.K., et al. Early failure of a small-diameter high-voltage implantable cardioverter-defibrillator lead. Heart Rhythm 4 (2008) 892-896
    • (2008) Heart Rhythm , vol.4 , pp. 892-896
    • Hauser, R.G.1    Kallinen, L.M.2    Almquist, A.K.3
  • 8
    • 54549123585 scopus 로고    scopus 로고
    • ™ leads. Available from http://www.medtronic.com/fidelis/appendixC.html.
    • ™ leads. Available from http://www.medtronic.com/fidelis/appendixC.html.
  • 9
    • 54549113329 scopus 로고    scopus 로고
    • Medtronic Inc. Sprint Fidelis lead performance update. May 7, 2008.
    • Medtronic Inc. Sprint Fidelis lead performance update. May 7, 2008.
  • 10
    • 53049105768 scopus 로고    scopus 로고
    • Accelerating risks of Fidelis lead fracture
    • Birnie D., Farwell D., Green M.S., et al. Accelerating risks of Fidelis lead fracture. Heart Rhythm 5 (2008) 1375-1379
    • (2008) Heart Rhythm , vol.5 , pp. 1375-1379
    • Birnie, D.1    Farwell, D.2    Green, M.S.3
  • 11
    • 34247186286 scopus 로고    scopus 로고
    • Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator
    • Danik S.B., Mansour M., Singh J., et al. Increased incidence of subacute lead perforation noted with one implantable cardioverter-defibrillator. Heart Rhythm 4 (2007) 439-442
    • (2007) Heart Rhythm , vol.4 , pp. 439-442
    • Danik, S.B.1    Mansour, M.2    Singh, J.3
  • 12
    • 42649141945 scopus 로고    scopus 로고
    • Outcome of the Fidelis implantable cardioverter-defibrillator lead advisory: a report from the Canadian Heart Rhythm Society Working Group on Device Advisories
    • Krahn A.D., Champagne J., Healey J.S., et al. Outcome of the Fidelis implantable cardioverter-defibrillator lead advisory: a report from the Canadian Heart Rhythm Society Working Group on Device Advisories. Heart Rhythm 5 (2008) 639-642
    • (2008) Heart Rhythm , vol.5 , pp. 639-642
    • Krahn, A.D.1    Champagne, J.2    Healey, J.S.3
  • 13
    • 7044237094 scopus 로고    scopus 로고
    • An algorithm to predict implantable cardioverter-defibrillator lead failure
    • Gunderson B.D., Patel A.S., Bounds C.S., et al. An algorithm to predict implantable cardioverter-defibrillator lead failure. J Am Coll Cardiol 44 (2004) 1898-1902
    • (2004) J Am Coll Cardiol , vol.44 , pp. 1898-1902
    • Gunderson, B.D.1    Patel, A.S.2    Bounds, C.S.3
  • 14
    • 54549106825 scopus 로고    scopus 로고
    • Algorithm for early identification of Sprint Fidelis ICD Lead Fractures
    • Ellenbogen K.A., Gunderson B.D., Ousdigian K.T., et al. Algorithm for early identification of Sprint Fidelis ICD Lead Fractures. Heart Rhythm 5 (2008) S33
    • (2008) Heart Rhythm , vol.5
    • Ellenbogen, K.A.1    Gunderson, B.D.2    Ousdigian, K.T.3
  • 15
    • 46349091062 scopus 로고    scopus 로고
    • Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead
    • Kallinen L.M., Hauser R.G., Lee K.W., et al. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead. Heart Rhythm 5 (2008) 775-779
    • (2008) Heart Rhythm , vol.5 , pp. 775-779
    • Kallinen, L.M.1    Hauser, R.G.2    Lee, K.W.3
  • 16
    • 54549094893 scopus 로고    scopus 로고
    • Inappropriate shocks due to Sprint Fidelis ICD lead fracture may be reduced by programming more intervals for detection of ventricular fibrillation
    • Swerdlow C.D., Stadler R.W., Jackson T.E., et al. Inappropriate shocks due to Sprint Fidelis ICD lead fracture may be reduced by programming more intervals for detection of ventricular fibrillation. Heart Rhythm 5 (2008) S33
    • (2008) Heart Rhythm , vol.5
    • Swerdlow, C.D.1    Stadler, R.W.2    Jackson, T.E.3