메뉴 건너뛰기




Volumn 31, Issue 3, 2008, Pages 226-234

An experimental study on using a diagnostic computed radiography system as a quality assurance tool in radiotherapy

Author keywords

Computed radiography; Photostimulable phosphor plate; Quality assurance; Radiation isocentre size; Winston Lutz aligment tool

Indexed keywords

BIOMEDICAL ENGINEERING; COST EFFECTIVENESS; MEDICINE; QUALITY ASSURANCE; RADIOGRAPHY; RADIOTHERAPY;

EID: 54449101438     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03179349     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 0034810198 scopus 로고    scopus 로고
    • Portal imaging
    • Langmack, K.A., Portal imaging. Br J Radiol., 74(885): p. 789-804, 2001.
    • (2001) Br J Radiol , vol.74 , Issue.885 , pp. 789-804
    • Langmack, K.A.1
  • 2
    • 0020603401 scopus 로고
    • Computed radiography utilizing scanning laser stimulated luminescence
    • Sonoda, M., Takano, M., Miyahara, J. and Kato, H., Computed radiography utilizing scanning laser stimulated luminescence. Radiology, 148(3): p. 833-8, 1983.
    • (1983) Radiology , vol.148 , Issue.3 , pp. 833-838
    • Sonoda, M.1    Takano, M.2    Miyahara, J.3    Kato, H.4
  • 3
    • 0023191530 scopus 로고
    • Megavoltage portal films using computed radiographic imaging with photostimulable phosphors
    • Wilenzick, R.M., C.R. Merritt, and S. Balter, Megavoltage portal films using computed radiographic imaging with photostimulable phosphors. Med Phys, 14(3): p. 389-92, 1987.
    • (1987) Med Phys , vol.14 , Issue.3 , pp. 389-392
    • Wilenzick, R.M.1    Merritt, C.R.2    Balter, S.3
  • 4
    • 0024584101 scopus 로고
    • The use of storage phosphors for portal imaging in radiation therapy: Therapists' perception of image quality
    • Gur, D., Deutsch, M., Fuhrman, C.R., Clayton, P.A., Weiser, J.C., Rosenthal, M.S. and Bukovitz, A.G., The use of storage phosphors for portal imaging in radiation therapy: therapists' perception of image quality. Med Phys, 16(1): p. 132-6, 1989.
    • (1989) Med Phys , vol.16 , Issue.1 , pp. 132-136
    • Gur, D.1    Deutsch, M.2    Fuhrman, C.R.3    Clayton, P.A.4    Weiser, J.C.5    Rosenthal, M.S.6    Bukovitz, A.G.7
  • 5
    • 85024954447 scopus 로고    scopus 로고
    • Verification of prostate treatment setup using computed radiography for portal imaging
    • Whittington, R., Bloch, P., Hutchinson, D. and Bjarngard, B.E., Verification of prostate treatment setup using computed radiography for portal imaging. J Appl Clin Med Phys, 3(2): p. 88-96, 2002.
    • (2002) J Appl Clin Med Phys , vol.3 , Issue.2 , pp. 88-96
    • Whittington, R.1    Bloch, P.2    Hutchinson, D.3    Bjarngard, B.E.4
  • 6
    • 0030855664 scopus 로고    scopus 로고
    • Curtin-Savard, A.a.P., E.B., An electronic portal imaging device as a physics tool, Med Dosim, 22(2): p. 101-5, 1997.
    • Curtin-Savard, A.a.P., E.B., An electronic portal imaging device as a physics tool, Med Dosim, 22(2): p. 101-5, 1997.
  • 7
    • 0032914529 scopus 로고    scopus 로고
    • A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device
    • Dunscombe, P., Humphreys, S. and Leszczynski, K., A test tool for the visual verification of light and radiation fields using film or an electronic portal imaging device. Med Phys, 26(2): p. 239-43, 1999.
    • (1999) Med Phys , vol.26 , Issue.2 , pp. 239-243
    • Dunscombe, P.1    Humphreys, S.2    Leszczynski, K.3
  • 8
    • 8744271379 scopus 로고    scopus 로고
    • The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID)
    • Liu, G., van Doorn, T., and E. Bezak, The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID). Australas Phys Eng Sci Med., 27(3): p. 111-117, 2004.
    • (2004) Australas Phys Eng Sci Med , vol.27 , Issue.3 , pp. 111-117
    • Liu, G.1    van Doorn, T.2    Bezak, E.3
  • 9
    • 25644457670 scopus 로고    scopus 로고
    • Evaluation of a computed radiography system for megavoltage photon beam dosimetry
    • Olch, A.J., Evaluation of a computed radiography system for megavoltage photon beam dosimetry. Med Phys, 32(9): p. 2987-99, 2005.
    • (2005) Med Phys , vol.32 , Issue.9 , pp. 2987-2999
    • Olch, A.J.1
  • 10
    • 0033147771 scopus 로고    scopus 로고
    • Photostimulable x-ray storage phosphors: A review of present understanding
    • Seggern, H.V., Photostimulable x-ray storage phosphors: a review of present understanding. Braz. J. Phys., 29(2): p. 254-268, 1999.
    • (1999) Braz. J. Phys , vol.29 , Issue.2 , pp. 254-268
    • Seggern, H.V.1
  • 11
    • 85036878618 scopus 로고    scopus 로고
    • Rasband, W.S., ImageJ, U.S.N.I.o. Health, Editor, http://rsb.info.nih.gov/ij/: Bethesda, Maryland, USA, 2005.
    • Rasband, W.S., ImageJ, U.S.N.I.o. Health, Editor, http://rsb.info.nih.gov/ij/: Bethesda, Maryland, USA, 2005.
  • 12
    • 3042643032 scopus 로고    scopus 로고
    • A procedure to determine the radiation isocenter size in a linear accelerator
    • Gonzalez, A., Castro, I. and Martinez, J.A., A procedure to determine the radiation isocenter size in a linear accelerator. Med Phys, 31(6): p. 1489-93, 2004.
    • (2004) Med Phys , vol.31 , Issue.6 , pp. 1489-1493
    • Gonzalez, A.1    Castro, I.2    Martinez, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.