-
1
-
-
33845314342
-
Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging
-
Altes T.A., Mata J., de Lange E.E., Brookeman J.R., and Mugler J.P. Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging. J. Magn. Reson. Imaging: JMRI 24 6 (2006) 1277-1283
-
(2006)
J. Magn. Reson. Imaging: JMRI
, vol.24
, Issue.6
, pp. 1277-1283
-
-
Altes, T.A.1
Mata, J.2
de Lange, E.E.3
Brookeman, J.R.4
Mugler, J.P.5
-
2
-
-
54449092754
-
-
Analyse-It, 2008. Analyse-it for Microsoft Excel (version 2.07) Analyse-it Software. Ltd. .
-
Analyse-It, 2008. Analyse-it for Microsoft Excel (version 2.07) Analyse-it Software. Ltd. .
-
-
-
-
3
-
-
0018375707
-
Regional ventilatory clearance by xenon scintigraphy: a critical evaluation of two estimation procedures
-
Bunow B., Line B., Horton M., and Weiss G. Regional ventilatory clearance by xenon scintigraphy: a critical evaluation of two estimation procedures. J. Nucl. Med. 20 7 (1979) 703-710
-
(1979)
J. Nucl. Med.
, vol.20
, Issue.7
, pp. 703-710
-
-
Bunow, B.1
Line, B.2
Horton, M.3
Weiss, G.4
-
4
-
-
34147169594
-
Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements
-
Chon D., Beck K.C., Simon B.A., Shikata H., Saba O.I., and Hoffman E.A. Effect of low-xenon and krypton supplementation on signal/noise of regional CT-based ventilation measurements. J. Appl. Physiol. 102 (2007) 1535-1544
-
(2007)
J. Appl. Physiol.
, vol.102
, pp. 1535-1544
-
-
Chon, D.1
Beck, K.C.2
Simon, B.A.3
Shikata, H.4
Saba, O.I.5
Hoffman, E.A.6
-
5
-
-
23744510690
-
Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies
-
Chon D., Simon B.A., Beck K.C., Shikata H., Saba O.I., Won C., and Hoffman E.A. Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies. Resp. Physiol. Neurobiol. 148 (2005) 65-83
-
(2005)
Resp. Physiol. Neurobiol.
, vol.148
, pp. 65-83
-
-
Chon, D.1
Simon, B.A.2
Beck, K.C.3
Shikata, H.4
Saba, O.I.5
Won, C.6
Hoffman, E.A.7
-
7
-
-
34447302335
-
Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry
-
Christensen G.E., Song J.H., Lu W., Naqa I.E., and Low D.A. Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry. Med. Phys. 34 6 (2007) 2155-2165
-
(2007)
Med. Phys.
, vol.34
, Issue.6
, pp. 2155-2165
-
-
Christensen, G.E.1
Song, J.H.2
Lu, W.3
Naqa, I.E.4
Low, D.A.5
-
8
-
-
33645518119
-
Dynamic ventilation imaging from four-dimensional computed tomography
-
Guerrero T., Sanders K., Castillo E., Zhang Y., Bidaut L., and Komaki T.P.R. Dynamic ventilation imaging from four-dimensional computed tomography. Phys. Med. Biol. 51 4 (2006) 777-791
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.4
, pp. 777-791
-
-
Guerrero, T.1
Sanders, K.2
Castillo, E.3
Zhang, Y.4
Bidaut, L.5
Komaki, T.P.R.6
-
9
-
-
20344375442
-
Quantification of regional ventilation from treatment planning CT
-
Guerrero T., Sanders K., Noyola-Martinez J., Castillo E., Zhang Y., Tapia R., Guerra R., Borghero Y., and Komaki R. Quantification of regional ventilation from treatment planning CT. Int. J. Radiat. Oncol. Biol. Phys. 62 3 (2005) 630-634
-
(2005)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.62
, Issue.3
, pp. 630-634
-
-
Guerrero, T.1
Sanders, K.2
Noyola-Martinez, J.3
Castillo, E.4
Zhang, Y.5
Tapia, R.6
Guerra, R.7
Borghero, Y.8
Komaki, R.9
-
10
-
-
0010232543
-
Computer-aided analysis of regional lung air content using three-dimensional computed tomographic images and multinominal models
-
Hoffman E.A., Acharya R.S., and Wollins J.A. Computer-aided analysis of regional lung air content using three-dimensional computed tomographic images and multinominal models. Int. J. Math. Model. 7 5-8 (1986) 1099-1116
-
(1986)
Int. J. Math. Model.
, vol.7
, Issue.5-8
, pp. 1099-1116
-
-
Hoffman, E.A.1
Acharya, R.S.2
Wollins, J.A.3
-
11
-
-
0020565594
-
Estimation of pleural surface expansile forces in intact dogs
-
Hoffman E.A., Behrenbeck T., Chevalier P.A., and Wood E.H. Estimation of pleural surface expansile forces in intact dogs. J. Appl. Physiol. 55 3 (1983) 935-948
-
(1983)
J. Appl. Physiol.
, vol.55
, Issue.3
, pp. 935-948
-
-
Hoffman, E.A.1
Behrenbeck, T.2
Chevalier, P.A.3
Wood, E.H.4
-
12
-
-
10744220284
-
Characterization of the interstitial lung diseases via density-based and texture-based analysis of computed tomography images of lung structure and function
-
Hoffman E.A., Reinhardt J.M., Sonka M., Simon B.A., Guo J., Saba O., Chon D., Samrah S., Shikata H., Tschirren J., Pálagyi K., Beck K.C., and McLennan G. Characterization of the interstitial lung diseases via density-based and texture-based analysis of computed tomography images of lung structure and function. Acad. Radiol. 10 10 (2003) 1104-1118
-
(2003)
Acad. Radiol.
, vol.10
, Issue.10
, pp. 1104-1118
-
-
Hoffman, E.A.1
Reinhardt, J.M.2
Sonka, M.3
Simon, B.A.4
Guo, J.5
Saba, O.6
Chon, D.7
Samrah, S.8
Shikata, H.9
Tschirren, J.10
Pálagyi, K.11
Beck, K.C.12
McLennan, G.13
-
13
-
-
0022253332
-
Effect of body orientation on regional lung expansion in dog and sloth
-
Hoffman E.A., and Ritman E.L. Effect of body orientation on regional lung expansion in dog and sloth. J. Appl. Physiol. 59 2 (1985) 481-491
-
(1985)
J. Appl. Physiol.
, vol.59
, Issue.2
, pp. 481-491
-
-
Hoffman, E.A.1
Ritman, E.L.2
-
14
-
-
0020759982
-
Noninvasive quantitative imaging of shape and volume of lungs
-
Hoffman E.A., Sinak L.J., Robb R.A., and Ritman E.L. Noninvasive quantitative imaging of shape and volume of lungs. J. Appl. Physiol. 54 5 (1983) 1414-1421
-
(1983)
J. Appl. Physiol.
, vol.54
, Issue.5
, pp. 1414-1421
-
-
Hoffman, E.A.1
Sinak, L.J.2
Robb, R.A.3
Ritman, E.L.4
-
15
-
-
0028909934
-
Matching pulmonary structure and perfusion via combined dynamic multislice CT and thin-slice high-resolution CT
-
Hoffman E.A., Tajik J.K., and Kugelmass S.D. Matching pulmonary structure and perfusion via combined dynamic multislice CT and thin-slice high-resolution CT. Comp. Med. Imaging Graph. 19 (1995) 101-112
-
(1995)
Comp. Med. Imaging Graph.
, vol.19
, pp. 101-112
-
-
Hoffman, E.A.1
Tajik, J.K.2
Kugelmass, S.D.3
-
16
-
-
0035354205
-
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
-
Hu S., Hoffman E.A., and Reinhardt J.M. Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images. IEEE Trans. Med. Imaging 20 6 (2001) 490-498
-
(2001)
IEEE Trans. Med. Imaging
, vol.20
, Issue.6
, pp. 490-498
-
-
Hu, S.1
Hoffman, E.A.2
Reinhardt, J.M.3
-
17
-
-
0020628873
-
Topographical distribution of regional lung volume in anesthetized dogs
-
Hubmayr R., Walters B., Chevalier P., Rodarte J., and Olson L. Topographical distribution of regional lung volume in anesthetized dogs. J. Appl. Physiol. 54 4 (1983) 1048-1056
-
(1983)
J. Appl. Physiol.
, vol.54
, Issue.4
, pp. 1048-1056
-
-
Hubmayr, R.1
Walters, B.2
Chevalier, P.3
Rodarte, J.4
Olson, L.5
-
18
-
-
0023574785
-
Regional ventilation during spontaneous breathing and mechanical ventilation in dogs
-
Hubmayr R.D., Rodarte J.R., Walters B.J., and Tonelli F.M. Regional ventilation during spontaneous breathing and mechanical ventilation in dogs. J. Appl. Physiol. 63 6 (1987) 2467-2475
-
(1987)
J. Appl. Physiol.
, vol.63
, Issue.6
, pp. 2467-2475
-
-
Hubmayr, R.D.1
Rodarte, J.R.2
Walters, B.J.3
Tonelli, F.M.4
-
19
-
-
0036557904
-
Consistent landmark and intensity-based image registration
-
Johnson H., and Christensen G. Consistent landmark and intensity-based image registration. IEEE Trans. Med. Imaging 21 5 (2002) 450-461
-
(2002)
IEEE Trans. Med. Imaging
, vol.21
, Issue.5
, pp. 450-461
-
-
Johnson, H.1
Christensen, G.2
-
20
-
-
0035143503
-
Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs
-
Marcucci C., Nyhan D., and Simon B.A. Distribution of pulmonary ventilation using Xe-enhanced computed tomography in prone and supine dogs. J. Appl. Physiol. 90 2 (2001) 421-430
-
(2001)
J. Appl. Physiol.
, vol.90
, Issue.2
, pp. 421-430
-
-
Marcucci, C.1
Nyhan, D.2
Simon, B.A.3
-
21
-
-
0033967320
-
General Deming regression for estimating systematic bias and its confidence interval in method-comparison studies
-
Martin R.F. General Deming regression for estimating systematic bias and its confidence interval in method-comparison studies. Clin. Chem. 46 1 (2000) 100-104
-
(2000)
Clin. Chem.
, vol.46
, Issue.1
, pp. 100-104
-
-
Martin, R.F.1
-
22
-
-
0013911980
-
Regional distribution of inspired gas in the lung
-
Milic-Emili J., Henderson J.A., Dolovich M.B., Trop D., and Kaneko K. Regional distribution of inspired gas in the lung. J. Appl. Physiol. 21 (1966) 749-759
-
(1966)
J. Appl. Physiol.
, vol.21
, pp. 749-759
-
-
Milic-Emili, J.1
Henderson, J.A.2
Dolovich, M.B.3
Trop, D.4
Kaneko, K.5
-
23
-
-
36148998718
-
Hyperpolarized (129)xe mri: a viable functional lung imaging modality?
-
Patz S., Hersman F.W., Muradian I., Hrovat M.I., Ruset I.C., Ketel S., Jacobson F., Topulos G.P., Hatabu H., and Butler J.P. Hyperpolarized (129)xe mri: a viable functional lung imaging modality?. Eur. J. Radiol. 64 3 (2007) 335-344
-
(2007)
Eur. J. Radiol.
, vol.64
, Issue.3
, pp. 335-344
-
-
Patz, S.1
Hersman, F.W.2
Muradian, I.3
Hrovat, M.I.4
Ruset, I.C.5
Ketel, S.6
Jacobson, F.7
Topulos, G.P.8
Hatabu, H.9
Butler, J.P.10
-
24
-
-
38149075977
-
Registration-derived estimates of local lung expansion as surrogates for regional ventilation
-
Karssemeijer N., and Lelieveldt B. (Eds), Springer-Verlag, Utrecht
-
Reinhardt J.M., Christensen G.E., Hoffman E.A., Ding K., and Cao K. Registration-derived estimates of local lung expansion as surrogates for regional ventilation. In: Karssemeijer N., and Lelieveldt B. (Eds). Lecture Notes in Computer Science vol. 4584 (2007), Springer-Verlag, Utrecht 763-774
-
(2007)
Lecture Notes in Computer Science
, vol.4584
, pp. 763-774
-
-
Reinhardt, J.M.1
Christensen, G.E.2
Hoffman, E.A.3
Ding, K.4
Cao, K.5
-
25
-
-
0030895939
-
High-resolution maps of regional ventilation utilizing inhaled fluorescent microspheres
-
Robertson H.T., Glenny R.W., Stanford D., McInnes L.M., Luchtel D.L., and Covert D. High-resolution maps of regional ventilation utilizing inhaled fluorescent microspheres. J. Appl. Physiol. 82 3 (1997) 943-953
-
(1997)
J. Appl. Physiol.
, vol.82
, Issue.3
, pp. 943-953
-
-
Robertson, H.T.1
Glenny, R.W.2
Stanford, D.3
McInnes, L.M.4
Luchtel, D.L.5
Covert, D.6
-
26
-
-
0021860979
-
Regional lung strain in dogs during deflation from total lung capacity
-
Rodarte J.R., Hubmayr R.D., Stamenovic D., and Walters B.J. Regional lung strain in dogs during deflation from total lung capacity. J. Appl. Physiol. 58 1 (1985) 164-172
-
(1985)
J. Appl. Physiol.
, vol.58
, Issue.1
, pp. 164-172
-
-
Rodarte, J.R.1
Hubmayr, R.D.2
Stamenovic, D.3
Walters, B.J.4
-
27
-
-
0031915554
-
Parameter estimation and confidence intervals for Xe-CT ventilation studies: a Monte Carlo approach
-
Simon B.A., and Marcucci C. Parameter estimation and confidence intervals for Xe-CT ventilation studies: a Monte Carlo approach. J. Appl. Physiol. 84 2 (1998) 709-716
-
(1998)
J. Appl. Physiol.
, vol.84
, Issue.2
, pp. 709-716
-
-
Simon, B.A.1
Marcucci, C.2
-
28
-
-
27144546739
-
Towards a model of lung biomechanics: pulmonary kinematics via registration of serial lung images
-
Sundaram T.A., and Gee J.C. Towards a model of lung biomechanics: pulmonary kinematics via registration of serial lung images. Med. Image Anal. 9 6 (2005) 524-537
-
(2005)
Med. Image Anal.
, vol.9
, Issue.6
, pp. 524-537
-
-
Sundaram, T.A.1
Gee, J.C.2
-
29
-
-
0036183857
-
Subsecond multisection CT of regional pulmonary ventilation
-
Tajik J.K., Chon D., Won C.-H., Tran B.Q., and Hoffman E.A. Subsecond multisection CT of regional pulmonary ventilation. Acad. Radiol. 9 (2002) 130-146
-
(2002)
Acad. Radiol.
, vol.9
, pp. 130-146
-
-
Tajik, J.K.1
Chon, D.2
Won, C.-H.3
Tran, B.Q.4
Hoffman, E.A.5
-
30
-
-
0021686479
-
Nitrogen-13 and xenon-133 ventilation studies
-
van der Mark T.W., Rookmaker A.E., Kiers A., Peset R., Vaalburg W., Paans A.M., and Woldring M.G. Nitrogen-13 and xenon-133 ventilation studies. J. Nucl. Med. 25 11 (1984) 1175-1182
-
(1984)
J. Nucl. Med.
, vol.25
, Issue.11
, pp. 1175-1182
-
-
van der Mark, T.W.1
Rookmaker, A.E.2
Kiers, A.3
Peset, R.4
Vaalburg, W.5
Paans, A.M.6
Woldring, M.G.7
-
31
-
-
0037686665
-
Dynamic radial projection mri of inhaled hyperpolarized 3he gas
-
Wild J.M., Paley M.N.J., Kasuboski L., Swift A., Fichele S., Woodhouse N., Griffiths P.D., and van Beek E.J.R. Dynamic radial projection mri of inhaled hyperpolarized 3he gas. Magnetic Resonance in Medicine: Official Journal of the Society of Magnetic Resonance in Medicine/Society of Magnetic Resonance in Medicine 49 6 (2003) 991-997
-
(2003)
Magnetic Resonance in Medicine: Official Journal of the Society of Magnetic Resonance in Medicine/Society of Magnetic Resonance in Medicine
, vol.49
, Issue.6
, pp. 991-997
-
-
Wild, J.M.1
Paley, M.N.J.2
Kasuboski, L.3
Swift, A.4
Fichele, S.5
Woodhouse, N.6
Griffiths, P.D.7
van Beek, E.J.R.8
-
32
-
-
15944390515
-
Combined helium-3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never-smokers
-
Woodhouse N., Wild J.M., Paley M.N.J., Fichele S., Said Z., Swift A.J., and van Beek E.J.R. Combined helium-3/proton magnetic resonance imaging measurement of ventilated lung volumes in smokers compared to never-smokers. J. Magn. Reson. Imaging: JMRI 21 4 (2005) 365-369
-
(2005)
J. Magn. Reson. Imaging: JMRI
, vol.21
, Issue.4
, pp. 365-369
-
-
Woodhouse, N.1
Wild, J.M.2
Paley, M.N.J.3
Fichele, S.4
Said, Z.5
Swift, A.J.6
van Beek, E.J.R.7
|