Correction for Resolution Nonuniformities Caused by Anode Angulation in Computed Tomography

Author keywords

Computed tomography (CT); sinogram restoration

Indexed keywords

ALGORITHM; ARTICLE; ARTIFACT; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; ELECTRODE; EQUIPMENT; EQUIPMENT DESIGN; EVALUATION; IMAGE QUALITY; INSTRUMENTATION; METHODOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 54449099616     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.2008.923639     Document Type: Article
Times cited : (20)

References (8)
  • 1
    • 0003543948 scopus 로고    scopus 로고
    • The Essential Physics of Medical Imaging
    • Philadelphia, PA: Lippincott Williams Wilkins
    • J. T. Bushberg, J. A. Seibert, E. M. Leidholt, Jr., and J. M. Boone, The Essential Physics of Medical Imaging. Philadelphia, PA: Lippincott Williams Wilkins, 2002.
    • (2002)
    • Bushberg, J.T.1    Seibert, J.A.2    Leidholt, E.M.3    Boone, J.M.4
  • 2
    • 0003734872 scopus 로고    scopus 로고
    • Computed Tomography: Principles, Design, Artifacts, and Recent Advances
    • Bellingham: SPIE Press
    • J. Hsieh, Computed Tomography: Principles, Design, Artifacts, and Recent Advances. Bellingham: SPIE Press, 2003.
    • (2003)
    • Hsieh, J.1
  • 3
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C. R. Crawford and K. F. King, “Computed tomography scanning with simultaneous patient translation,” Med. Phys., vol. 17, pp. 967–982, 1990.
    • (1990) Med. Phys. , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 4
    • 33746927954 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram restoration for computed tomography
    • Aug.
    • P. J. La Rivière, J. Bian, and P. Vargas, “Penalized-likelihood sinogram restoration for computed tomography,” IEEE Trans. Med. Imag., vol. 25, no. 8, pp. 1022–1036, Aug. 2006.
    • (2006) IEEE Trans. Med. Imag. , vol.25 , Issue.8 , pp. 1022-1036
    • La Rivière, P.J.1    Bian, J.2    Vargas, P.3
  • 5
    • 0018819516 scopus 로고
    • Nonlinear partial volume artifacts in x-ray computed tomography
    • G. H. Glover and N. J. Pelc, “Nonlinear partial volume artifacts in x-ray computed tomography,” Med. Phys., vol. 7, pp. 238–248, 1980.
    • (1980) Med. Phys. , vol.7 , pp. 238-248
    • Glover, G.H.1    Pelc, N.J.2
  • 6
    • 0003735899 scopus 로고
    • Principles of Computerized Tomography Imaging
    • New York: IEEE Press
    • A. C. Kak and M. Slaney, Principles of Computerized Tomography Imaging. New York: IEEE Press, 1988.
    • (1988)
    • Kak, A.C.1    Slaney, M.2
  • 7
    • 0032912583 scopus 로고    scopus 로고
    • Optimal noise control in and fast reconstruction of fan-beam computed tomography image
    • X. Pan, “Optimal noise control in and fast reconstruction of fan-beam computed tomography image,” Med. Phys., vol. 26, pp. 689–697, 1999.
    • (1999) Med. Phys. , vol.26 , pp. 689-697
    • Pan, X.1
  • 8
    • 0002638197 scopus 로고    scopus 로고
    • Statistical image reconstruction methods for transmission tomography
    • J. M. Fitzpatrick and M. Sonka, Eds. Bellingham, WA: SPIE Press
    • J. A. Fessler, “Statistical image reconstruction methods for transmission tomography,” in Handbook of Medical Imaging, J. M. Fitzpatrick and M. Sonka, Eds. Bellingham, WA: SPIE Press, 2000, vol. 2, pp. 1–70.
    • (2000) Handbook of Medical Imaging , vol.2 , pp. 1-70
    • Fessler, J.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.