메뉴 건너뛰기




Volumn E87-C, Issue 9, 2004, Pages 1640-1642

Cryogenic Whispering Gallery sapphire oscillator for microwave frequency standard applications

Author keywords

4 K pulse tube cryocooler; Frequency stability; Microwave oscillator; Sapphire; Whispering gallery mode

Indexed keywords

CRYOGENIC EQUIPMENT; ELECTRIC CONNECTORS; MICROWAVES; NATURAL FREQUENCIES; Q FACTOR MEASUREMENT; RESONANCE; SAPPHIRE; THERMAL NOISE;

EID: 5444260692     PISSN: 09168524     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (11)
  • 1
    • 0033887366 scopus 로고    scopus 로고
    • Improved cryogenic sapphire oscillator with exceptionally high frequency stability
    • S. Chang, A.G. Mann, and A.N. Luiten, "Improved cryogenic sapphire oscillator with exceptionally high frequency stability," Electron. Lett., vol.36, no.5, pp.480-481, 2000.
    • (2000) Electron. Lett. , vol.36 , Issue.5 , pp. 480-481
    • Chang, S.1    Mann, A.G.2    Luiten, A.N.3
  • 2
    • 0034263091 scopus 로고    scopus 로고
    • Stability and phase noise tests of two cryo-cooled sapphire oscillators
    • G.J. Dick and R.T. Wang, "Stability and phase noise tests of two cryo-cooled sapphire oscillators," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol.47, no.5, pp.1098-1101, 2000.
    • (2000) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.47 , Issue.5 , pp. 1098-1101
    • Dick, G.J.1    Wang, R.T.2
  • 4
    • 0000012285 scopus 로고    scopus 로고
    • Cryocooled sapphire oscillator with ultrahigh stability
    • R.T. Wang and G.J. Dick, "Cryocooled sapphire oscillator with ultrahigh stability," IEEE Trans. Instrum. Meas., vol.48, no.2, pp.528-531, 1999.
    • (1999) IEEE Trans. Instrum. Meas. , vol.48 , Issue.2 , pp. 528-531
    • Wang, R.T.1    Dick, G.J.2
  • 7
    • 0026388035 scopus 로고
    • Resonant frequencies of high order modes in cylindrical anisotropic dielectric resonators
    • M.E. Tobar and A.G. Mann, "Resonant frequencies of high order modes in cylindrical anisotropic dielectric resonators," IEEE Trans. Microw. Theory Tech., vol.39, no.12, pp.2077-2083, 1991.
    • (1991) IEEE Trans. Microw. Theory Tech. , vol.39 , Issue.12 , pp. 2077-2083
    • Tobar, M.E.1    Mann, A.G.2
  • 8
    • 0031269944 scopus 로고    scopus 로고
    • Magnetic field tuning of paramagnetic frequency-temperature compensation in cryogenic sapphire dielectric microwave resonators
    • R.P. Kovacich, A.G. Mann, and D.G. Blair, "Magnetic field tuning of paramagnetic frequency-temperature compensation in cryogenic sapphire dielectric microwave resonators," J. Phys. D, Appl. Phys., vol.30, pp.3146-3152, 1997.
    • (1997) J. Phys. D, Appl. Phys. , vol.30 , pp. 3146-3152
    • Kovacich, R.P.1    Mann, A.G.2    Blair, D.G.3
  • 9
    • 84897386934 scopus 로고
    • Statistics of atomic frequency standards
    • D.W. Allan, "Statistics of atomic frequency standards," Proc. IEEE, vol.54, pp.221-230, 1966.
    • (1966) Proc. IEEE , vol.54 , pp. 221-230
    • Allan, D.W.1
  • 10
    • 0020302570 scopus 로고
    • The active hydrogen maser: State of the art and forecast
    • J. Vanier, "The active hydrogen maser: State of the art and forecast," Metrologia, vol.18, pp.173-186, 1982.
    • (1982) Metrologia , vol.18 , pp. 173-186
    • Vanier, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.