메뉴 건너뛰기




Volumn 31, Issue 10, 2008, Pages 1423-1431

Portable monitoring and autotitration versus polysomnography for the diagnosis and treatment of sleep apnea

Author keywords

Auto titration positive airway pressure; CPAP; Portable monitoring; Sleep apnea

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL VENTILATION; AUTOTITRATING POSITIVE AIRWAY PRESSURE; CLINICAL TRIAL; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; EPWORTH SLEEPINESS SCALE; FEMALE; GLOBAL FUNCTIONAL OUTCOME OF SLEEP QUESTIONNAIRE SCORE; HUMAN; MAJOR CLINICAL STUDY; MALE; PATIENT MONITORING; PATIENT SATISFACTION; POLYSOMNOGRAPHY; PORTABLE MONITORING; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RATING SCALE; SLEEP APNEA SYNDROME; SOMNOLENCE;

EID: 54349092881     PISSN: 01618105     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (167)

References (34)
  • 2
    • 20144389345 scopus 로고    scopus 로고
    • Practice parameters for the indications for polysomnography and related procedures: An update for 2005
    • Kushida CA, Littner MR, Morgenthaler T, et al. Practice parameters for the indications for polysomnography and related procedures: an update for 2005. Sleep 2005:28:499-521.
    • (2005) Sleep , vol.28 , pp. 499-521
    • Kushida, C.A.1    Littner, M.R.2    Morgenthaler, T.3
  • 3
    • 33745789900 scopus 로고    scopus 로고
    • Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders
    • Kushida CA, Littner MR, Hirschkowitz M, et al. Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders. Sleep 2006;29:375-80.
    • (2006) Sleep , vol.29 , pp. 375-380
    • Kushida, C.A.1    Littner, M.R.2    Hirschkowitz, M.3
  • 4
    • 33745771560 scopus 로고    scopus 로고
    • Evaluation of positive airway pressure treatment for sleep related breathing disorders in adults
    • Gay P, Weaver T, Loube D, Iber C. Evaluation of positive airway pressure treatment for sleep related breathing disorders in adults. Sleep 2006;29:381-401.
    • (2006) Sleep , vol.29 , pp. 381-401
    • Gay, P.1    Weaver, T.2    Loube, D.3    Iber, C.4
  • 5
    • 0142074238 scopus 로고    scopus 로고
    • Home diagnosis of sleep apnea: A systematic review of the literature: an evidence based review
    • Flemons WW, Littner MR, Rowley JA, Gay P, et al. Home diagnosis of sleep apnea: a systematic review of the literature: an evidence based review. Chest 2003:124:1543-79.
    • (2003) Chest , vol.124 , pp. 1543-1579
    • Flemons, W.W.1    Littner, M.R.2    Rowley, J.A.3    Gay, P.4
  • 6
    • 1542434613 scopus 로고    scopus 로고
    • Practice parameters for use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults
    • Chesson AL Jr, Berry RB, Pack A. Practice parameters for use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults. Sleep 2003:26:907-13.
    • (2003) Sleep , vol.26 , pp. 907-913
    • Chesson Jr, A.L.1    Berry, R.B.2    Pack, A.3
  • 7
    • 2442472324 scopus 로고    scopus 로고
    • Executive summary on the systematic review and practice parameters for portable monitoring in investigation of suspected sleep apnea in adults. Am J Resp Crit Care Med 2004:169:1160-3
    • Executive summary on the systematic review and practice parameters for portable monitoring in investigation of suspected sleep apnea in adults. Am J Resp Crit Care Med 2004:169:1160-3.
  • 8
    • 38849206434 scopus 로고    scopus 로고
    • Clinical guidelines for the use of unattended portable monitoring in the diagnosis of obstructive sleep apnea in adult patients
    • Collop NA, Anderson WM, Boehlecke B, et al. Clinical guidelines for the use of unattended portable monitoring in the diagnosis of obstructive sleep apnea in adult patients. J Clin Sleep Med 2007;3:737-48.
    • (2007) J Clin Sleep Med , vol.3 , pp. 737-748
    • Collop, N.A.1    Anderson, W.M.2    Boehlecke, B.3
  • 9
    • 0037086989 scopus 로고    scopus 로고
    • The use of auto-titrating positive airway pressure for treatment of adult obstructive sleep apnea
    • Berry RB, Parish JM, Hartse KM. The use of auto-titrating positive airway pressure for treatment of adult obstructive sleep apnea. Sleep 2002;25:148-73.
    • (2002) Sleep , vol.25 , pp. 148-173
    • Berry, R.B.1    Parish, J.M.2    Hartse, K.M.3
  • 10
    • 0037087081 scopus 로고    scopus 로고
    • Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine Report
    • Littner M, Hirshkowitz M, Davila D, et al. Practice parameters for the use of auto-titrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. An American Academy of Sleep Medicine Report. Sleep 2002;25:143-7.
    • (2002) Sleep , vol.25 , pp. 143-147
    • Littner, M.1    Hirshkowitz, M.2    Davila, D.3
  • 11
    • 9644262327 scopus 로고    scopus 로고
    • Alternative methods of titrating continuous positive airway pressure
    • Masa JF, Jimenez A, Duran D, Capote F, et al. Alternative methods of titrating continuous positive airway pressure. Am J Respir Crit Care Med 2004:1218-24.
    • (2004) Am J Respir Crit Care Med , pp. 1218-1224
    • Masa, J.F.1    Jimenez, A.2    Duran, D.3    Capote, F.4
  • 12
    • 33847077680 scopus 로고    scopus 로고
    • Diagnosis and Initial management of Obstructive Sleep Apnea without polysomnography
    • Mulgrew AT, Fox N, Ayas NT, Ryan F. Diagnosis and Initial management of Obstructive Sleep Apnea without polysomnography. Ann Intern Med 2007:146:157-66.
    • (2007) Ann Intern Med , vol.146 , pp. 157-166
    • Mulgrew, A.T.1    Fox, N.2    Ayas, N.T.3    Ryan, F.4
  • 13
    • 12144257779 scopus 로고    scopus 로고
    • Clinical usefulness of home oximetry compared with polysomnography for assessment of sleep apnea
    • Whitelaw WA, Brant RF. Flemons WW. Clinical usefulness of home oximetry compared with polysomnography for assessment of sleep apnea. Am J Respir Crit Care Med 2005:171:188-93.
    • (2005) Am J Respir Crit Care Med , vol.171 , pp. 188-193
    • Whitelaw, W.A.1    Brant, R.F.2    Flemons, W.W.3
  • 14
    • 25144481980 scopus 로고    scopus 로고
    • Sleep problems and the risk for sleep disorders in an outpatient veteran population
    • Mustafa M, Erokwu N, Ebose I, Strohl, K. Sleep problems and the risk for sleep disorders in an outpatient veteran population. Sleep Breath 2005:9:57-63.
    • (2005) Sleep Breath , vol.9 , pp. 57-63
    • Mustafa, M.1    Erokwu, N.2    Ebose, I.3    Strohl, K.4
  • 15
    • 0026333617 scopus 로고
    • A new method for measuring daytime sleepiness: The Epworth sleepiness scale
    • Johns MW. A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep 1991:14:540-5.
    • (1991) Sleep , vol.14 , pp. 540-545
    • Johns, M.W.1
  • 16
    • 0037102116 scopus 로고    scopus 로고
    • Obstructive sleep apnea
    • Flemons WW. Obstructive sleep apnea. N Engl J Med 2002:347:498-504.
    • (2002) N Engl J Med , vol.347 , pp. 498-504
    • Flemons, W.W.1
  • 19
    • 0033178851 scopus 로고    scopus 로고
    • Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research. The Report of the American Academy of Sleep Medicine Task Force
    • Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of the American Academy of Sleep Medicine Task Force. Sleep 1999;22:667-89.
    • (1999) Sleep , vol.22 , pp. 667-689
  • 20
    • 4143081465 scopus 로고    scopus 로고
    • Using a wrist-worn device based on peripheral tonometry to diagnose obstructive sleep apnea: In-laboratory and ambulatory validation
    • Pittman SD, Ayas NT, MacDonald MM, Malhotra A, Fogel RB, White DP. Using a wrist-worn device based on peripheral tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation. Sleep 2004;27:923-33.
    • (2004) Sleep , vol.27 , pp. 923-933
    • Pittman, S.D.1    Ayas, N.T.2    MacDonald, M.M.3    Malhotra, A.4    Fogel, R.B.5    White, D.P.6
  • 21
    • 0037338565 scopus 로고    scopus 로고
    • Evaluation of a portable device based on peripheral arterial tone for unattended home sleep studies
    • Bar A, Pillar G, Dvir I, Sheffy J, Schnall RP, Lavie P. Evaluation of a portable device based on peripheral arterial tone for unattended home sleep studies. Chest 2003;123:695-703.
    • (2003) Chest , vol.123 , pp. 695-703
    • Bar, A.1    Pillar, G.2    Dvir, I.3    Sheffy, J.4    Schnall, R.P.5    Lavie, P.6
  • 22
    • 0141446369 scopus 로고    scopus 로고
    • Assessment of a wrist-worn device in the detection of obstructive sleep apnea
    • Ayas NT, Pittman S, MacDonald M, White DP. Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Sleep Med 2003; 4:435-42.
    • (2003) Sleep Med , vol.4 , pp. 435-442
    • Ayas, N.T.1    Pittman, S.2    MacDonald, M.3    White, D.P.4
  • 23
    • 11144288656 scopus 로고    scopus 로고
    • A novel adaptive wrist actigraphy algorithm for sleep-wake assessment in sleep apnea patients
    • Hedner J, Pillar G, Pittman SD, Zou D, Grote L, White DP. A novel adaptive wrist actigraphy algorithm for sleep-wake assessment in sleep apnea patients. Sleep 2004;27:1560-6.
    • (2004) Sleep , vol.27 , pp. 1560-1566
    • Hedner, J.1    Pillar, G.2    Pittman, S.D.3    Zou, D.4    Grote, L.5    White, D.P.6
  • 24
    • 4344614073 scopus 로고    scopus 로고
    • Peripheral tonometry and actigraphy for ambulatory recording of sleep apnea
    • Penzel T, Kesper K, Pinnow I, Becker HF, Vogelmeier C. Peripheral tonometry and actigraphy for ambulatory recording of sleep apnea. Physiol Meas 2004:25:1025-36.
    • (2004) Physiol Meas , vol.25 , pp. 1025-1036
    • Penzel, T.1    Kesper, K.2    Pinnow, I.3    Becker, H.F.4    Vogelmeier, C.5
  • 25
    • 33748286726 scopus 로고    scopus 로고
    • Follow-up assessment of cpap efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry
    • Pittman SD, Pillar G, Berry R, Malhotra A, MacDonald MM, White DP. Follow-up assessment of cpap efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry. Sleep Breath 2006;10:123-31.
    • (2006) Sleep Breath , vol.10 , pp. 123-131
    • Pittman, S.D.1    Pillar, G.2    Berry, R.3    Malhotra, A.4    MacDonald, M.M.5    White, D.P.6
  • 26
    • 0030834463 scopus 로고    scopus 로고
    • An instrument to measure functional status outcomes for disorders of excessive sleepiness
    • Weaver TE, Laizner AM, Evans LK, et al. An instrument to measure functional status outcomes for disorders of excessive sleepiness. Sleep 1997;20:835-43.
    • (1997) Sleep , vol.20 , pp. 835-843
    • Weaver, T.E.1    Laizner, A.M.2    Evans, L.K.3
  • 27
    • 0037317742 scopus 로고    scopus 로고
    • Improving CPAP use by patients with the sleep apnea/hypopnea syndrome (SAHS)
    • Engleman HM, Wild MR. Improving CPAP use by patients with the sleep apnea/hypopnea syndrome (SAHS). Sleep Med Rev 2003;7:81-99.
    • (2003) Sleep Med Rev , vol.7 , pp. 81-99
    • Engleman, H.M.1    Wild, M.R.2
  • 28
    • 0028013165 scopus 로고
    • Predictive factors of long-term compliance with nasal continuous positive airway pressure treatment in the sleep apnea syndrome
    • Meurice JC, Dore P, Paquereau J, et al. Predictive factors of long-term compliance with nasal continuous positive airway pressure treatment in the sleep apnea syndrome. Chest 1994;105:429-33.
    • (1994) Chest , vol.105 , pp. 429-433
    • Meurice, J.C.1    Dore, P.2    Paquereau, J.3
  • 30
    • 34047246293 scopus 로고    scopus 로고
    • Methodology of superiority versus equivalence trials and non-inferiority trials
    • Christensen E. Methodology of superiority versus equivalence trials and non-inferiority trials. J Hepatol 2007:46:947-54.
    • (2007) J Hepatol , vol.46 , pp. 947-954
    • Christensen, E.1
  • 31
    • 0030921495 scopus 로고    scopus 로고
    • Night to night variability in CPAP use over the first three months of treatment
    • Weaver TE, Kribbs NB, Pack AI, et al. Night to night variability in CPAP use over the first three months of treatment. Sleep 1997;20:278-83.
    • (1997) Sleep , vol.20 , pp. 278-283
    • Weaver, T.E.1    Kribbs, N.B.2    Pack, A.I.3
  • 32
    • 0037346012 scopus 로고    scopus 로고
    • Nonattended home automated continuous positive airway pressure titration: Comparison with polysomnography
    • Woodson BT, Saurejan A, Brusky LT, Han JK. Nonattended home automated continuous positive airway pressure titration: comparison with polysomnography. Otolaryngol Head Neck Surg 2003:128:353-7.
    • (2003) Otolaryngol Head Neck Surg , vol.128 , pp. 353-357
    • Woodson, B.T.1    Saurejan, A.2    Brusky, L.T.3    Han, J.K.4
  • 33
    • 54349121430 scopus 로고    scopus 로고
    • Prasad B, Herdegen JJ. REM Star Pro M Series detects breathing events comparable to attended polysomnography. Am J Resp Crit Care Med 2008:A 940
    • Prasad B, Herdegen JJ. REM Star Pro M Series detects breathing events comparable to attended polysomnography. Am J Resp Crit Care Med 2008:A 940
  • 34
    • 54349086957 scopus 로고    scopus 로고
    • Validation of breathing event detection of the RemStarAuto-m series compared to clinical polysomnography
    • IkedaY, Kasai T, Takaya H, Maeno K et al. Validation of breathing event detection of the RemStarAuto-m series compared to clinical polysomnography. Am J Resp Crit Care Med 2008;177:A177
    • (2008) Am J Resp Crit Care Med , vol.177
    • Ikeda, Y.1    Kasai, T.2    Takaya, H.3    Maeno, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.