메뉴 건너뛰기




Volumn 29, Issue 9, 2008, Pages 1649-1651

MR imaging-compatible electroencephalography electrode system for an epilepsy monitoring unit

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ELECTRODE; ELECTROENCEPHALOGRAPHY; EPILEPSY; HUMAN; MAJOR CLINICAL STUDY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATIENT MONITORING; RECORDING; SEIZURE; TECHNIQUE;

EID: 54249144565     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A1143     Document Type: Article
Times cited : (7)

References (13)
  • 1
    • 0037396824 scopus 로고    scopus 로고
    • The current status of neuroimaging for epilepsy: Editorial review
    • Duncan J. The current status of neuroimaging for epilepsy: editorial review. Curr Opin Neurol 2003;16:163-64
    • (2003) Curr Opin Neurol , vol.16 , pp. 163-164
    • Duncan, J.1
  • 2
    • 0026525873 scopus 로고
    • The heating of metal electrodes during rapid-rate magnetic stimulation: A possible safety hazard
    • Roth BJ, Pascual-Leone A, Cohen LG, et al. The heating of metal electrodes during rapid-rate magnetic stimulation: a possible safety hazard. Electroencephalogr Clin Neurophysiol 1992;85:116-23
    • (1992) Electroencephalogr Clin Neurophysiol , vol.85 , pp. 116-123
    • Roth, B.J.1    Pascual-Leone, A.2    Cohen, L.G.3
  • 3
    • 0023753939 scopus 로고
    • MR imaging with topographic EEG electrodes in place
    • Lufkin R, Jordan S, Lylyck P, et al. MR imaging with topographic EEG electrodes in place. AJNR Am J Neuroradiol 1988;9:953-54
    • (1988) AJNR Am J Neuroradiol , vol.9 , pp. 953-954
    • Lufkin, R.1    Jordan, S.2    Lylyck, P.3
  • 5
    • 0011081422 scopus 로고    scopus 로고
    • Methodological issues in EEG-correlated functional MRI experiments
    • Lemieux L, Allen PJ, Krakow K, et al. Methodological issues in EEG-correlated functional MRI experiments. Int J Bioelectromagnetism 1999;1:87-95
    • (1999) Int J Bioelectromagnetism , vol.1 , pp. 87-95
    • Lemieux, L.1    Allen, P.J.2    Krakow, K.3
  • 6
    • 3843142809 scopus 로고    scopus 로고
    • MRI compatible EEG electrode system for routine use in the epilepsy monitoring unit and intensive care unit
    • Mirsattari SM, Lee DH, Jones D, et al. MRI compatible EEG electrode system for routine use in the epilepsy monitoring unit and intensive care unit. Clin Neurophysiol 2004;115:2175-80
    • (2004) Clin Neurophysiol , vol.115 , pp. 2175-2180
    • Mirsattari, S.M.1    Lee, D.H.2    Jones, D.3
  • 7
    • 0035109061 scopus 로고    scopus 로고
    • Scalp electrode impedance, infection risk, and EEG data quality
    • Ferree TC, Luu P, Russell GS, et al. Scalp electrode impedance, infection risk, and EEG data quality. Clin Neurophysiol 2001;112:536-44
    • (2001) Clin Neurophysiol , vol.112 , pp. 536-544
    • Ferree, T.C.1    Luu, P.2    Russell, G.S.3
  • 8
    • 54249091499 scopus 로고    scopus 로고
    • Automated fusion technique for fusion of MRI and CT for visualization of subdural electrodes
    • Steven D, Parrent A, Wiebe S, et al. Automated fusion technique for fusion of MRI and CT for visualization of subdural electrodes. Can J Neurol Sci 2005;32(suppl 1):S75
    • (2005) Can J Neurol Sci , vol.32 , Issue.SUPPL. 1
    • Steven, D.1    Parrent, A.2    Wiebe, S.3
  • 9
    • 0000147667 scopus 로고
    • The ten-twenty electrode system of the International Federation
    • Jasper HH. The ten-twenty electrode system of the International Federation. Electroencephalogr Clin Neurophysiol 1958;10:371-75
    • (1958) Electroencephalogr Clin Neurophysiol , vol.10 , pp. 371-375
    • Jasper, H.H.1
  • 10
    • 0038454667 scopus 로고    scopus 로고
    • Transient lesion in the splenium of the corpus callosum in an epileptic patient
    • Mirsattari SM, Lee DH, Jones MW, et al. Transient lesion in the splenium of the corpus callosum in an epileptic patient. Neurology 2003;60:1838-41
    • (2003) Neurology , vol.60 , pp. 1838-1841
    • Mirsattari, S.M.1    Lee, D.H.2    Jones, M.W.3
  • 11
    • 33646100290 scopus 로고    scopus 로고
    • Transient and permanent magnetic resonance imaging abnormalities after complex partial status epilepticus
    • Bauer G, Gotwald T, Dobesberger J, et al. Transient and permanent magnetic resonance imaging abnormalities after complex partial status epilepticus. Epilepsy Behav 2006;8:666-71
    • (2006) Epilepsy Behav , vol.8 , pp. 666-671
    • Bauer, G.1    Gotwald, T.2    Dobesberger, J.3
  • 12
    • 34548008817 scopus 로고    scopus 로고
    • Irreversible brain injury following status epilepticus
    • Korngut L, Young GB, Lee DH, et al. Irreversible brain injury following status epilepticus. Epilepsy Behav 2007;11:235-40
    • (2007) Epilepsy Behav , vol.11 , pp. 235-240
    • Korngut, L.1    Young, G.B.2    Lee, D.H.3
  • 13
    • 54249141370 scopus 로고    scopus 로고
    • Evaluation of MR compatibility for EEG electrodes
    • Stevens TK, Mirsattari SM, Ives JR, et al. Evaluation of MR compatibility for EEG electrodes. Epilepsia 2004;45(suppl 7):S304
    • (2004) Epilepsia , vol.45 , Issue.SUPPL. 7
    • Stevens, T.K.1    Mirsattari, S.M.2    Ives, J.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.