메뉴 건너뛰기




Volumn 71, Issue 4, 2008, Pages 687-693

Phonon linewidths in YNi2B2C

Author keywords

Density functional theory; Electron phonon coupling; Inelastic neutron scattering

Indexed keywords

ELECTRON CORRELATIONS; ELECTRON-PHONON INTERACTIONS; ELECTRONS; FORECASTING; INELASTIC NEUTRON SCATTERING; LINEWIDTH; TEMPERATURE DISTRIBUTION;

EID: 54249137808     PISSN: 03044289     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12043-008-0257-z     Document Type: Conference Paper
Times cited : (13)

References (10)
  • 1
    • 0001231112 scopus 로고    scopus 로고
    • The DFT calculations were carried out within the framework of the mixed basis pseudopotential method using the local density approximation. A density functional perturbation approach was used for calculating properties of the lattice dynamics and electron-phonon coupling. Details can be found in R Heid and K-P Bohnen, Phys. Rev. B60, R3709 1999
    • The DFT calculations were carried out within the framework of the mixed basis pseudopotential method using the local density approximation. A density functional perturbation approach was used for calculating properties of the lattice dynamics and electron-phonon coupling. Details can be found in R Heid and K-P Bohnen, Phys. Rev. B60, R3709 (1999)
  • 3
  • 6
    • 54249168460 scopus 로고    scopus 로고
    • For the Gaussian smearing used in our calculations, a smearing by 1 meV corresponds approximately to a temperature of 5.5 K
    • For the Gaussian smearing used in our calculations, a smearing by 1 meV corresponds approximately to a temperature of 5.5 K
  • 7
    • 54249130776 scopus 로고    scopus 로고
    • The calculations required about three months of computer time for each value of the smearing parameter, using a very fast work station. Reducing the smearing parameter to 10 meV would require usage of a much denser mesh in q-space and hence an order of magnitude longer computer time
    • The calculations required about three months of computer time for each value of the smearing parameter, using a very fast work station. Reducing the smearing parameter to 10 meV would require usage of a much denser mesh in q-space and hence an order of magnitude longer computer time
  • 9
    • 54249127883 scopus 로고    scopus 로고
    • We note that many calculations published in the literature were done with ΔE, 200 meV, i.e. the largest value used in our study
    • We note that many calculations published in the literature were done with ΔE = 200 meV, i.e. the largest value used in our study
  • 10
    • 16344388408 scopus 로고    scopus 로고
    • A better approximation was recently proposed by M Calandra, and F Mauri, Phys. Rev. B71, 064501 (2005), which needs, however, a very large computational effort
    • A better approximation was recently proposed by M Calandra, and F Mauri, Phys. Rev. B71, 064501 (2005), which needs, however, a very large computational effort


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.