메뉴 건너뛰기




Volumn 29, Issue 3, 2008, Pages 265-267

The concept of forensic emergency medicine as illustrated by an unusual complication of pulmonary artery catheterization

Author keywords

Forensic emergency medicine; Pulmonary artery catheter; Seldinger; Swan Ganz

Indexed keywords

AGED; ANAMNESIS; ANESTHESIA COMPLICATION; ARTERY CATHETERIZATION; ARTERY PERFORATION; ARTICLE; ARTIFICIAL VENTILATION; AUTOPSY; BRAIN EDEMA; CARDIOVASCULAR SYSTEM; CAROTID ARTERY; CASE REPORT; CATHETER COMPLICATION; CAUSE OF DEATH; CERVICAL SPINE; COMPUTER ASSISTED TOMOGRAPHY; DEATH; EMERGENCY MEDICINE; FORENSIC MEDICINE; FORENSIC PATHOLOGY; HEAD INJURY; HEMODYNAMICS; HOSPITAL ADMISSION; HUMAN; INTENSIVE CARE UNIT; INTRACRANIAL PRESSURE; MALE; MEAN ARTERIAL PRESSURE; MEDICAL INSTRUMENTATION; MEDICOLEGAL ASPECT; OCCIPITAL LOBE; PULMONARY ARTERY CATHETER; SUBCLAVIAN VEIN; SUBDURAL HEMATOMA; SWAN GANZ CATHETER; BRAIN CIRCULATION; BRAIN ISCHEMIA; CAROTID ARTERY INJURY; INJURY; PATHOLOGY;

EID: 54049151250     PISSN: 01957910     EISSN: None     Source Type: Journal    
DOI: 10.1097/PAF.0b013e318183455a     Document Type: Article
Times cited : (3)

References (16)
  • 1
    • 0014964972 scopus 로고
    • Catheterisation of the heart in man with use of a flow-directed balloon-tipped catheter
    • Swan HJ, Ganz W, Forrester J, et al. Catheterisation of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283:447-451.
    • (1970) N Engl J Med , vol.283 , pp. 447-451
    • Swan, H.J.1    Ganz, W.2    Forrester, J.3
  • 2
    • 0021907263 scopus 로고
    • Pulmonary artery perforations as typical complication in the use of Swan-Ganz catheters
    • Lieske K, Puschel K, Doehn M. Pulmonary artery perforations as typical complication in the use of Swan-Ganz catheters. Z Rechtsmed. 1985;94: 51-60.
    • (1985) Z Rechtsmed , vol.94 , pp. 51-60
    • Lieske, K.1    Puschel, K.2    Doehn, M.3
  • 3
    • 0029828432 scopus 로고    scopus 로고
    • Cardiac arrest during removal of a pulmonary artery catheter
    • Nakayama M, Aimono M, Kawana S, et al. Cardiac arrest during removal of a pulmonary artery catheter. Can J Anaesth. 1996;43:972-974.
    • (1996) Can J Anaesth , vol.43 , pp. 972-974
    • Nakayama, M.1    Aimono, M.2    Kawana, S.3
  • 4
    • 0036715711 scopus 로고    scopus 로고
    • Complications of invasive monitoring
    • Bowdle TA. Complications of invasive monitoring. Anesthesiol Clin North America. 2002;20:571-588.
    • (2002) Anesthesiol Clin North America , vol.20 , pp. 571-588
    • Bowdle, T.A.1
  • 5
    • 33646264553 scopus 로고    scopus 로고
    • Swan-Ganz catheter-induced severe complications in cardiac surgery: Right ventricular perforation, knotting, and rupture of a pulmonary artery
    • Bossert T, Gummert JF, Bittner HB, et al. Swan-Ganz catheter-induced severe complications in cardiac surgery: right ventricular perforation, knotting, and rupture of a pulmonary artery. J Card Surg. 2006;21:292-295.
    • (2006) J Card Surg , vol.21 , pp. 292-295
    • Bossert, T.1    Gummert, J.F.2    Bittner, H.B.3
  • 6
    • 0035143831 scopus 로고    scopus 로고
    • Central line mechanical complication rate in emergency medicine patients
    • Steele R, Irvin CB. Central line mechanical complication rate in emergency medicine patients. Acad Emerg Med. 2001;8:204-207.
    • (2001) Acad Emerg Med , vol.8 , pp. 204-207
    • Steele, R.1    Irvin, C.B.2
  • 8
    • 2942564583 scopus 로고    scopus 로고
    • Emergency physician-verified out-of-hospital intubation: Miss rates by paramedics
    • Jones JH, Murphy MP, Dickson RL, et al. Emergency physician-verified out-of-hospital intubation: miss rates by paramedics. Acad Emerg Med. 2004;11:707-709.
    • (2004) Acad Emerg Med , vol.11 , pp. 707-709
    • Jones, J.H.1    Murphy, M.P.2    Dickson, R.L.3
  • 9
    • 0031896381 scopus 로고    scopus 로고
    • Airway management in the emergency department: A one-year study of 610 tracheal intubations
    • Sakles JC, Laurin EG, Rantapaa AA, et al. Airway management in the emergency department: a one-year study of 610 tracheal intubations. Ann Emerg Med. 1998;31:398-400.
    • (1998) Ann Emerg Med , vol.31 , pp. 398-400
    • Sakles, J.C.1    Laurin, E.G.2    Rantapaa, A.A.3
  • 10
    • 0024442828 scopus 로고
    • Trauma and forensic medicine
    • Carmona R, Prince K. Trauma and forensic medicine. J Trauma. 1989;29:1222-1225.
    • (1989) J Trauma , vol.29 , pp. 1222-1225
    • Carmona, R.1    Prince, K.2
  • 11
    • 0027402267 scopus 로고
    • Clinicians' forensic interpretations of fatal gunshot wounds often miss the mark
    • Randall T. Clinicians' forensic interpretations of fatal gunshot wounds often miss the mark. JAMA. 1993;69:2058, 2061.
    • (1993) JAMA , vol.69 , Issue.2058 , pp. 2061
    • Randall, T.1
  • 12
    • 0028673498 scopus 로고
    • Interpretation of fatal, multiple, and exiting gunshot wounds by trauma specialists
    • Collins KA, Lantz PE. Interpretation of fatal, multiple, and exiting gunshot wounds by trauma specialists. J Forensic Sci. 1994;39:94-99.
    • (1994) J Forensic Sci , vol.39 , pp. 94-99
    • Collins, K.A.1    Lantz, P.E.2
  • 13
    • 1542285381 scopus 로고    scopus 로고
    • A survey of the involvement of accident and emergency doctors in medicolegal work in Hong Kong
    • Wong TW, Beh P, Lau CC, Tung WK. A survey of the involvement of accident and emergency doctors in medicolegal work in Hong Kong. J Clin Forensic Med. 2004;11:75-77.
    • (2004) J Clin Forensic Med , vol.11 , pp. 75-77
    • Wong, T.W.1    Beh, P.2    Lau, C.C.3    Tung, W.K.4
  • 14
    • 0037152938 scopus 로고    scopus 로고
    • Death and paramethoxyamphetamine - an evolving problem
    • Jacobs W. Death and paramethoxyamphetamine - an evolving problem. Med J Aust. 2002;177:460.
    • (2002) Med J Aust , vol.177 , pp. 460
    • Jacobs, W.1
  • 15
    • 33748486897 scopus 로고    scopus 로고
    • Fatal amphetamine-associated cardiotoxicity and its medico-legal implications
    • Jacobs W. Fatal amphetamine-associated cardiotoxicity and its medico-legal implications. Am J Forensic Med Pathol. 2006;27:156-160.
    • (2006) Am J Forensic Med Pathol , vol.27 , pp. 156-160
    • Jacobs, W.1
  • 16
    • 2442713397 scopus 로고
    • Catheter replacement of the needle in percutaneous arte-riography; a new technique
    • Seldinger SI. Catheter replacement of the needle in percutaneous arte-riography; a new technique. Acta Radiol. 1953;39:368-376.
    • (1953) Acta Radiol , vol.39 , pp. 368-376
    • Seldinger, S.I.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.