메뉴 건너뛰기




Volumn 23, Issue 4, 2008, Pages 2401-2408

Earth return impedances of conductor arrangements in multilayer soils - Part II: Numerical results

Author keywords

Electromagnetic transient analysis; Finite element method (FEM); Nonhomogeneous earth; Power cables; Transmission line modeling

Indexed keywords

CABLES; ELECTRIC LINES; FINITE ELEMENT METHOD; MULTILAYERS; POWER TRANSMISSION; TELECOMMUNICATION CABLES;

EID: 54049136412     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2008.923999     Document Type: Article
Times cited : (16)

References (14)
  • 1
    • 54049109193 scopus 로고    scopus 로고
    • Earth return impedances of conductor arrangements in multi-layer soils - Part I: Theoretical model
    • D. A. Tsiamitros, G. K. Papagiannis, and P. S. Dokopoulos, "Earth return impedances of conductor arrangements in multi-layer soils - Part I: Theoretical model," IEEE Trans. Power Del., vol. 23, no. 4, pp. 2392-2400, 2008.
    • (2008) IEEE Trans. Power Del , vol.23 , Issue.4 , pp. 2392-2400
    • Tsiamitros, D.A.1    Papagiannis, G.K.2    Dokopoulos, P.S.3
  • 2
    • 27844573418 scopus 로고    scopus 로고
    • A systematic approach to the evaluation of the influence of multi-layered earth on overhead power transmission lines
    • Oct
    • G. K. Papagiannis, D. A. Tsiamitros, D. P. Labridis, and P. S. Dokopoulos, "A systematic approach to the evaluation of the influence of multi-layered earth on overhead power transmission lines," IEEE Trans. Power Del., vol. 20, no. 4, pp. 2594-2601, Oct. 2005.
    • (2005) IEEE Trans. Power Del , vol.20 , Issue.4 , pp. 2594-2601
    • Papagiannis, G.K.1    Tsiamitros, D.A.2    Labridis, D.P.3    Dokopoulos, P.S.4
  • 3
    • 23944505738 scopus 로고    scopus 로고
    • D. A. Tsiamitros, G. K. Papagiannis, D. P. Labridis, and P. S. Dokopoulos, Earth return path impedances of underground cables for the two-layer case, IEEE Trans. Power Del., 20, no. 3, pp. 2174-2181, Jul. 2005.
    • D. A. Tsiamitros, G. K. Papagiannis, D. P. Labridis, and P. S. Dokopoulos, "Earth return path impedances of underground cables for the two-layer case," IEEE Trans. Power Del., vol. 20, no. 3, pp. 2174-2181, Jul. 2005.
  • 5
    • 0027678175 scopus 로고
    • A Comparison among different techni ques to achieve an optimum estimation of electrical grounding parameters in two-layered earth
    • Oct
    • J. L. del Alamo, "A Comparison among different techni ques to achieve an optimum estimation of electrical grounding parameters in two-layered earth," IEEE Trans. Power Del., vol. 8, no. 4, pp. 1890-1899, Oct. 1993.
    • (1993) IEEE Trans. Power Del , vol.8 , Issue.4 , pp. 1890-1899
    • del Alamo, J.L.1
  • 6
    • 0030196522 scopus 로고    scopus 로고
    • Interpretation of resistivity sounding measurements in N-layer soil using electrostatic images
    • Jul
    • P. J. Lagace, J. Fortin, and E. D. Crainic, "Interpretation of resistivity sounding measurements in N-layer soil using electrostatic images," IEEE Trans. Power Del., vol. 11, no. 3, pp. 1349-1354, Jul. 1996.
    • (1996) IEEE Trans. Power Del , vol.11 , Issue.3 , pp. 1349-1354
    • Lagace, P.J.1    Fortin, J.2    Crainic, E.D.3
  • 7
    • 0016936802 scopus 로고
    • Earth return impedance for the multilayer case
    • Mar
    • M. Nakagawa and K. Iwamoto, "Earth return impedance for the multilayer case," IEEE Trans. Power App. Syst., vol. PAS-95, no. 2, pt. 1, pp. 671-676, Mar. 1976.
    • (1976) IEEE Trans. Power App. Syst , vol.PAS-95 , Issue.2 PART. 1 , pp. 671-676
    • Nakagawa, M.1    Iwamoto, K.2
  • 8
    • 0033876027 scopus 로고    scopus 로고
    • Comparative presentation of criteria used for adaptive finite element mesh generation in multiconductor eddy current problems
    • Jan
    • D. P. Labridis, "Comparative presentation of criteria used for adaptive finite element mesh generation in multiconductor eddy current problems," IEEE Trans. Magn., vol. 36, no. 1, pt. 2, pp. 267-280, Jan. 2000.
    • (2000) IEEE Trans. Magn , vol.36 , Issue.1 PART. 2 , pp. 267-280
    • Labridis, D.P.1
  • 9
    • 0034138375 scopus 로고    scopus 로고
    • A one-step finite element formulation for the modelling of single and double circuit transmission lines
    • Jan
    • G. K. Papagiannis, D. G. Triantafyllidis, and D. P. Labridis, "A one-step finite element formulation for the modelling of single and double circuit transmission lines," IEEE Trans. Power Syst., vol. 15, no. 1, pp. 33-38, Jan. 2000.
    • (2000) IEEE Trans. Power Syst , vol.15 , Issue.1 , pp. 33-38
    • Papagiannis, G.K.1    Triantafyllidis, D.G.2    Labridis, D.P.3
  • 12
    • 0016108615 scopus 로고
    • Numerical modeling of frequency-dependent transmission line parameters in an electromagnetic transients program
    • Sep
    • W. S. Meyer and H. W. Dommel, "Numerical modeling of frequency-dependent transmission line parameters in an electromagnetic transients program," IEEE Trans. Power App. Syst., vol. PAS-93, no. 5, pp. 1401-1409, Sep. 1974.
    • (1974) IEEE Trans. Power App. Syst , vol.PAS-93 , Issue.5 , pp. 1401-1409
    • Meyer, W.S.1    Dommel, H.W.2
  • 13
    • 54049111958 scopus 로고    scopus 로고
    • Electromagnetic Transients Program Reference Manual, Bonneville Power Administration, 1986, pp. 5-15-15-22.
    • "Electromagnetic Transients Program Reference Manual," Bonneville Power Administration, 1986, pp. 5-15-15-22.
  • 14
    • 0037247318 scopus 로고    scopus 로고
    • A robust phase-coordinates frequency-dependent underground cable model (zCable) for the EMTP
    • Jan
    • T.-C. Yu and J. R. Marti, "A robust phase-coordinates frequency-dependent underground cable model (zCable) for the EMTP," IEEE Trans. Power Del., vol. 18, no. 1, pp. 189-194, Jan. 2003.
    • (2003) IEEE Trans. Power Del , vol.18 , Issue.1 , pp. 189-194
    • Yu, T.-C.1    Marti, J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.