-
1
-
-
0027535075
-
Pitfalls in echocardiographic diagnosis of intracardiac and extracardiac masses
-
10.1111/j.1540-8175.1993.tb00029.x 10171636
-
Alam M Pitfalls in echocardiographic diagnosis of intracardiac and extracardiac masses Echocardiography 1993, 10:181-90. 10.1111/ j.1540-8175.1993.tb00029.x 10171636
-
(1993)
Echocardiography
, vol.10
, pp. 181-190
-
-
Alam, M.1
-
2
-
-
18744411261
-
A right atrial mass and a pseudomass
-
10.1111/j.1540-8175.2005.04049.x 15901299
-
Chen MS Sun JP Asher CR A right atrial mass and a pseudomass Echocardiography 2005, 22:441-444. 10.1111/j.1540-8175.2005.04049.x 15901299
-
(2005)
Echocardiography
, vol.22
, pp. 441-444
-
-
Chen, M.S.1
Sun, J.P.2
Asher, C.R.3
-
3
-
-
0035180579
-
Caseous calcification of the mitral annulus: A neglected, unrecognized diagnosis
-
10.1067/mje.2001.111877 11490332
-
Harpaz D Auerbach I Vered Z Motro M Tobar A Rosenblatt S Caseous calcification of the mitral annulus: A neglected, unrecognized diagnosis J Am Soc Echocardiogr 2001, 14:825-831. 10.1067/mje.2001.111877 11490332
-
(2001)
J Am Soc Echocardiogr
, vol.14
, pp. 825-831
-
-
Harpaz, D.1
Auerbach, I.2
Vered, Z.3
Motro, M.4
Tobar, A.5
Rosenblatt, S.6
-
4
-
-
33645510296
-
Diagnostic dilemma: A pacemaker lead inside the left atrium or an echocardiographic beam width artifact?
-
10.1213/01.ane.0000198336.46894.58 16551895
-
Skubas N Brown NI Mishra R Diagnostic dilemma: A pacemaker lead inside the left atrium or an echocardiographic beam width artifact? Anesth Analg 2006, 102:1043-1044. 10.1213/01.ane.0000198336.46894.58 16551895
-
(2006)
Anesth Analg
, vol.102
, pp. 1043-1044
-
-
Skubas, N.1
Brown, N.I.2
Mishra, R.3
-
5
-
-
33947123597
-
Interference of breast implants with echocardiographic image acquisition and interpretation
-
10.1186/1476-7120-5-9
-
Movahed MR Interference of breast implants with echocardiographic image acquisition and interpretation Cardiovasc Ultrasound 2007, 23:9. 10.1186/ 1476-7120-5-9
-
(2007)
Cardiovasc Ultrasound
, vol.23
, pp. 9
-
-
Movahed, M.R.1
-
6
-
-
0344240114
-
Usefulness of motion patterns indentified by tissue Doppler echocardiography for diagnosing various cardiac masses, particularly valvular vegetations
-
10.1016/S0002-9149(99)00590-1 10606117
-
Bartel T Müller S Nesser HJ Möhlenkamp S Bruch C Erbel R Usefulness of motion patterns indentified by tissue Doppler echocardiography for diagnosing various cardiac masses, particularly valvular vegetations Am J Cardiol 1999, 84:1428-1433. 10.1016/ S0002-9149(99)00590-1 10606117
-
(1999)
Am J Cardiol
, vol.84
, pp. 1428-1433
-
-
Bartel, T.1
Müller, S.2
Nesser, H.J.3
Möhlenkamp, S.4
Bruch, C.5
Erbel, R.6
-
7
-
-
0032911266
-
Mobile echoes on prosthetic valves are not reproducible. Results and clinical implications of a multicentre study
-
10.1053/euhj.1998.1151 10099911
-
Ionescu AA Moreno de la Santa P Dunstan FD Butchart EG Fraser AG Mobile echoes on prosthetic valves are not reproducible. Results and clinical implications of a multicentre study Eur Heart J 1999, 20:140-147. 10.1053/euhj.1998.1151 10099911
-
(1999)
Eur Heart J
, vol.20
, pp. 140-147
-
-
Ionescu, A.A.1
Moreno de la Santa, P.2
Dunstan, F.D.3
Butchart, E.G.4
Fraser, A.G.5
-
8
-
-
0034886361
-
Differential transesophageal echocardiographic diagnosis between linear artifacts and intraluminal flap of aortic dissection or disruption
-
10.1378/chest.119.6.1778 11399705
-
Vignon P Spencer KT Rambaud G Preux PM Krauss D Balasia B Lang RM Differential transesophageal echocardiographic diagnosis between linear artifacts and intraluminal flap of aortic dissection or disruption Chest 2001, 119:1778-1790. 10.1378/chest.119.6.1778 11399705
-
(2001)
Chest
, vol.119
, pp. 1778-1790
-
-
Vignon, P.1
Spencer, K.T.2
Rambaud, G.3
Preux, P.M.4
Krauss, D.5
Balasia, B.6
Lang, R.M.7
-
9
-
-
2142748493
-
Usefulness of multiplane transesophageal echocardiography in the recognition of artifacts and normal anatomical variants that may mimic left atrial thrombi in patients with atrial fibrillation
-
14699710
-
Maltagliati A Pepi M Tamborini G Muratori M Celeste F Doria E Galli C Usefulness of multiplane transesophageal echocardiography in the recognition of artifacts and normal anatomical variants that may mimic left atrial thrombi in patients with atrial fibrillation Ital Heart J 2003, 4:797-802. 14699710
-
(2003)
Ital Heart J
, vol.4
, pp. 797-802
-
-
Maltagliati, A.1
Pepi, M.2
Tamborini, G.3
Muratori, M.4
Celeste, F.5
Doria, E.6
Galli, C.7
-
10
-
-
33845975680
-
Diagnosis of left atrial appendage thrombi by multiplane transesophageal echocardiography: Interlaboratory comparative study
-
10.1253/circj.71.122 17186989
-
Schneider B Stöllberger C Schneider B Diagnosis of left atrial appendage thrombi by multiplane transesophageal echocardiography: interlaboratory comparative study Circ J 2007, 71:122-125. 10.1253/ circj.71.122 17186989
-
(2007)
Circ J
, vol.71
, pp. 122-125
-
-
Schneider, B.1
Stöllberger, C.2
Schneider, B.3
-
11
-
-
0027078558
-
Transesophageal echocardiographic artifact mimicking an aortic valve tumor
-
10.1016/1053-0770(92)90060-K 1472672
-
Neustein SM Narang J Transesophageal echocardiographic artifact mimicking an aortic valve tumor J Cardiothorac Vasc Anesth 1992, 6:724-727. 10.1016/1053-0770(92)90060-K 1472672
-
(1992)
J Cardiothorac Vasc Anesth
, vol.6
, pp. 724-727
-
-
Neustein, S.M.1
Narang, J.2
-
12
-
-
0020700263
-
In vivo ultrasonic tissue characterization of human intracardiac masses
-
10.1016/S0002-9149(83)80041-1 6849262
-
Green SE Joynt LF Fitzgerald PJ Rubenson DS Popp RL In vivo ultrasonic tissue characterization of human intracardiac masses Am J Cardiol 1983, 51:231-236. 10.1016/S0002-9149(83)80041-1 6849262
-
(1983)
Am J Cardiol
, vol.51
, pp. 231-236
-
-
Green, S.E.1
Joynt, L.F.2
Fitzgerald, P.J.3
Rubenson, D.S.4
Popp, R.L.5
-
13
-
-
0037332041
-
Chest ultrasound for 'Dummies'
-
10.1378/chest.123.2.332 12576345
-
Doelken P Strange C Chest ultrasound for 'Dummies' Chest 2003, 123:332-333. 10.1378/chest.123.2.332 12576345
-
(2003)
Chest
, vol.123
, pp. 332-333
-
-
Doelken, P.1
Strange, C.2
-
16
-
-
34248213054
-
Clinical review: Bedside lung ultrasound in critical care practice
-
2151891 17316468 10.1186/cc5668
-
Bouhemad B Zhang M Lu Q Rouby JJ Clinical review: Bedside lung ultrasound in critical care practice Crit Care 2007, 11:205. 2151891 17316468 10.1186/cc5668
-
(2007)
Crit Care
, vol.11
, pp. 205
-
-
Bouhemad, B.1
Zhang, M.2
Lu, Q.3
Rouby, J.J.4
-
17
-
-
1342310781
-
Ultrasound diagnosis of alveolar consolidation in the critically ill
-
10.1007/s00134-003-2075-6 14722643
-
Lichtenstein DA Lascols N Meziere G Gepner A Ultrasound diagnosis of alveolar consolidation in the critically ill Intensive Care Med 2004, 30:276-281. 10.1007/s00134-003-2075-6 14722643
-
(2004)
Intensive Care Med
, vol.30
, pp. 276-281
-
-
Lichtenstein, D.A.1
Lascols, N.2
Meziere, G.3
Gepner, A.4
-
18
-
-
33747423142
-
Pleural effusion and introduction to the lung ultrasound technique
-
Berlin: Springer-Verlag Lichtenstein D
-
Lichtenstein D Pleural effusion and introduction to the lung ultrasound technique General Ultrasound in the Critically Ill Berlin: Springer-Verlag Lichtenstein D 2005, 96-100.
-
(2005)
General Ultrasound in the Critically Ill
, pp. 96-100
-
-
Lichtenstein, D.1
-
20
-
-
0014082844
-
Reflected ultrasound in the detection and localization of pleural effusion
-
10.1001/jama.200.5.399 6071511
-
Joyner CR Jr Herman RJ Reid JM Reflected ultrasound in the detection and localization of pleural effusion JAMA 1967, 200:399-402. 10.1001/ jama.200.5.399 6071511
-
(1967)
JAMA
, vol.200
, pp. 399-402
-
-
Joyner Jr., C.R.1
Herman, R.J.2
Reid, J.M.3
-
21
-
-
0026684466
-
Ultrasound guided percutaneous cutting biopsy for the diagnosis of pulmonary consolidations of unknown aetiology
-
463812 1496506
-
Yang PC Chang DB Yu CJ Lee YC Kuo SH Luh KT Ultrasound guided percutaneous cutting biopsy for the diagnosis of pulmonary consolidations of unknown aetiology Thorax 1992, 47:457-460. 463812 1496506
-
(1992)
Thorax
, vol.47
, pp. 457-460
-
-
Yang, P.C.1
Chang, D.B.2
Yu, C.J.3
Lee, Y.C.4
Kuo, S.H.5
Luh, K.T.6
-
23
-
-
0032822462
-
Feasibility and safety of ultrasound-aided thoracentesis in mechanically ventilated patients
-
10.1007/s001340050988 10501751
-
Lichtenstein D Hulot JS Rabiller A Tostivint I Meziere G Feasibility and safety of ultrasound-aided thoracentesis in mechanically ventilated patients Intensive Care Med 1999, 25:955-958. 10.1007/s001340050988 10501751
-
(1999)
Intensive Care Med
, vol.25
, pp. 955-958
-
-
Lichtenstein, D.1
Hulot, J.S.2
Rabiller, A.3
Tostivint, I.4
Meziere, G.5
-
24
-
-
0024723470
-
Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms
-
2698218
-
Schiller NB Shah PM Crawford M DeMaria A Devereux R Feigenbaum H Gutgesell H Reichek N Sahn D Schnittger I Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms J Am Soc Echocardiogr 1989, 2:358-267. 2698218
-
(1989)
J Am Soc Echocardiogr
, vol.2
, pp. 267-358
-
-
Schiller, N.B.1
Shah, P.M.2
Crawford, M.3
DeMaria, A.4
Devereux, R.5
Feigenbaum, H.6
Gutgesell, H.7
Reichek, N.8
Sahn, D.9
Schnittger, I.10
-
25
-
-
0032963363
-
Determinants of aortic artifacts during transesophageal echocardiography in the ascending aorta
-
10.1016/S0002-8703(99)70423-0 10220648
-
Losi MA Betocchi S Briguori C Manganelli F Ciampi Q Pace L Iannelli G Spampinato N Chiariello M Determinants of aortic artifacts during transesophageal echocardiography in the ascending aorta Am Heart J 1999, 137:967-972. 10.1016/S0002-8703(99)70423-0 10220648
-
(1999)
Am Heart J
, vol.137
, pp. 967-972
-
-
Losi, M.A.1
Betocchi, S.2
Briguori, C.3
Manganelli, F.4
Ciampi, Q.5
Pace, L.6
Iannelli, G.7
Spampinato, N.8
Chiariello, M.9
-
27
-
-
30344452549
-
Physics and instrumentation
-
Philadelphia, PA: Lippincott Williams and Wilkins Feigenbaum H, Armrstrong WF, Ryan T
-
Feigenbaum H Physics and instrumentation Feigenbaums's Echocardiography Philadelphia, PA: Lippincott Williams and Wilkins Feigenbaum H, Armrstrong WF, Ryan T 2005, 29-32.
-
(2005)
Feigenbaums's Echocardiography
, pp. 29-32
-
-
Feigenbaum, H.1
-
29
-
-
0020537557
-
Commonly encountered artifacts in clinical ultrasound
-
Laing FC Commonly encountered artifacts in clinical ultrasound Semin Ultrasound 1983, 4:27-43.
-
(1983)
Semin Ultrasound
, vol.4
, pp. 27-43
-
-
Laing, F.C.1
-
32
-
-
4444313942
-
Handheld thoracic sonography for detecting post-traumatic pneumothoraces: The Extended Focused Assessment with Sonography for Trauma (EFAST)
-
15345974
-
Kirkpatrick AW Sirois M Laupland KB Liu D Rowan K Ball CG Hameed SM Brown R Simons R Dulchavsky SA Hamiilton DR Nicolaou S Handheld thoracic sonography for detecting post-traumatic pneumothoraces: The Extended Focused Assessment with Sonography for Trauma (EFAST) J Trauma 2004, 57:288-295. 15345974
-
(2004)
J Trauma
, vol.57
, pp. 288-295
-
-
Kirkpatrick, A.W.1
Sirois, M.2
Laupland, K.B.3
Liu, D.4
Rowan, K.5
Ball, C.G.6
Hameed, S.M.7
Brown, R.8
Simons, R.9
Dulchavsky, S.A.10
Hamiilton, D.R.11
Nicolaou, S.12
|