메뉴 건너뛰기




Volumn , Issue , 2008, Pages

A Fibre Bragg grating manometry catheter for in-vivo diagnostics of swallowing disorders

Author keywords

[No Author keywords available]

Indexed keywords

CATHETERS; FIBER BRAGG GRATINGS; OPTICAL FIBERS; OPTICAL MATERIALS;

EID: 54049091914     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/OECCACOFT.2008.4610536     Document Type: Conference Paper
Times cited : (5)

References (8)
  • 1
    • 54049150650 scopus 로고    scopus 로고
    • http://www.vitalstim.com/pdf/Dysphagia%20Fact%20Sheet%20(4599A).pdf
    • http://www.vitalstim.com/pdf/Dysphagia%20Fact%20Sheet%20(4599A).pdf
  • 2
    • 54049100218 scopus 로고    scopus 로고
    • http://www.ahrq.gov/cl inic/epcsums/dysphsum.htm
  • 4
    • 0033082182 scopus 로고    scopus 로고
    • Multiple Intraluminal Electrical Impedancometry for Recording of Upper GI Motility
    • Nguyen H. N., Silny J., Matern S., "Multiple Intraluminal Electrical Impedancometry for Recording of Upper GI Motility", The American Journal of Gas troenterology; Volume 94; Number 2; 1999
    • (1999) The American Journal of Gas troenterology , vol.94 , Issue.2
    • Nguyen, H.N.1    Silny, J.2    Matern, S.3
  • 5
    • 0034791527 scopus 로고    scopus 로고
    • Nicosia, M.A., Brasseur, J.G., Liu, J -L., Miller, L.S. 2001 Longitudina l shortening in the human esophagus from high -frequency ultrasonography. Amer. J. Physiol. 281 (Gastrointest. Liver Physiol.): G1022-G1033
    • Nicosia, M.A., Brasseur, J.G., Liu, J -L., Miller, L.S. 2001 Longitudina l shortening in the human esophagus from high -frequency ultrasonography. Amer. J. Physiol. 281 (Gastrointest. Liver Physiol.): G1022-G1033
  • 6
    • 0017070843 scopus 로고
    • A new technique for continuous sphincter pressure measurement
    • Dent J. "A new technique for continuous sphincter pressure measurement". Gastroenterology 1976; 71: 263-7.
    • (1976) Gastroenterology , vol.71 , pp. 263-267
    • Dent, J.1
  • 7
    • 8144226585 scopus 로고    scopus 로고
    • Development and clinical validation of a solid -state high-resolution pressure measurement system for simplified and consistent esophageal manometry
    • Clouse RE, Parks T, Haroian LR, Zakko SF. "Development and clinical validation of a solid -state high-resolution pressure measurement system for simplified and consistent esophageal manometry". Am J Gastroenterol, 2003;98(Suppl):S32-S33
    • (2003) Am J Gastroenterol , vol.98 , Issue.SUPPL.
    • Clouse, R.E.1    Parks, T.2    Haroian, L.R.3    Zakko, S.F.4
  • 8
    • 0018853331 scopus 로고    scopus 로고
    • Welch, R., W., et al. Normal lower esophageal sphincter pressure: A comparison of rapid vs slow pull-through techniques . Gastroenterology 1980; 78 1446-1451
    • Welch, R., W., et al. "Normal lower esophageal sphincter pressure: A comparison of rapid vs slow pull-through techniques ". Gastroenterology 1980; 78 1446-1451


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.