메뉴 건너뛰기




Volumn 18, Issue 11, 2008, Pages 2684-2690

Demonstration of the Adamkiewicz artery in patients with descending or thoracoabdominal aortic aneurysm: Optimization of contrast-medium application for 64-detector-row CT angiography

Author keywords

Adamkiewicz artery; Aortic aneurysm; Contrast media; Helical computed tomography

Indexed keywords

IOMEPROL;

EID: 54049091169     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-008-1036-4     Document Type: Article
Times cited : (31)

References (17)
  • 1
    • 0031005857 scopus 로고    scopus 로고
    • Surgery of the thoracic aorta
    • Kouchoukos NT, Dougenis D (1997) Surgery of the thoracic aorta. N Engl J Med 336:1876-1888
    • (1997) N Engl J Med , vol.336 , pp. 1876-1888
    • Kouchoukos, N.T.1    Dougenis, D.2
  • 2
    • 1842685288 scopus 로고    scopus 로고
    • Introduction of adjuncts and their influence on changing results in 402 consecutive thoracoabdominal aortic aneurysm repairs
    • Schepens M, Dossche K, Morshuis W et al (2004) Introduction of adjuncts and their influence on changing results in 402 consecutive thoracoabdominal aortic aneurysm repairs. Eur J Cardiothorac Surg 25:701-707
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 701-707
    • Schepens, M.1    Dossche, K.2    Morshuis, W.3
  • 3
    • 0031913878 scopus 로고    scopus 로고
    • Importance of intercostal artery reattachment during thoracoabdominal aortic aneurysm repair
    • discussion 66-58
    • Safi HJ, Miller CC 3rd, Carr C, Iliopoulos DC, Dorsay DA, Baldwin JC (1998) Importance of intercostal artery reattachment during thoracoabdominal aortic aneurysm repair. J Vasc Surg 27:58-66, discussion 66-58
    • (1998) J Vasc Surg , vol.27 , pp. 58-66
    • Safi, H.J.1    Miller III, C.C.2    Carr, C.3    Iliopoulos, D.C.4    Dorsay, D.A.5    Baldwin, J.C.6
  • 4
    • 0030032140 scopus 로고    scopus 로고
    • The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms
    • Grabitz K, Sandmann W, Stuhmeier K et al (1996) The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms. J Vasc Surg 23:230-240
    • (1996) J Vasc Surg , vol.23 , pp. 230-240
    • Grabitz, K.1    Sandmann, W.2    Stuhmeier, K.3
  • 5
    • 0742323389 scopus 로고    scopus 로고
    • Selective perfusion of preoperatively identified artery of Adamkiewicz during repair of thoracoabdominal aortic aneurysm
    • Ohtsubo S, Itoh T, Okazaki Y, Matsumoto K, Kato A (2004) Selective perfusion of preoperatively identified artery of Adamkiewicz during repair of thoracoabdominal aortic aneurysm. J Thorac Cardiovasc Surg 127:272-274
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 272-274
    • Ohtsubo, S.1    Itoh, T.2    Okazaki, Y.3    Matsumoto, K.4    Kato, A.5
  • 6
    • 0036482033 scopus 로고    scopus 로고
    • Spinal cord arteriography: A safe adjunct before descending thoracic or thoracoabdominal aortic aneurysmectomy
    • Kieffer E, Fukui S, Chiras J, Koskas F, Bahnini A, Cormier E (2002) Spinal cord arteriography: A safe adjunct before descending thoracic or thoracoabdominal aortic aneurysmectomy. J Vasc Surg 35:262-268
    • (2002) J Vasc Surg , vol.35 , pp. 262-268
    • Kieffer, E.1    Fukui, S.2    Chiras, J.3    Koskas, F.4    Bahnini, A.5    Cormier, E.6
  • 8
    • 0036208063 scopus 로고    scopus 로고
    • Demonstration of the artery of Adamkiewicz at multi-detector row helical CT
    • Takase K, Sawamura Y, Igarashi K et al (2002) Demonstration of the artery of Adamkiewicz at multi-detector row helical CT. Radiology 223:39-45
    • (2002) Radiology , vol.223 , pp. 39-45
    • Takase, K.1    Sawamura, Y.2    Igarashi, K.3
  • 9
    • 0142124411 scopus 로고    scopus 로고
    • MR angiography and CT angiography of the artery of Adamkiewicz: Noninvasive preoperative assessment of thoracoabdominal aortic aneurysm
    • Yoshioka K, Niinuma H, Ohira A et al (2003) MR angiography and CT angiography of the artery of Adamkiewicz: Noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics 23:1215-1225
    • (2003) Radiographics , vol.23 , pp. 1215-1225
    • Yoshioka, K.1    Niinuma, H.2    Ohira, A.3
  • 10
    • 0037243206 scopus 로고    scopus 로고
    • Anterior spinal artery and artery of Adamkiewicz detected by using multi-detector row CT
    • Kudo K, Terae S, Asano T et al (2003) Anterior spinal artery and artery of Adamkiewicz detected by using multi-detector row CT. AJNR Am J Neuroradiol 24:13-17
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 13-17
    • Kudo, K.1    Terae, S.2    Asano, T.3
  • 12
    • 0031952417 scopus 로고    scopus 로고
    • Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate-pharmacokinetic analysis and experimental porcine model
    • Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate-pharmacokinetic analysis and experimental porcine model. Radiology 206:455-464
    • (1998) Radiology , vol.206 , pp. 455-464
    • Bae, K.T.1    Heiken, J.P.2    Brink, J.A.3
  • 13
    • 33644980740 scopus 로고    scopus 로고
    • Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: Feasibility study
    • Awai K, Hatcho A, Nakayama Y et al (2006) Simulation of aortic peak enhancement on MDCT using a contrast material flow phantom: Feasibility study. AJR Am J Roentgenol 186:379-385
    • (2006) AJR Am J Roentgenol , vol.186 , pp. 379-385
    • Awai, K.1    Hatcho, A.2    Nakayama, Y.3
  • 14
    • 33947589057 scopus 로고    scopus 로고
    • MR angiography and CT angiography of the artery of Adamkiewicz: State of the art
    • Yoshioka K, Niinuma H, Ehara S, Nakajima T, Nakamura M, Kawazoe K (2006) MR angiography and CT angiography of the artery of Adamkiewicz: State of the art. Radiographics 26(Suppl 1):S63-S73
    • (2006) Radiographics , vol.26 , Issue.SUPPL. 1
    • Yoshioka, K.1    Niinuma, H.2    Ehara, S.3    Nakajima, T.4    Nakamura, M.5    Kawazoe, K.6
  • 15
    • 0033969237 scopus 로고    scopus 로고
    • Improved uniformity of aortic enhancement with customized contrast injection protocols at CT angiography
    • Fleischmann D, Rubin GD, Bankier AA, Hittmair K (2000) Improved uniformity of aortic enhancement with customized contrast injection protocols at CT angiography. Radiology 214:363-371
    • (2000) Radiology , vol.214 , pp. 363-371
    • Fleischmann, D.1    Rubin, G.D.2    Bankier, A.A.3    Hittmair, K.4
  • 16
    • 33947600788 scopus 로고    scopus 로고
    • Comparison of magnetic resonance with computed tomography angiography for preoperative localization of the Adamkiewicz artery in thoracoabdominal aortic aneurysm patients
    • Nijenhuis RJ, Jacobs MJ, Jaspers K et al (2007) Comparison of magnetic resonance with computed tomography angiography for preoperative localization of the Adamkiewicz artery in thoracoabdominal aortic aneurysm patients. J Vasc Surg 45:677-685
    • (2007) J Vasc Surg , vol.45 , pp. 677-685
    • Nijenhuis, R.J.1    Jacobs, M.J.2    Jaspers, K.3
  • 17
    • 33846433123 scopus 로고    scopus 로고
    • The Adamkiewicz artery: Demonstration by intra-arterial computed tomographic angiography
    • Nojiri J, Matsumoto K, Kato A et al (2007) The Adamkiewicz artery: demonstration by intra-arterial computed tomographic angiography. Eur J Cardiothorac Surg 31:249-255
    • (2007) Eur J Cardiothorac Surg , vol.31 , pp. 249-255
    • Nojiri, J.1    Matsumoto, K.2    Kato, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.