메뉴 건너뛰기




Volumn 23, Issue 1, 2008, Pages 73-85

Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems

Author keywords

Heart failure monitoring; Home monitoring; Pacemaker follow up; Remote monitoring; Telecardiology

Indexed keywords

AMBULATORY MONITORING; ARTIFICIAL HEART PACEMAKER; CARDIAC RESYNCHRONIZATION THERAPY; DEFIBRILLATOR; FOLLOW UP; HEALTH CARE COST; HUMAN; PATIENT CARE; PATIENT SAFETY; PRIORITY JOURNAL; QUALITY OF LIFE; REIMBURSEMENT; REMOTE SENSING; REVIEW; TECHNOLOGY; TELECARDIOLOGY; TELEMONITORING;

EID: 53949108334     PISSN: 1383875X     EISSN: 15728595     Source Type: Journal    
DOI: 10.1007/s10840-008-9311-5     Document Type: Review
Times cited : (73)

References (52)
  • 1
    • 44649122064 scopus 로고    scopus 로고
    • HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (IECDs): Description of techniques, indications, personnel, frequency and ethical considerations: Developed in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA)
    • 6
    • B. L. Wilkoff A. Auricchio J. Brugada M. Cowie K. A. Ellenbogen A. M. Gillis 2008 HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (IECDs): description of techniques, indications, personnel, frequency and ethical considerations: developed in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA); and in collaboration with the American College of Cardiology (ACC), the American Heart Association (AHA), the European Society of Cardiology (ESC), the Heart Failure Association of ESC (HFA), and the Heart Failure Society of America (HFSA). Endorsed by the Heart Rhythm Society, the European Heart Rhythm Association (a registered branch of the ESC), the American College of Cardiology, the American Heart Association Europace 10 6 707 725
    • (2008) Europace , vol.10 , pp. 707-725
    • Wilkoff, B.L.1    Auricchio, A.2    Brugada, J.3    Cowie, M.4    Ellenbogen, K.A.5    Gillis, A.M.6
  • 2
    • 44649192645 scopus 로고    scopus 로고
    • ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices)
    • 21
    • A. E. Epstein J. P. Dimarco K. A. Ellenbogen N. A. Estes R. A. Freedman L. S. Gettes 2008 ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons Circulation 117 21 e350 e408
    • (2008) Circulation , vol.117
    • Epstein, A.E.1    Dimarco, J.P.2    Ellenbogen, K.A.3    Estes, N.A.4    Freedman, R.A.5    Gettes, L.S.6
  • 5
    • 33749047463 scopus 로고    scopus 로고
    • New approaches to monitoring heart failure before symptoms appear
    • Suppl 1
    • W. T. Abraham 2006 New approaches to monitoring heart failure before symptoms appear Reviews in Cardiovascular Medicine 7 Suppl 1 S33 S41
    • (2006) Reviews in Cardiovascular Medicine , vol.7
    • Abraham, W.T.1
  • 6
    • 33846289600 scopus 로고    scopus 로고
    • Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: Analysis of a worldwide database
    • Suppl 1
    • A. Lazarus 2007 Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database Pacing and Clinical Electrophysiology 30 Suppl 1 S2 S12
    • (2007) Pacing and Clinical Electrophysiology , vol.30
    • Lazarus, A.1
  • 9
    • 33745213199 scopus 로고    scopus 로고
    • The RIONI study rationale and design: Validation of the first stored electrograms transmitted via Home Monitoring in patients with implantable defibrillators
    • 4
    • C. Perings G. Klein E. Toft C. Moro D. Klug D. Bocker 2006 The RIONI study rationale and design: Validation of the first stored electrograms transmitted via Home Monitoring in patients with implantable defibrillators Europace 8 4 288 292
    • (2006) Europace , vol.8 , pp. 288-292
    • Perings, C.1    Klein, G.2    Toft, E.3    Moro, C.4    Klug, D.5    Bocker, D.6
  • 10
    • 33745572752 scopus 로고    scopus 로고
    • Use of "iEGM online" in ICD patients-early detection of inappropriate classified ventricular tachycardia via Home Monitoring
    • 7
    • O. Ritter W. R. Bauer 2006 Use of "IEGM online" in ICD patients-early detection of inappropriate classified ventricular tachycardia via Home Monitoring Clinical Research in Cardiology; Official Journal of the German Cardiac Society 95 7 368 372
    • (2006) Clinical Research in Cardiology; Official Journal of the German Cardiac Society , vol.95 , pp. 368-372
    • Ritter, O.1    Bauer, W.R.2
  • 13
    • 33749041284 scopus 로고    scopus 로고
    • Integrating monitoring into the infrastructure and workflow of routine practice: OptiVol
    • Suppl 1
    • R. Small 2006 Integrating monitoring into the infrastructure and workflow of routine practice: OptiVol Reviews in Cardiovascular Medicine 7 Suppl 1 S47 S55
    • (2006) Reviews in Cardiovascular Medicine , vol.7
    • Small, R.1
  • 14
    • 34248572239 scopus 로고    scopus 로고
    • Fundamentals of intrathoracic impedance monitoring in heart failure
    • 10A
    • L. Wang 2007 Fundamentals of intrathoracic impedance monitoring in heart failure The American Journal of Cardiology 99 10A 3G 10G
    • (2007) The American Journal of Cardiology , vol.99
    • Wang, L.1
  • 16
    • 34247859642 scopus 로고    scopus 로고
    • Telemonitoring or structured telephone support programmes for patients with chronic heart failure: Systematic review and meta-analysis
    • 7600
    • R. A. Clark S. C. Inglis F. A. McAlister J. G. Cleland S. Stewart 2007 Telemonitoring or structured telephone support programmes for patients with chronic heart failure: Systematic review and meta-analysis BMJ (Clinical Research Ed) 334 7600 942
    • (2007) BMJ (Clinical Research Ed) , vol.334 , pp. 942
    • Clark, R.A.1    Inglis, S.C.2    McAlister, F.A.3    Cleland, J.G.4    Stewart, S.5
  • 19
    • 12844258988 scopus 로고    scopus 로고
    • Detection of atrial fibrillation by implanted devices with wireless data transmission capability
    • Suppl. 1
    • N. Varma B. Stambler S. Chun 2005 Detection of atrial fibrillation by implanted devices with wireless data transmission capability Pacing and Clinical Electrophysiology 28 Suppl. 1 S133 S136
    • (2005) Pacing and Clinical Electrophysiology , vol.28
    • Varma, N.1    Stambler, B.2    Chun, S.3
  • 20
    • 41949103591 scopus 로고    scopus 로고
    • Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: Impact on medical management and health-care resource utilization
    • 2
    • R. P. Ricci L. Morichelli M. Santini 2008 Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: Impact on medical management and health-care resource utilization Europace 10 2 164 170
    • (2008) Europace , vol.10 , pp. 164-170
    • Ricci, R.P.1    Morichelli, L.2    Santini, M.3
  • 22
    • 44649168555 scopus 로고    scopus 로고
    • A prospective multicenter comparison trial of Home Monitoring against regular follow-up in MADIT II patients: Additional visits and cost impact
    • C. Elsner P. Sommer C. Piorkowski M. Taborsky H. Neuser J. Bytesnik 2006 A prospective multicenter comparison trial of Home Monitoring against regular follow-up in MADIT II patients: additional visits and cost impact Computers in Cardiology 33 241 244
    • (2006) Computers in Cardiology , vol.33 , pp. 241-244
    • Elsner, C.1    Sommer, P.2    Piorkowski, C.3    Taborsky, M.4    Neuser, H.5    Bytesnik, J.6
  • 23
    • 36148992980 scopus 로고    scopus 로고
    • Rationale and design of a prospective study of the efficacy of a remote monitoring system used in implantable cardioverter defibrillator follow-up: The Lumos-T Reduces Routine Office Device Follow-Up Study (TRUST) study
    • 6
    • N. Varma 2007 Rationale and design of a prospective study of the efficacy of a remote monitoring system used in implantable cardioverter defibrillator follow-up: The Lumos-T Reduces Routine Office Device Follow-Up Study (TRUST) study American Heart Journal 154 6 1029 1034
    • (2007) American Heart Journal , vol.154 , pp. 1029-1034
    • Varma, N.1
  • 24
  • 26
    • 44349160019 scopus 로고    scopus 로고
    • Early automatic remote detection of combined lead insulation defect and ICD damage
    • 5
    • P. Neuzil M. Taborsky F. Holy K. Wallbrueck 2008 Early automatic remote detection of combined lead insulation defect and ICD damage Europace 10 5 556 557
    • (2008) Europace , vol.10 , pp. 556-557
    • Neuzil, P.1    Taborsky, M.2    Holy, F.3    Wallbrueck, K.4
  • 27
    • 34548321332 scopus 로고    scopus 로고
    • Severe pacemaker lead perforation detected by an automatic home-monitoring system
    • 12
    • S. Spencker D. Mueller A. Marek M. Zabel 2007 Severe pacemaker lead perforation detected by an automatic home-monitoring system European Heart Journal 28 12 1432
    • (2007) European Heart Journal , vol.28 , pp. 1432
    • Spencker, S.1    Mueller, D.2    Marek, A.3    Zabel, M.4
  • 28
    • 33947159735 scopus 로고    scopus 로고
    • Integrated Home Monitoring predicts lead failure in a pacemaker dependent 4-year-old girl
    • 3
    • P. A. Zartner R. P. Handke A. M. Brecher M. B. Schneider 2007 Integrated Home Monitoring predicts lead failure in a pacemaker dependent 4-year-old girl Europace 9 3 192 193
    • (2007) Europace , vol.9 , pp. 192-193
    • Zartner, P.A.1    Handke, R.P.2    Brecher, A.M.3    Schneider, M.B.4
  • 30
    • 33745596606 scopus 로고    scopus 로고
    • Remote detection of incessant slow VT with an ICD capable of Home Monitoring
    • 7
    • S. Siaplaouras A. Buob H. R. Neuberger C. Mewis 2006 Remote detection of incessant slow VT with an ICD capable of Home Monitoring Europace 8 7 512 514
    • (2006) Europace , vol.8 , pp. 512-514
    • Siaplaouras, S.1    Buob, A.2    Neuberger, H.R.3    Mewis, C.4
  • 31
    • 21844439276 scopus 로고    scopus 로고
    • Home Monitoring in an ICD patient with incessant ventricular tachycardia
    • 7
    • R. Koos A. M. Sinha C. Stellbrink 2005 Home Monitoring in an ICD patient with incessant ventricular tachycardia Zeitschrift fur Kardiologie 94 7 461 464
    • (2005) Zeitschrift fur Kardiologie , vol.94 , pp. 461-464
    • Koos, R.1    Sinha, A.M.2    Stellbrink, C.3
  • 32
    • 42449139153 scopus 로고    scopus 로고
    • Design of the Pacemaker REmote Follow-up Evaluation and Review (PREFER) trial to assess the clinical value of the remote pacemaker interrogation in the management of pacemaker patients
    • J. Chen B. L. Wilkoff W. Choucair T. J. Cohen G. H. Crossley W. B. Johnson 2008 Design of the Pacemaker REmote Follow-up Evaluation and Review (PREFER) trial to assess the clinical value of the remote pacemaker interrogation in the management of pacemaker patients Trials 9 18
    • (2008) Trials , vol.9 , pp. 18
    • Chen, J.1    Wilkoff, B.L.2    Choucair, W.3    Cohen, T.J.4    Crossley, G.H.5    Johnson, W.B.6
  • 34
    • 23844525145 scopus 로고    scopus 로고
    • Intrathoracic impedance monitoring in patients with heart failure: Correlation with fluid status and feasibility of early warning preceding hospitalization
    • 6
    • C. M. Yu L. Wang E. Chau R. H. Chan S. L. Kong M. O. Tang 2005 Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization Circulation 112 6 841 848
    • (2005) Circulation , vol.112 , pp. 841-848
    • Yu, C.M.1    Wang, L.2    Chau, E.3    Chan, R.H.4    Kong, S.L.5    Tang, M.O.6
  • 37
    • 34248633374 scopus 로고    scopus 로고
    • Remote Active Monitoring in Patients with Heart Failure (RAPID-RF): Design and rationale
    • 4
    • L. A. Saxon J. P. Boehmer S. Neuman C. M. Mullin 2007 Remote Active Monitoring in Patients with Heart Failure (RAPID-RF): Design and rationale Journal of Cardiac Failure 13 4 241 246
    • (2007) Journal of Cardiac Failure , vol.13 , pp. 241-246
    • Saxon, L.A.1    Boehmer, J.P.2    Neuman, S.3    Mullin, C.M.4
  • 38
    • 33749061476 scopus 로고    scopus 로고
    • Recommendations from the Heart Rhythm Society Task Force on Device Performance Policies and Guidelines Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA) and the International Coalition of Pacing and Electrophysiology Organizations (COPE)
    • 10
    • M. D. Carlson B. L. Wilkoff W. H. Maisel M. D. Carlson K. A. Ellenbogen L. A. Saxon 2006 Recommendations from the Heart Rhythm Society Task Force on Device Performance Policies and Guidelines Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA) and the International Coalition of Pacing and Electrophysiology Organizations (COPE) Heart Rhythm 3 10 1250 1273
    • (2006) Heart Rhythm , vol.3 , pp. 1250-1273
    • Carlson, M.D.1    Wilkoff, B.L.2    Maisel, W.H.3    Carlson, M.D.4    Ellenbogen, K.A.5    Saxon, L.A.6
  • 39
    • 33846307443 scopus 로고    scopus 로고
    • The device recalls nightmare: Help might be on the way
    • Suppl 1
    • R. Ruffy 2007 The device recalls nightmare: Help might be on the way Pacing and Clinical Electrophysiology 30 Suppl 1 S1
    • (2007) Pacing and Clinical Electrophysiology , vol.30 , pp. 1
    • Ruffy, R.1
  • 40
  • 41
    • 44649119926 scopus 로고    scopus 로고
    • Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator
    • 3
    • H. Heidbuchel P. Lioen S. Foulon W. Huybrechts J. Ector R. Willems 2008 Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator Europace 10 3 351 357
    • (2008) Europace , vol.10 , pp. 351-357
    • Heidbuchel, H.1    Lioen, P.2    Foulon, S.3    Huybrechts, W.4    Ector, J.5    Willems, R.6
  • 43
    • 34547936744 scopus 로고    scopus 로고
    • Physiological approach to monitor patients in congestive heart failure: Application of a new implantable device-based system to monitor daily life activity and ventilation
    • 8
    • E. Page S. Cazeau P. Ritter D. Galley C. Casset 2007 Physiological approach to monitor patients in congestive heart failure: Application of a new implantable device-based system to monitor daily life activity and ventilation Europace 9 8 687 693
    • (2007) Europace , vol.9 , pp. 687-693
    • Page, E.1    Cazeau, S.2    Ritter, P.3    Galley, D.4    Casset, C.5
  • 47
    • 40649118759 scopus 로고    scopus 로고
    • Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: The COMPASS-HF study
    • 11
    • R. C. Bourge W. T. Abraham P. B. Adamson M. F. Aaron J. M. Aranda A. Magalski 2008 Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure: The COMPASS-HF study Journal of the American College of Cardiology 51 11 1073 1079
    • (2008) Journal of the American College of Cardiology , vol.51 , pp. 1073-1079
    • Bourge, R.C.1    Abraham, W.T.2    Adamson, P.B.3    Aaron, M.F.4    Aranda, J.M.5    Magalski, A.6
  • 48
    • 33745593723 scopus 로고    scopus 로고
    • Determination of left ventricular volume changes by intracardiac conductance using a biventricular electrode configuration
    • 7
    • E. Zima M. Lippert G. Czygan B. Merkely 2006 Determination of left ventricular volume changes by intracardiac conductance using a biventricular electrode configuration Europace 8 7 537 544
    • (2006) Europace , vol.8 , pp. 537-544
    • Zima, E.1    Lippert, M.2    Czygan, G.3    Merkely, B.4
  • 51
    • 45849110223 scopus 로고    scopus 로고
    • Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: Early clinical results
    • 7
    • P. P. Delnoy E. Marcelli H. Oudeluttikhuis D. Nicastia F. Renesto L. Cercenelli 2008 Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: Early clinical results Europace 10 7 801 808
    • (2008) Europace , vol.10 , pp. 801-808
    • Delnoy, P.P.1    Marcelli, E.2    Oudeluttikhuis, H.3    Nicastia, D.4    Renesto, F.5    Cercenelli, L.6
  • 52
    • 33845678587 scopus 로고    scopus 로고
    • Intrathoracic far-field electrocardiogram allows continuous monitoring of ischemia after total coronary occlusion
    • 12
    • S. Asbach I. Weiss B. Wenzel C. Bode M. Zehender 2006 Intrathoracic far-field electrocardiogram allows continuous monitoring of ischemia after total coronary occlusion Pacing and Clinical Electrophysiology 29 12 1334 1340
    • (2006) Pacing and Clinical Electrophysiology , vol.29 , pp. 1334-1340
    • Asbach, S.1    Weiss, I.2    Wenzel, B.3    Bode, C.4    Zehender, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.