Volumn , Issue , 2007, Pages 209-217

Mechanical properties of α + β type titanium alloys fabricated by metal injection molding with targetting biomedical applications

Author keywords

Biomedical application; Mechanical properties; Metal injection molding; Ti 6A1 4V; Ti 6Al 4V 3Mo

Indexed keywords

ALUMINUM; ANNEALING; APPLICATIONS; ELECTRIC FIELD EFFECTS; ELONGATION; FATIGUE OF MATERIALS; FORMING; HEAT TREATING FURNACES; HEAT TREATMENT; HOT ISOSTATIC PRESSING; HOT PRESSING; HOT ROLLING; HOT ROLLING MILLS; HOT WORKING; IMPLANTS (SURGICAL); INJECTION MOLDING; INNOVATION; LIFE CYCLE; MECHANICAL PROPERTIES; MEDICAL APPLICATIONS; METAL ANALYSIS; METAL MOLDING; METAL WORKING; METALLIC COMPOUNDS; MIM DEVICES; MOLDING; MOLDS; MOLYBDENUM; PLASTIC MOLDS; STRENGTH OF MATERIALS; TENSILE STRENGTH; TITANIUM;

EID: 53949096105     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (13)

References (6)
  • 1
    • 17044397754 scopus 로고    scopus 로고
    • Dental Precision Casting of Ti-29Nb-13Ta-4.6Zr Using Calcia Mold
    • M. Niinomi et al., "Dental Precision Casting of Ti-29Nb-13Ta-4.6Zr Using Calcia Mold", Materials Science Forum, 475-479(2005), 2303-2308.
    • (2005) Materials Science Forum , vol.475-479 , pp. 2303-2308
    • Niinomi, M.1
  • 2
    • 21444441681 scopus 로고    scopus 로고
    • Mechanical Properties and Cyto-toxicity of Newly Designed Beta Type Titanium Alloys with Low Melting Points for Dental Applications
    • M. Niinomi, "Mechanical Properties and Cyto-toxicity of Newly Designed Beta Type Titanium Alloys with Low Melting Points for Dental Applications", Materials Science and Engineering C, 25(2005), 417-425.
    • (2005) Materials Science and Engineering C , vol.25 , pp. 417-425
    • Niinomi, M.1
  • 3
    • 85007880339 scopus 로고
    • Tensile Behavior of Sintered Titanium by MIM Process
    • K. Kusaka, "Tensile Behavior of Sintered Titanium by MIM Process", J. Jpn. Soc. Powder Metallurgy, 42(1995), 383-387.
    • (1995) J. Jpn. Soc. Powder Metallurgy , vol.42 , pp. 383-387
    • Kusaka, K.1
  • 4
    • 24944536088 scopus 로고    scopus 로고
    • Use of a Naphthalene-Based Binder in Injection Molding Net-Shape Titanium Components of Controlled Porosity
    • K. S. Scott et al., "Use of a Naphthalene-Based Binder in Injection Molding Net-Shape Titanium Components of Controlled Porosity"', Materials Transactions, 46(2005), 1525-1531.
    • (2005) Materials Transactions , vol.46 , pp. 1525-1531
    • Scott, K.S.1
  • 5
    • 53949109307 scopus 로고
    • A Study on Sintered Titanium Alloy as a Biomaterials
    • K. Majima et al., "A Study on Sintered Titanium Alloy as a Biomaterials", J. Jpn. Soc. for Biomaterials, 10(1992), 3-10.
    • (1992) J. Jpn. Soc. for Biomaterials , vol.10 , pp. 3-10
    • Majima, K.1
  • 6
    • 53949102165 scopus 로고    scopus 로고
    • Fabrication of Ti-6Al-7Nb Alloys by Metal Injection Molding
    • to be published
    • Y. Itoh et al., "Fabrication of Ti-6Al-7Nb Alloys by Metal Injection Molding", Proc. Proc. PM'2006, (2006), to be published.
    • (2006) Proc. Proc. PM
    • Itoh, Y.1