메뉴 건너뛰기




Volumn 149, Issue 38, 2008, Pages 1779-1784

New therapy for atrial fibrillation: Pulmonary vein isolation by cryoballoon ablation;A paroxizmális pitvarfibrilláció kezelésének új módszere: Cryoballonos pulmonalis véna cirkumferenciális ablatiója

Author keywords

Arrhytmia; Atrial fibrillation; Catheter ablation; Cryoballoon; Pulmonary veins

Indexed keywords

AORTOESOPHAGEAL FISTULA; ARTICLE; BALLOON CATHETER; CATHETER ABLATION; CLINICAL EFFECTIVENESS; CRYOABLATION; ENERGY RESOURCE; HEART ATRIUM FIBRILLATION; HUMAN; HUNGARY; INTERMETHOD COMPARISON; PATIENT SAFETY; PULMONARY VEIN; PULMONARY VEIN OBSTRUCTION; RADIOFREQUENCY ABLATION; RADIOFREQUENCY RADIATION;

EID: 53849141225     PISSN: 00306002     EISSN: 17886120     Source Type: Journal    
DOI: 10.1556/OH.2008.28454     Document Type: Article
Times cited : (3)

References (16)
  • 1
    • 0035155445 scopus 로고    scopus 로고
    • Fuster, V., Rydén, L. E., Asinger, R. W. és mtsai: ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation. Eur. Heart J., 2001, 22, 1852-1923.
    • Fuster, V., Rydén, L. E., Asinger, R. W. és mtsai: ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation. Eur. Heart J., 2001, 22, 1852-1923.
  • 2
    • 0032497292 scopus 로고    scopus 로고
    • Benjamin, E. J., Wolf, P. A., D'Agostino, R. B. és mtsai: Impact of atrial fibrillation on the risk of death. The Framingham Heart Study. Circulation, 1998, 98, 946-952.
    • Benjamin, E. J., Wolf, P. A., D'Agostino, R. B. és mtsai: Impact of atrial fibrillation on the risk of death. The Framingham Heart Study. Circulation, 1998, 98, 946-952.
  • 3
    • 0028092959 scopus 로고    scopus 로고
    • Haissagguere, M., Marcus, F. I., Shah, D. C. és mtsai: Radio-frequency catheter ablation in unusual mechanism of atrial fibrillation: report of three cases. J. Cardiovasc. Electrophysiol., 1994, 5, 743-751.
    • Haissagguere, M., Marcus, F. I., Shah, D. C. és mtsai: Radio-frequency catheter ablation in unusual mechanism of atrial fibrillation: report of three cases. J. Cardiovasc. Electrophysiol., 1994, 5, 743-751.
  • 4
    • 0343729318 scopus 로고    scopus 로고
    • Haissaguerre, M., Shah, D. C., Marcus, F. I. és mtsai: Electro-physiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci. Circulation, 2000, 101, 1409-1417.
    • Haissaguerre, M., Shah, D. C., Marcus, F. I. és mtsai: Electro-physiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci. Circulation, 2000, 101, 1409-1417.
  • 5
    • 20144363969 scopus 로고    scopus 로고
    • Cappato, R., Calkins, H., Chen, S. A. és mtsai: A worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation, 2005, 111, 1100-1105.
    • Cappato, R., Calkins, H., Chen, S. A. és mtsai: A worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation, 2005, 111, 1100-1105.
  • 6
    • 20844433860 scopus 로고    scopus 로고
    • Pappone, C., Manguso, F., Vicedomini, G. és mtsai: Prevention of iatrogenic atrial tachycardia after ablation of atrial fibrillation: a prospective randomized study comparing circumferential pulmonary vein ablation with a modified approach. Circulation, 2004, 110, 3036-3042.
    • Pappone, C., Manguso, F., Vicedomini, G. és mtsai: Prevention of iatrogenic atrial tachycardia after ablation of atrial fibrillation: a prospective randomized study comparing circumferential pulmonary vein ablation with a modified approach. Circulation, 2004, 110, 3036-3042.
  • 7
    • 0037432308 scopus 로고    scopus 로고
    • J. és mtsa: Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception
    • Timmermans, C., Ayers, G. M., Crijns, H. J. és mtsa: Randomized study comparing radiofrequency ablation with cryoablation for the treatment of atrial flutter with emphasis on pain perception. Circulation, 2003, 107, 1250-1252
    • (2003) Circulation , vol.107 , pp. 1250-1252
    • Timmermans, C.1    Ayers, G.M.2    Crijns, H.3
  • 8
    • 0035058539 scopus 로고    scopus 로고
    • Dubuc, M., Khairy, P., Rodriguez-Santiago, A. és mtsai: Catheter cryoablation of the atrioventricular node in patients with atrial fibrillation: a novel technology for ablation of cardiac arrhythmias. J. Cardiovasc. Electrophysiol., 2001, 12, 439-444.
    • Dubuc, M., Khairy, P., Rodriguez-Santiago, A. és mtsai: Catheter cryoablation of the atrioventricular node in patients with atrial fibrillation: a novel technology for ablation of cardiac arrhythmias. J. Cardiovasc. Electrophysiol., 2001, 12, 439-444.
  • 9
    • 27644568168 scopus 로고    scopus 로고
    • Sarabanda, A. V., Bunch, T. J., Johnson, S. B. és mtsai: Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. J. Am. Coll. Cardiol., 2005, 46, 1902-1912.
    • Sarabanda, A. V., Bunch, T. J., Johnson, S. B. és mtsai: Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. J. Am. Coll. Cardiol., 2005, 46, 1902-1912.
  • 10
    • 47149112945 scopus 로고    scopus 로고
    • Neumann, T., Vogt, J., Schumacher, B. és mtsai: Circumferential pulmonary vein isolation with the cryoballon technique. JACC, 2008, 52, 273-278.
    • Neumann, T., Vogt, J., Schumacher, B. és mtsai: Circumferential pulmonary vein isolation with the cryoballon technique. JACC, 2008, 52, 273-278.
  • 11
    • 34548803112 scopus 로고    scopus 로고
    • J. és mtsai: Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome
    • Van Belle, Y., Janse, P., Rivero-Ayerza, M. J. és mtsai: Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur. Heart J., 2007, 28, 2231-2237.
    • (2007) Eur. Heart J , vol.28 , pp. 2231-2237
    • Van Belle, Y.1    Janse, P.2    Rivero-Ayerza, M.3
  • 12
    • 34547903168 scopus 로고    scopus 로고
    • Calkins, H, Brugada, J, Packer, D. L. és mtsai: HRS/EHRA/ ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS, in collaboration with the American College of Cardiology (ACC, American Heart Association (AHA, and the Society of Thoracic Surgeons STS, Endorsed and approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society. Europace, 2007, 9, 335-379
    • Calkins, H., Brugada, J., Packer, D. L. és mtsai: HRS/EHRA/ ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society. Europace, 2007, 9, 335-379.
  • 13
    • 34247523351 scopus 로고    scopus 로고
    • Natale, A., Raviele, A., Arentz, T. és mtsai: Venice Chart international consensus document on atrial fibrillation ablation. J. Cardiovasc. Electrophysiol., 2007, 18, 560-580.
    • Natale, A., Raviele, A., Arentz, T. és mtsai: Venice Chart international consensus document on atrial fibrillation ablation. J. Cardiovasc. Electrophysiol., 2007, 18, 560-580.
  • 14
    • 33846388529 scopus 로고    scopus 로고
    • Nakagawa, H., Antz, M., Wong, T. és mtsai: Initial experience using a forward directed, high-intensity focused ultrasound balloon catheter for pulmonary vein antrum isolation in patients with atrial fibrillation. Pacing Clin. Electrophysiol., 2007, 18, 136-144.
    • Nakagawa, H., Antz, M., Wong, T. és mtsai: Initial experience using a forward directed, high-intensity focused ultrasound balloon catheter for pulmonary vein antrum isolation in patients with atrial fibrillation. Pacing Clin. Electrophysiol., 2007, 18, 136-144.
  • 15
    • 9144272549 scopus 로고    scopus 로고
    • Reddy, V. Y., Houghtaling, C., Fallon, J. és mtsai: Use diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model. Pacing Clin. Electrophysiol., 2004, 27, 52-57.
    • Reddy, V. Y., Houghtaling, C., Fallon, J. és mtsai: Use diode laser balloon ablation catheter to generate circumferential pulmonary venous lesions in an open-thoracotomy caprine model. Pacing Clin. Electrophysiol., 2004, 27, 52-57.
  • 16
    • 4444229385 scopus 로고    scopus 로고
    • Scanavacca, M. I., D'avila, A., Parga, J. és mtsa: Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation. J. Cardiovasc. Electrophysiol., 2004, 15, 960-962.
    • Scanavacca, M. I., D'avila, A., Parga, J. és mtsa: Left atrial-esophageal fistula following radiofrequency catheter ablation of atrial fibrillation. J. Cardiovasc. Electrophysiol., 2004, 15, 960-962.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.