메뉴 건너뛰기




Volumn 13, Issue 5, 2008, Pages 291-294

Reproducibility of systemic hemodynamics in stable chronic hemodialysis: A pilot study

Author keywords

Cardiac output; Hemodialysis; Hemodynamic monitoring; Renal dialysis; Reproducibility of results'; Vascular resistance

Indexed keywords

ADULT; AGED; ARTERY COMPLIANCE; ARTICLE; BLOOD PRESSURE MONITORING; BLOOD VESSEL COMPLIANCE; CLINICAL ARTICLE; DIASTOLIC BLOOD PRESSURE; HEART INDEX; HEART LEFT VENTRICLE DP-DT; HEMODIALYSIS; HEMODIALYSIS PATIENT; HEMODYNAMIC MONITORING; HEMODYNAMIC PARAMETERS; HEMODYNAMICS; HUMAN; MALE; MONITOR; OSCILLOMETRY; PILOT STUDY; PRIORITY JOURNAL; REPRODUCIBILITY; STANDING; SUPINE POSITION; SYSTEMIC VASCULAR RESISTANCE; SYSTOLIC BLOOD PRESSURE; WEIGHT GAIN;

EID: 53549133358     PISSN: 13595237     EISSN: None     Source Type: Journal    
DOI: 10.1097/MBP.0b013e3283057ae4     Document Type: Article
Times cited : (1)

References (12)
  • 2
    • 0029846106 scopus 로고    scopus 로고
    • Arterial compliance by cuff sphygmomanometer. Application to hypertension and early changes in subjects at genetic risk
    • Brinton TJ, Kailasam MT, Wu RA, Cervenka JH, Chio SS, Parmer RJ, et al. Arterial compliance by cuff sphygmomanometer. Application to hypertension and early changes in subjects at genetic risk. Hypertension 1996; 28:599-603.
    • (1996) Hypertension , vol.28 , pp. 599-603
    • Brinton, T.J.1    Kailasam, M.T.2    Wu, R.A.3    Cervenka, J.H.4    Chio, S.S.5    Parmer, R.J.6
  • 3
    • 33745150444 scopus 로고    scopus 로고
    • Reliability of a non-invasive device to measure systemic hemodynamics in hemodialysis patients
    • Motiwala S, Brewster U, Perazella MA, Peixoto AJ. Reliability of a non-invasive device to measure systemic hemodynamics in hemodialysis patients. Blood Pressure Monitoring 2006; 11:33-36.
    • (2006) Blood Pressure Monitoring , vol.11 , pp. 33-36
    • Motiwala, S.1    Brewster, U.2    Perazella, M.A.3    Peixoto, A.J.4
  • 4
    • 0035011236 scopus 로고    scopus 로고
    • The (dP/dt)max derived from arterial pulse waveforms: Prospective applications in the hemodialysis setting
    • Kyriazis J, Glotsos J, Bilirakis L, Smirnioudis N. The (dP/dt)max derived from arterial pulse waveforms: prospective applications in the hemodialysis setting. Nephrol Dial Transplant 2001; 16: 1087-1088.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 1087-1088
    • Kyriazis, J.1    Glotsos, J.2    Bilirakis, L.3    Smirnioudis, N.4
  • 7
    • 37349070985 scopus 로고    scopus 로고
    • Development and validation of a noninvasive method to estimate cardiac output using cuff sphygmomanometry
    • Chio SS, Tsai J, Hsu Y, Lapointe J, Covey HT, Kwang L, DeMaria A. Development and validation of a noninvasive method to estimate cardiac output using cuff sphygmomanometry. Clin Cardiol 2007; 30: 615-620.
    • (2007) Clin Cardiol , vol.30 , pp. 615-620
    • Chio, S.S.1    Tsai, J.2    Hsu, Y.3    Lapointe, J.4    Covey, H.T.5    Kwang, L.6    DeMaria, A.7
  • 8
    • 0028600665 scopus 로고
    • Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology
    • Cicchetti DV. Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology. Psychol Assess 1994; 6:284-290.
    • (1994) Psychol Assess , vol.6 , pp. 284-290
    • Cicchetti, D.V.1
  • 9
    • 19544369477 scopus 로고    scopus 로고
    • Non-invasive monitoring of hemodynamic changes during hemodialysis by the use of a newly developed admittance cardiograph
    • Yoshii M, Minami J, Ishimitsu T, Yamakoshi K, Matsuoka H. Non-invasive monitoring of hemodynamic changes during hemodialysis by the use of a newly developed admittance cardiograph. Ther Apher Dial 2005; 9: 154-160.
    • (2005) Ther Apher Dial , vol.9 , pp. 154-160
    • Yoshii, M.1    Minami, J.2    Ishimitsu, T.3    Yamakoshi, K.4    Matsuoka, H.5
  • 10
    • 0036142807 scopus 로고    scopus 로고
    • Hemodynamics in patients with intradialytic hypotension treated with cool dialysate or midodrine
    • Hoeben H, Abu-Alfa AK, Mahnensmith R, Perazella MA. Hemodynamics in patients with intradialytic hypotension treated with cool dialysate or midodrine. Am J Kidney Dis 2002; 39:102-107.
    • (2002) Am J Kidney Dis , vol.39 , pp. 102-107
    • Hoeben, H.1    Abu-Alfa, A.K.2    Mahnensmith, R.3    Perazella, M.A.4
  • 11
    • 1642382811 scopus 로고    scopus 로고
    • Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: Implications in clinical practice
    • Ishibe S, Peixoto AJ. Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: implications in clinical practice. Semin Dial 2004; 17:37-43.
    • (2004) Semin Dial , vol.17 , pp. 37-43
    • Ishibe, S.1    Peixoto, A.J.2
  • 12
    • 33746554946 scopus 로고    scopus 로고
    • Impedance cardiography derived cardiac output in hemodialysis patients: A study of reproducibility and comparison with echocardiography
    • Karakitsos DN, Patrianakos AP, Paraskevopoulos A, Parthenakis Fl, Tzenakis N, Fourtounas C, et al. Impedance cardiography derived cardiac output in hemodialysis patients: a study of reproducibility and comparison with echocardiography. Int J Artil Organs 2006; 29:564-572.
    • (2006) Int J Artil Organs , vol.29 , pp. 564-572
    • Karakitsos, D.N.1    Patrianakos, A.P.2    Paraskevopoulos, A.3    Parthenakis, F.4    Tzenakis, N.5    Fourtounas, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.