메뉴 건너뛰기




Volumn 29, Issue 1, 2009, Pages 37-46

Numerical analysis on the effects of refrigerant injection on the scroll compressor

Author keywords

Inner compression process; Refrigerant injection; Scroll compressor

Indexed keywords

COMPRESSION RATIO (MACHINERY); COMPRESSORS; NUMERICAL ANALYSIS; REFRIGERANTS;

EID: 53549097928     PISSN: 13594311     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.applthermaleng.2008.01.025     Document Type: Article
Times cited : (78)

References (14)
  • 1
    • 33845215651 scopus 로고    scopus 로고
    • Design of experimental bench and internal pressure measurement of scroll compressor with refrigerant injection
    • Wang B., Li X., Shi W., and Yan Q. Design of experimental bench and internal pressure measurement of scroll compressor with refrigerant injection. International Journal of Refrigeration 30 (2007) 179-186
    • (2007) International Journal of Refrigeration , vol.30 , pp. 179-186
    • Wang, B.1    Li, X.2    Shi, W.3    Yan, Q.4
  • 2
    • 53549107565 scopus 로고    scopus 로고
    • B. Wang, Study on the scroll compressor with refrigerant injection and its application, Ph.D. Thesis of Tsinghua University, China, 2006.
    • B. Wang, Study on the scroll compressor with refrigerant injection and its application, Ph.D. Thesis of Tsinghua University, China, 2006.
  • 3
    • 53549112870 scopus 로고    scopus 로고
    • S. Ayub, J.W. Bush, D.K. Haller, Liquid refrigerant injection in scroll compressors operating at high compression ration, in: Proceedings of the International Compressor Engineering Conference at Purdue, 1992, pp. 561-567.
    • S. Ayub, J.W. Bush, D.K. Haller, Liquid refrigerant injection in scroll compressors operating at high compression ration, in: Proceedings of the International Compressor Engineering Conference at Purdue, 1992, pp. 561-567.
  • 4
    • 0035452618 scopus 로고    scopus 로고
    • An investigation of the performance of a scroll compressor under liquid refrigerant injection
    • Dutta A.K., Yanagisawa T., and Fukuta M. An investigation of the performance of a scroll compressor under liquid refrigerant injection. International Journal of Refrigeration 24 (2001) 577-587
    • (2001) International Journal of Refrigeration , vol.24 , pp. 577-587
    • Dutta, A.K.1    Yanagisawa, T.2    Fukuta, M.3
  • 5
    • 0036883490 scopus 로고    scopus 로고
    • Scroll compressors using gas and liquid injection: experimental analysis and modeling
    • Winandy E.L., and Lebrun J. Scroll compressors using gas and liquid injection: experimental analysis and modeling. International Journal of Refrigeration 25 (2002) 1143-1156
    • (2002) International Journal of Refrigeration , vol.25 , pp. 1143-1156
    • Winandy, E.L.1    Lebrun, J.2
  • 6
    • 53549118691 scopus 로고    scopus 로고
    • H. Yamazaki, T. Itoh, K. Sato, H. Kobayashi. High performance scroll compressor with liquid refrigerant injection, in: Proceedings of the International Compressor Engineering Conference at Purdue, 2002, C22-1.
    • H. Yamazaki, T. Itoh, K. Sato, H. Kobayashi. High performance scroll compressor with liquid refrigerant injection, in: Proceedings of the International Compressor Engineering Conference at Purdue, 2002, C22-1.
  • 7
    • 0037211454 scopus 로고    scopus 로고
    • Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor
    • Cho H., Chung J.T., and Kim Y. Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor. International Journal of Refrigeration 26 (2003) 87-94
    • (2003) International Journal of Refrigeration , vol.26 , pp. 87-94
    • Cho, H.1    Chung, J.T.2    Kim, Y.3
  • 8
    • 0036883468 scopus 로고    scopus 로고
    • Thermodynamic analysis on the performance of a variable speed scroll compressor with refrigerant injection
    • Park Y.C., Kim Y., and Cho H. Thermodynamic analysis on the performance of a variable speed scroll compressor with refrigerant injection. International Journal of Refrigeration v25 (2002) 1072-1082
    • (2002) International Journal of Refrigeration v25 , pp. 1072-1082
    • Park, Y.C.1    Kim, Y.2    Cho, H.3
  • 9
    • 53549083874 scopus 로고    scopus 로고
    • M. Zehnder, D. Favrat, H. Hohl, C. Olivier, M. Perevozchikov. High performance air-water heat pump with extended application range for residential heating, in: The 7th International Energy Agency Conference on Heating Pumping Technologies, 2002, pp. 19-22.
    • M. Zehnder, D. Favrat, H. Hohl, C. Olivier, M. Perevozchikov. High performance air-water heat pump with extended application range for residential heating, in: The 7th International Energy Agency Conference on Heating Pumping Technologies, 2002, pp. 19-22.
  • 10
    • 0037211453 scopus 로고    scopus 로고
    • Experimental investigation of air source heat pump for cold regions
    • Ma G., Chai Q., and Jiang Y. Experimental investigation of air source heat pump for cold regions. International Journal of Refrigeration 26 (2003) 12-18
    • (2003) International Journal of Refrigeration , vol.26 , pp. 12-18
    • Ma, G.1    Chai, Q.2    Jiang, Y.3
  • 11
    • 0038002642 scopus 로고    scopus 로고
    • Vapor-injection Scroll Compressors
    • Beeton W.L., and Pham H.M. Vapor-injection Scroll Compressors. ASHRAE Journal 45 4 (2003) 22-27
    • (2003) ASHRAE Journal , vol.45 , Issue.4 , pp. 22-27
    • Beeton, W.L.1    Pham, H.M.2
  • 12
    • 53549135037 scopus 로고    scopus 로고
    • N.P. Halm. Mathematical model of scroll compressor, Master Thesis of Purdue University, USA, 1997.
    • N.P. Halm. Mathematical model of scroll compressor, Master Thesis of Purdue University, USA, 1997.
  • 13
    • 38349155850 scopus 로고    scopus 로고
    • Numerical research on the scroll compressor with refrigeration injection
    • 10.1016/j.applthermaleng.2007.05.012
    • Wang B., Shi W., Li X., and Yan Q. Numerical research on the scroll compressor with refrigeration injection. Applied Thermal Engineering (2007) 10.1016/j.applthermaleng.2007.05.012
    • (2007) Applied Thermal Engineering
    • Wang, B.1    Shi, W.2    Li, X.3    Yan, Q.4
  • 14
    • 53549116568 scopus 로고    scopus 로고
    • T. Hirano, N. Mutsumura, K. Takeda, Development of high efficiency scroll compressors for air conditioners, in: Proceedings of the International Compressor Engineering Conference at Purdue, 1988, 65-74.
    • T. Hirano, N. Mutsumura, K. Takeda, Development of high efficiency scroll compressors for air conditioners, in: Proceedings of the International Compressor Engineering Conference at Purdue, 1988, 65-74.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.