메뉴 건너뛰기




Volumn 17, Issue 3, 2008, Pages 317-324

Hemodynamic performance of fresh and calcified aortic valve prostheses in critical low stroke volume

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; ANIMAL MODEL; AORTA VALVE; ARTICLE; BIOLOGICAL MODEL; BIOMECHANICS; CALCINOSIS; CARDIOMYOPATHY; COMPARATIVE STUDY; DIASTOLE; HEART STROKE VOLUME; HEART VALVE PROSTHESIS; IN VITRO STUDY; PATHOPHYSIOLOGY; PHYSIOLOGY; SWINE; SYSTOLE;

EID: 53449097431     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (19)
  • 2
    • 33644876127 scopus 로고    scopus 로고
    • Risk factors for congestive heart failure after aortic valve replacement with a Carpentier-Edwards pericardial prosthesis in the elderly
    • Mistiaen WP, Van Cauwelaert P, Muylaert P, Wuyts F, Bortier H. Risk factors for congestive heart failure after aortic valve replacement with a Carpentier-Edwards pericardial prosthesis in the elderly. J Heart Valve Dis 2005;14:774-779
    • (2005) J Heart Valve Dis , vol.14 , pp. 774-779
    • Mistiaen, W.P.1    Van Cauwelaert, P.2    Muylaert, P.3    Wuyts, F.4    Bortier, H.5
  • 3
    • 24644480938 scopus 로고    scopus 로고
    • Predictors of low cardiac output syndrome after isolated aortic valve surgery
    • DOI 10.1161/CIRCULATIONAHA.104.526087
    • Maganti MD, Rao V, Borger MA, Ivanov J, David TE. Predictors of low cardiac output syndrome after isolated aortic valve surgery. Circulation 2005;112(9 Suppl.):I448-I452 (Pubitemid 41266713)
    • (2005) Circulation , vol.112 , Issue.9 SUPPL.
    • Maganti, M.D.1    Rao, V.2    Borger, M.A.3    Ivanov, J.4    David, T.E.5
  • 4
    • 0030817763 scopus 로고    scopus 로고
    • Continuing dilemmas concerning aortic valve replacement in patients with advanced left ventricular systolic dysfunction
    • Green GR, Miller DC. Continuing dilemmas concerning aortic valve replacement in patients with advanced left ventricular systolic dysfunction. J Heart Valve Dis 1997;6:562-579 (Pubitemid 27524028)
    • (1997) Journal of Heart Valve Disease , vol.6 , Issue.6 , pp. 562-579
    • Green, G.R.1    Miller, D.C.2
  • 5
    • 0018257807 scopus 로고
    • In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates
    • Gabbay S, McQueen DM, Yellin EL, Becker RM, Fraíer RW. In vitro hydrodynamic comparison of mitral valve prostheses at high flow rates. J Thorac Cardiovasc Surg 1978;76:771-787 (Pubitemid 9084845)
    • (1978) Journal of Thoracic and Cardiovascular Surgery , vol.76 , Issue.6 , pp. 771-787
    • Gabbay, S.1    McQueen, D.M.2    Yellin, E.L.3
  • 7
    • 0021194701 scopus 로고
    • Cardiovascular simulation models
    • Reul H. Cardiovascular simulation models. Life Support Syst 1984;2:77-97
    • (1984) Life Support Syst , vol.2 , pp. 77-97
    • Reul, H.1
  • 11
    • 0034843892 scopus 로고    scopus 로고
    • Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis
    • DOI 10.1016/S0003-4975(01)02992-7, PII S0003497501029927
    • Banbury MK, Cosgrove DM, III, White JA, Blackstone EH, Frater RW, Okies JE. Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis. Ann Thorac Surg 2001;72:753-757 (Pubitemid 32846222)
    • (2001) Annals of Thoracic Surgery , vol.72 , Issue.3 , pp. 753-757
    • Banbury, M.K.1    Cosgrove III, D.M.2    White, J.A.3    Blackstone, E.H.4    Frater, R.W.M.5    Okies, J.E.6
  • 12
    • 14244250309 scopus 로고    scopus 로고
    • The St. Jude Medical cardiac valve prosthesis: A 25-year experience with single valve replacement
    • Emery RW, Krogh CC, Arom KV, et al. The St. Jude Medical cardiac valve prosthesis: A 25-year experience with single valve replacement. Ann Thorac Surg 2005;79:776-783
    • (2005) Ann Thorac Surg , vol.79 , pp. 776-783
    • Emery, R.W.1    Krogh, C.C.2    Arom, K.V.3
  • 14
    • 5144229109 scopus 로고    scopus 로고
    • The effective orifice area/patient aortic annulus area ratio: A better way to compare different bioprostheses? A prospective randomized comparison of the Mosaic and Perimount bioprostheses in the aortic position
    • Eichinger WB, Botzenhardt F, Guenzinger R, et al. The effective orifice area/patient aortic annulus area ratio: A better way to compare different bioprostheses? A prospective randomized comparison of the Mosaic and Perimount bioprostheses in the aortic position. J Heart Valve Dis 2004;13:382-388
    • (2004) J Heart Valve Dis , vol.13 , pp. 382-388
    • Eichinger, W.B.1    Botzenhardt, F.2    Guenzinger, R.3
  • 16
    • 0031859912 scopus 로고    scopus 로고
    • The hemodynamic effects of mechanical prosthetic valve type and orientation on fluid mechanical energy loss and pressure drop in in vitro models of ventricular hypertrophy
    • Travis BR, Heinrich RS, Ensley AE, Gibson DE, Hashim S, Yoganathan AP. The hemodynamic effects of mechanical prosthetic type and orientation on fluid mechanical energy loss and pressure drop in in-vitro models of ventricular hypertrophy. J Heart Valve Dis 1998;7:345-354 (Pubitemid 28266858)
    • (1998) Journal of Heart Valve Disease , vol.7 , Issue.3 , pp. 345-354
    • Travis, B.R.1    Heinrich, R.S.2    Ensley, A.E.3    Gibson, D.E.4    Hashim, S.5    Yoganathan, A.P.6
  • 19
    • 0032465772 scopus 로고    scopus 로고
    • In vitro testing of bioprostheses: Influence of mechanical stresses and lipids on calcification
    • Deiwick M, Glasmacher B, Baba HA, et al. In vitro testing of bioprostheses: influence of mechanical stresses and lipids on calcification. Ann Thorac Surg 1998;66:206-211
    • (1998) Ann Thorac Surg , vol.66 , pp. 206-211
    • Deiwick, M.1    Glasmacher, B.2    Baba, H.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.