메뉴 건너뛰기




Volumn 37, Issue 12, 2004, Pages 2625-2640

On analytical usefulness of the recovery method

Author keywords

Atomic fluorescence spectroscopy; Blood analysis; Recovery method

Indexed keywords

ARSENIC; SELENIUM;

EID: 5344277605     PISSN: 00032719     EISSN: None     Source Type: Journal    
DOI: 10.1081/AL-200031144     Document Type: Article
Times cited : (7)

References (10)
  • 1
    • 18844439937 scopus 로고    scopus 로고
    • Harmonised guidelines for the use of recovery information in analytical measurement
    • Thompson, M.; Ellison, S.L.R.; Fajgelj, A.; Willetts, P.; Wood, R. Harmonised guidelines for the use of recovery information in analytical measurement. Pure Appl. Chem. 1999, 71, 337-348.
    • (1999) Pure Appl. Chem. , vol.71 , pp. 337-348
    • Thompson, M.1    Ellison, S.L.R.2    Fajgelj, A.3    Willetts, P.4    Wood, R.5
  • 2
    • 85025633001 scopus 로고    scopus 로고
    • Gidelines for calibration in analytical chemistry. Part 1. Fundamentals and single component calibration
    • Danzer, K.; Curie, L.A. Gidelines for calibration in analytical chemistry. Part 1. Fundamentals and single component calibration. Pure Appl. Chem. 1998, 70, 993-1014.
    • (1998) Pure Appl. Chem. , vol.70 , pp. 993-1014
    • Danzer, K.1    Curie, L.A.2
  • 3
    • 0032850224 scopus 로고    scopus 로고
    • Some remarks on the recovery method
    • Kościelniak, P. Some remarks on the recovery method. Analysis 1999, 27, 381-382.
    • (1999) Analysis , vol.27 , pp. 381-382
    • Kościelniak, P.1
  • 4
    • 0034285011 scopus 로고    scopus 로고
    • Determination of selenium in human blood specimens by electrothermal atomic absorption
    • Sabe, R.; Rubio, L.; Garcia-Beltran, L. Determination of selenium in human blood specimens by electrothermal atomic absorption. Anal. Chim. Acta 2000, 419, 121-135.
    • (2000) Anal. Chim. Acta , vol.419 , pp. 121-135
    • Sabe, R.1    Rubio, L.2    Garcia-Beltran, L.3
  • 5
    • 0344942589 scopus 로고    scopus 로고
    • A critical look at the recovery test as a way for evaluation of analytical accuracy
    • Koscielniak, P.; Wietecha, R. A critical look at the recovery test as a way for evaluation of analytical accuracy. Anal. Lett. 2003, 37, 861-870.
    • (2003) Anal. Lett. , vol.37 , pp. 861-870
    • Koscielniak, P.1    Wietecha, R.2
  • 6
    • 0019610497 scopus 로고
    • Interference by volatile nitrogen oxides and transition-metal catalysis in the preconcentration of arsenic and selenium as hydrides
    • Brown, R.M., Jr.; Fry, R.C.; Moyers, J.L.; Northway, S.J.; Denton, M.B.; Wilson, G.S. Interference by volatile nitrogen oxides and transition-metal catalysis in the preconcentration of arsenic and selenium as hydrides. Anal. Chem. 1981, 53, 1560-1566.
    • (1981) Anal. Chem. , vol.53 , pp. 1560-1566
    • Brown Jr., R.M.1    Fry, R.C.2    Moyers, J.L.3    Northway, S.J.4    Denton, M.B.5    Wilson, G.S.6
  • 7
    • 0000560141 scopus 로고
    • Elimination of nitrite interference in the determination of selenium by hydride generation
    • Cutter, G.A. Elimination of nitrite interference in the determination of selenium by hydride generation. Anal. Chim. Acta 1983, 149, 391-394.
    • (1983) Anal. Chim. Acta , vol.149 , pp. 391-394
    • Cutter, G.A.1
  • 8
    • 0000475464 scopus 로고
    • Errors in the atomic absorption determination of calcium by the standard addition method
    • Hosking, J.W.; Oliver, K.R.; Sturman, B.T. Errors in the atomic absorption determination of calcium by the standard addition method. Anal. Chem. 1979, 51, 307-310.
    • (1979) Anal. Chem. , vol.51 , pp. 307-310
    • Hosking, J.W.1    Oliver, K.R.2    Sturman, B.T.3
  • 9
    • 0003088059 scopus 로고
    • Abuse of the analyte addition technique in atomic absorption spectrometry
    • Welz, B. Abuse of the analyte addition technique in atomic absorption spectrometry. Fresenius Z. Anal. Chem. 1986, 325, 95-101.
    • (1986) Fresenius Z. Anal. Chem. , vol.325 , pp. 95-101
    • Welz, B.1
  • 10
    • 0343414539 scopus 로고    scopus 로고
    • Non-linear calibration by the standard addition method
    • Kościelniak, P. Non-linear calibration by the standard addition method. Chemom. Intell. Lab. Syst. 1999, 47, 275-287.
    • (1999) Chemom. Intell. Lab. Syst. , vol.47 , pp. 275-287
    • Kościelniak, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.