메뉴 건너뛰기




Volumn 9, Issue 4, 2008, Pages 284-287

Coronary artery aneurysm formation after drug-eluting stent implantation

Author keywords

Coronary artery aneurysm; Drug eluting stent

Indexed keywords

ABCIXIMAB;

EID: 53349176602     PISSN: 15538389     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.carrev.2008.05.004     Document Type: Article
Times cited : (13)

References (19)
  • 1
    • 53349158599 scopus 로고    scopus 로고
    • T. Mueller. Stories of survival and hope mark the one million patient milestone for the CYPHER sirolimus-eluting coronary stent. COMTEX.
    • T. Mueller. Stories of survival and hope mark the one million patient milestone for the CYPHER sirolimus-eluting coronary stent. COMTEX.
  • 3
    • 31144455965 scopus 로고    scopus 로고
    • Coronary artery aneurysm one year and five months after sirolimus-eluting stent placement
    • Abreu L., Meireles G.C., Forte A.A., Sumita M., Hyashi J., et al. Coronary artery aneurysm one year and five months after sirolimus-eluting stent placement. Arq Bras Cardiol 85 5 (2005) 340-342
    • (2005) Arq Bras Cardiol , vol.85 , Issue.5 , pp. 340-342
    • Abreu, L.1    Meireles, G.C.2    Forte, A.A.3    Sumita, M.4    Hyashi, J.5
  • 4
    • 33645878288 scopus 로고    scopus 로고
    • Coronary artery aneurysm following drug-eluting stent implantation
    • Anandaraja S., Naik N., and Talwar K. Coronary artery aneurysm following drug-eluting stent implantation. J Invasive Cardiol 18 1 (2006) E66-E67
    • (2006) J Invasive Cardiol , vol.18 , Issue.1
    • Anandaraja, S.1    Naik, N.2    Talwar, K.3
  • 6
    • 33745094127 scopus 로고    scopus 로고
    • Early aneurysm formation after drug-eluting stent implantation: an unusual life-threatening complication
    • Gupta R.K., Sapra R., and Kaul U. Early aneurysm formation after drug-eluting stent implantation: an unusual life-threatening complication. J Invasive Cardiol 18 4 (2006) E140-E142
    • (2006) J Invasive Cardiol , vol.18 , Issue.4
    • Gupta, R.K.1    Sapra, R.2    Kaul, U.3
  • 7
    • 33644676440 scopus 로고    scopus 로고
    • A case of giant aneurysm following percutaneous coronary intervention
    • Panja M., Basu S., and Mondol S. A case of giant aneurysm following percutaneous coronary intervention. Indian Heart J 57 6 (2005) 731-733
    • (2005) Indian Heart J , vol.57 , Issue.6 , pp. 731-733
    • Panja, M.1    Basu, S.2    Mondol, S.3
  • 8
    • 12344293250 scopus 로고    scopus 로고
    • Coronary aneurysm after implantation of a paclitaxel-eluting stent
    • Vik-Mo H., Wiseth R., and Hegbom K. Coronary aneurysm after implantation of a paclitaxel-eluting stent. Scand Cardiovasc J 38 6 (2004) 349-352
    • (2004) Scand Cardiovasc J , vol.38 , Issue.6 , pp. 349-352
    • Vik-Mo, H.1    Wiseth, R.2    Hegbom, K.3
  • 9
    • 0030962358 scopus 로고    scopus 로고
    • Frequency and outcome of development of coronary artery aneurysm after intracoronary stent placement and angioplasty. STRESS Trial Investigators
    • Slota P.A., Fischman D.L., Savage M.P., Rake R., Goldberg S., et al. Frequency and outcome of development of coronary artery aneurysm after intracoronary stent placement and angioplasty. STRESS Trial Investigators. Am J Cardiol 79 8 (1997) 1104-1106
    • (1997) Am J Cardiol , vol.79 , Issue.8 , pp. 1104-1106
    • Slota, P.A.1    Fischman, D.L.2    Savage, M.P.3    Rake, R.4    Goldberg, S.5
  • 10
    • 24644477492 scopus 로고    scopus 로고
    • Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial
    • Stone G.W., Ellis S.G., Cannon L., Mann J.T., Greenberg J.D., et al. Comparison of a polymer-based paclitaxel-eluting stent with a bare metal stent in patients with complex coronary artery disease: a randomized controlled trial. JAMA 294 10 (2005) 1215-1223
    • (2005) JAMA , vol.294 , Issue.10 , pp. 1215-1223
    • Stone, G.W.1    Ellis, S.G.2    Cannon, L.3    Mann, J.T.4    Greenberg, J.D.5
  • 11
    • 24944585578 scopus 로고    scopus 로고
    • Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis
    • Ako J., Morino Y., Honda Y., Hassan A., Sonoda S., et al. Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis. J Am Coll Cardiol 46 6 (2005) 1002-1005
    • (2005) J Am Coll Cardiol , vol.46 , Issue.6 , pp. 1002-1005
    • Ako, J.1    Morino, Y.2    Honda, Y.3    Hassan, A.4    Sonoda, S.5
  • 12
    • 0345526804 scopus 로고    scopus 로고
    • Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis
    • Degertekin M., Serruys P.W., Tanabe K., Lee C.H., Sousa J.E., et al. Long-term follow-up of incomplete stent apposition in patients who received sirolimus-eluting stent for de novo coronary lesions: an intravascular ultrasound analysis. Circulation 108 22 (2003) 2747-2750
    • (2003) Circulation , vol.108 , Issue.22 , pp. 2747-2750
    • Degertekin, M.1    Serruys, P.W.2    Tanabe, K.3    Lee, C.H.4    Sousa, J.E.5
  • 13
    • 0034597889 scopus 로고    scopus 로고
    • Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
    • Koster R., Vieluf D., Kiehn M., Sommerhauer M., Kahler J., et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 356 9245 (2000) 1895-1897
    • (2000) Lancet , vol.356 , Issue.9245 , pp. 1895-1897
    • Koster, R.1    Vieluf, D.2    Kiehn, M.3    Sommerhauer, M.4    Kahler, J.5
  • 14
    • 0344211507 scopus 로고    scopus 로고
    • Evaluation of metal allergies in patients with coronary stents
    • Hillen U., Haude M., Erbel R., and Goos M. Evaluation of metal allergies in patients with coronary stents. Contact Dermatitis 47 6 (2002) 353-356
    • (2002) Contact Dermatitis , vol.47 , Issue.6 , pp. 353-356
    • Hillen, U.1    Haude, M.2    Erbel, R.3    Goos, M.4
  • 15
    • 0025934137 scopus 로고
    • Coronary aneurysms after stent placement: a suggestion of altered vessel wall healing in the presence of anti-inflammatory agents
    • Rab S.T., King III S.B., Roubin G.S., Carlin S., Hearn J.A., et al. Coronary aneurysms after stent placement: a suggestion of altered vessel wall healing in the presence of anti-inflammatory agents. J Am Coll Cardiol 18 6 (1991) 1524-1528
    • (1991) J Am Coll Cardiol , vol.18 , Issue.6 , pp. 1524-1528
    • Rab, S.T.1    King III, S.B.2    Roubin, G.S.3    Carlin, S.4    Hearn, J.A.5
  • 16
    • 0004122190 scopus 로고    scopus 로고
    • Elsevier, Inc, St. Louis (Mo)
    • Mosby's Drug Consult (2004), Elsevier, Inc, St. Louis (Mo)
    • (2004) Mosby's Drug Consult
  • 17
    • 0029761378 scopus 로고    scopus 로고
    • Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
    • Van der Giessen W.J., Lincoff A.M., Schwartz R.S., Van Beusekom H.S., Serruys P., et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 94 7 (1996) 1690-1697
    • (1996) Circulation , vol.94 , Issue.7 , pp. 1690-1697
    • Van der Giessen, W.J.1    Lincoff, A.M.2    Schwartz, R.S.3    Van Beusekom, H.S.4    Serruys, P.5
  • 18
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?
    • Virmani R., Guagliumi G., Farb A., Grieco N., Motta T., et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?. Circulation 109 6 (2004) 701-705
    • (2004) Circulation , vol.109 , Issue.6 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3    Grieco, N.4    Motta, T.5
  • 19
    • 29344432871 scopus 로고    scopus 로고
    • Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project
    • Nebeker J.R., Virmani R., Bennett C.L., Hoffman J.M., Samore M.H., et al. Hypersensitivity cases associated with drug-eluting coronary stents: a review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project. J Am Coll Cardiol 47 1 (2006) 175-181
    • (2006) J Am Coll Cardiol , vol.47 , Issue.1 , pp. 175-181
    • Nebeker, J.R.1    Virmani, R.2    Bennett, C.L.3    Hoffman, J.M.4    Samore, M.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.