Volumn 17 IFMBE, Issue , 2007, Pages 715-718

Verification of physical models used for root canal measurement by impedance comparison

Author keywords

Electrical equivalent circuit of a tooth; Electronic apex locator; Endodontics; Root canal measurement; Tooth model verification

Indexed keywords

ELECTRIC IMPEDANCE; ELECTRIC IMPEDANCE MEASUREMENT; ELECTRIC IMPEDANCE TOMOGRAPHY; EQUIVALENT CIRCUITS; PETROLEUM RESERVOIR EVALUATION; WELL TESTING;

EID: 53349167170     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-540-73841-1_184     Document Type: Conference Paper
Times cited : (9)

References (13)
  • 1
    • 3042743477 scopus 로고    scopus 로고
    • Electronic apex locators
    • Gordon MP, Chandler NP. (2004) Electronic apex locators. Int Endod J 7(7): 425-7
    • (2004) Int Endod J , vol.7 , Issue.7 , pp. 425-427
    • Gordon, M.P.1    Chandler, N.P.2
  • 2
    • 0028402339 scopus 로고
    • New electronic canal measuring device based on the ratio method
    • Kobayashi C, Suda H. (1994): 'New electronic canal measuring device based on the ratio method', J. Endodon., 20, pp. 111-4
    • (1994) J. Endodon. , vol.20 , pp. 111-114
    • Kobayashi, C.1    Suda, H.2
  • 3
    • 0036484408 scopus 로고    scopus 로고
    • Accuracy of a new apex locator: An in vitro study
    • Kaufman AY, Keila S, Yoshpe M. (2002) Accuracy of a new apex locator: an in vitro study. Int Endod J. 35:186-92
    • (2002) Int Endod J. , vol.35 , pp. 186-192
    • Kaufman, A.Y.1    Keila, S.2    Yoshpe, M.3
  • 4
    • 0035292483 scopus 로고    scopus 로고
    • An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants
    • Jenkins JA, Walker War, et al. (2001) An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants. J Endod. 27:209-11
    • (2001) J Endod. , vol.27 , pp. 209-211
    • Jenkins, J.A.1    War, W.2
  • 5
    • 0027693242 scopus 로고
    • A simplified model to demonstrate the operation of electronic root canal measuring devices
    • Donnelly JC (1993) A simplified model to demonstrate the operation of electronic root canal measuring devices, J Endodon 19: 579-80.
    • (1993) J Endodon , vol.19 , pp. 579-580
    • Donnelly, J.C.1
  • 6
    • 78649964525 scopus 로고    scopus 로고
    • A comparative evaluation of the accuracy of third generation electronic apex locator (Root ZX) in presence of various intracanal irrigants
    • Goel Y, et al. (2006) A comparative evaluation of the accuracy of third generation electronic apex locator (Root ZX) in presence of various intracanal irrigants, Endodontology, Pub. Ind. Endodon. Soc. 18/1: 28-33
    • (2006) Endodontology, Pub. Ind. Endodon. Soc. , vol.18 , Issue.1 , pp. 28-33
    • Goel, Y.1
  • 7
    • 33645096500 scopus 로고    scopus 로고
    • A simple mounting model for consistent determination of the accuracy and repeatability of apex locators
    • A. ElAyouti & C. Löst (2006) A simple mounting model for consistent determination of the accuracy and repeatability of apex locators. Int Endod J 39: 108-112
    • (2006) Int Endod J , vol.39 , pp. 108-112
    • ElAyouti, A.1    Löst, C.2
  • 8
    • 0031989863 scopus 로고    scopus 로고
    • In vitro evaluation of the reliability of the Endex electronic apex locator
    • Ounsi HF, Haddad G. (1998) In vitro evaluation of the reliability of the Endex electronic apex locator, Jour. of Endodon, 4:120-1
    • (1998) Jour. of Endodon , vol.4 , pp. 120-121
    • Ounsi, H.F.1    Haddad, G.2
  • 11
    • 0031268020 scopus 로고    scopus 로고
    • Reliability of different electronic apex locators to detect root perforations in vitro
    • Kaufman AY, et al. (1997) Reliability of different electronic apex locators to detect root perforations in vitro, Int.Endodon.J.30, 403-407
    • (1997) Int.Endodon.J. , vol.30 , pp. 403-407
    • Kaufman, A.Y.1
  • 12
    • 0036484408 scopus 로고    scopus 로고
    • Accuracy of new apex locator: An in vitro study
    • Kaufman AY, Keila S, Yoshpe M (2002) Accuracy of new apex locator: an in vitro study, Int. Endodon. J. 35, 186-192
    • (2002) Int. Endodon. J. , vol.35 , pp. 186-192
    • Kaufman, A.Y.1    Keila, S.2    Yoshpe, M.3
  • 13
    • 0033088060 scopus 로고    scopus 로고
    • Comparison of measurements obtained with hand files or the Canal Leader attached to electronic apex locators: An in vitro study
    • Steffen H, Splieth CH, Behr K (1999) Comparison of measurements obtained with hand files or the Canal Leader attached to electronic apex locators: an in vitro study, Int. Endodon. J. 32, 103-107
    • (1999) Int. Endodon. J. , vol.32 , pp. 103-107
    • Steffen, H.1    Splieth, C.H.2    Behr, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.