Development of a fully automated soap flowmeter for micro flow measurements

Author keywords

Bubble maker; Foam film; Gas flow measurement; Micro flow; Soap bubble; Soap flowmeter

Indexed keywords

AERODYNAMICS; AUTOMATION; FLOW MEASUREMENT; FLOW MEASURING INSTRUMENTS; FLOW OF GASES; FLOW RATE; GAS DYNAMICS; TIME MEASUREMENT; TUBES (COMPONENTS);

EID: 53349164118     PISSN: 09555986     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.flowmeasinst.2008.08.001     Document Type: Article
Times cited : (12)

References (19)
  • 1
    • 0001661223 scopus 로고
    • The accuracy of the bubble meter method for gas flow measurements
    • Levy A. The accuracy of the bubble meter method for gas flow measurements. J Sci Instrum 41 (1964) 449-453
    • (1964) J Sci Instrum , vol.41 , pp. 449-453
    • Levy, A.1
  • 2
    • 0344108078 scopus 로고
    • Über den Durchgang der Gase durch Flüssigkeitslamellen
    • Exner F. Über den Durchgang der Gase durch Flüssigkeitslamellen. Pogg Ann Phys Chem 231 (1875) 321
    • (1875) Pogg Ann Phys Chem , vol.231 , pp. 321
    • Exner, F.1
  • 3
    • 6444230514 scopus 로고
    • Two designs of flow-meter, and a method of calibration
    • Barr G. Two designs of flow-meter, and a method of calibration. J Sci Instrum 11 (1934) 321-324
    • (1934) J Sci Instrum , vol.11 , pp. 321-324
    • Barr, G.1
  • 4
    • 0018004469 scopus 로고
    • Reference standards for gas flow measurement
    • Brian T.J.S. Reference standards for gas flow measurement. Meas Control 11 August (1978) 283-288
    • (1978) Meas Control , vol.11 , Issue.August , pp. 283-288
    • Brian, T.J.S.1
  • 5
    • 0022732499 scopus 로고
    • The calibration of flowmeters
    • [special issue]
    • Pursley W.C. The calibration of flowmeters. Meas Control 19 5 (1986) 37-45 [special issue]
    • (1986) Meas Control , vol.19 , Issue.5 , pp. 37-45
    • Pursley, W.C.1
  • 6
    • 0018078462 scopus 로고
    • Accuracy of gas flowmeters determined by the bubble meter method
    • Waaben J., Stokke D.B., and Brinkløv M.M. Accuracy of gas flowmeters determined by the bubble meter method. Br J Anaesth 50 (1978) 1251-1255
    • (1978) Br J Anaesth , vol.50 , pp. 1251-1255
    • Waaben, J.1    Stokke, D.B.2    Brinkløv, M.M.3
  • 7
    • 0028450559 scopus 로고
    • Soap film drainage: Theory and experiment
    • Barigou M., and Davidson J.F. Soap film drainage: Theory and experiment. Chem Eng Sci 49 11 (1994) 1807-1819
    • (1994) Chem Eng Sci , vol.49 , Issue.11 , pp. 1807-1819
    • Barigou, M.1    Davidson, J.F.2
  • 8
    • 0042020109 scopus 로고    scopus 로고
    • Numerical simulation of the steady movement of a foam film in a tube
    • Part A
    • Barigou M., Deshpande N.S., and Wiggers F.N. Numerical simulation of the steady movement of a foam film in a tube. Trans IChemE 81 July (2003) 623-630 Part A
    • (2003) Trans IChemE , vol.81 , Issue.July , pp. 623-630
    • Barigou, M.1    Deshpande, N.S.2    Wiggers, F.N.3
  • 9
    • 85008732114 scopus 로고
    • Part I-Inaccuracy of the moving bubble flowmeter in the low flow rate region
    • Czubryt J.J., and Gesser H.D. Part I-Inaccuracy of the moving bubble flowmeter in the low flow rate region. J Gas Chromat 6 (1968) 528-530
    • (1968) J Gas Chromat , vol.6 , pp. 528-530
    • Czubryt, J.J.1    Gesser, H.D.2
  • 10
    • 6444228697 scopus 로고    scopus 로고
    • Diffusion problems of soap-film flowmeter when measuring very low-rate gas flow
    • Guo J., and Heslop M.J. Diffusion problems of soap-film flowmeter when measuring very low-rate gas flow. Flow Meas Instrum 15 (2004) 331-334
    • (2004) Flow Meas Instrum , vol.15 , pp. 331-334
    • Guo, J.1    Heslop, M.J.2
  • 13
    • 0034233287 scopus 로고    scopus 로고
    • The flow of foam in vertical tubes
    • Part A
    • Wiggers F.N., Deshpande N.S., and Barigou M. The flow of foam in vertical tubes. Trans IChemE 78 July (2000) 773-778 Part A
    • (2000) Trans IChemE , vol.78 , Issue.July , pp. 773-778
    • Wiggers, F.N.1    Deshpande, N.S.2    Barigou, M.3
  • 14
    • 0027628335 scopus 로고
    • The fluid mechanics of the soap film meter
    • Barigou M., and Davidson J.F. The fluid mechanics of the soap film meter. Chem Eng Sci 48 14 (1993) 2587-2597
    • (1993) Chem Eng Sci , vol.48 , Issue.14 , pp. 2587-2597
    • Barigou, M.1    Davidson, J.F.2
  • 15
    • 6444219562 scopus 로고
    • Comments on the pressure produced by a soap film meter
    • Heslop M.J., Mason G., and Provatas A. Comments on the pressure produced by a soap film meter. Chem Eng Sci 50 15 (1995) 2495-2497
    • (1995) Chem Eng Sci , vol.50 , Issue.15 , pp. 2495-2497
    • Heslop, M.J.1    Mason, G.2    Provatas, A.3
  • 17
    • 36149056169 scopus 로고
    • Photoelectric timer for the bubble meter method of gas flow measurement
    • Hunter J.J. Photoelectric timer for the bubble meter method of gas flow measurement. J Sci Instrum 42 (1965) 175
    • (1965) J Sci Instrum , vol.42 , pp. 175
    • Hunter, J.J.1
  • 18
    • 0029138371 scopus 로고
    • A time-integration-based measurement circuit for a soap bubble flow-meter using optical fibre sensors
    • Arenas A., Victoria L., and Ibaňez J.A. A time-integration-based measurement circuit for a soap bubble flow-meter using optical fibre sensors. Mass Sci Technol 6 (1995) 435-436
    • (1995) Mass Sci Technol , vol.6 , pp. 435-436
    • Arenas, A.1    Victoria, L.2    Ibaňez, J.A.3
  • 19
    • 0000589841 scopus 로고
    • Static menisci in a vertical right circular cylinder
    • Part 3
    • Concus P. Static menisci in a vertical right circular cylinder. J Fluid Mech 34 (1968) 481-495 Part 3
    • (1968) J Fluid Mech , vol.34 , pp. 481-495
    • Concus, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.