메뉴 건너뛰기




Volumn 36, Issue 9, 2008, Pages 2558-2561

Efficacy of three different valve systems of needle-free closed connectors in avoiding access of microorganisms to endovascular catheters after incorrect handling

Author keywords

Catheter colonization; Catheter infection; Disinfectable connector; Needle less connector; Nosocomial infection; Prophylaxis

Indexed keywords

ARTICLE; BACTERIAL COLONIZATION; BACTERIUM CONTAMINATION; BACTERIUM CULTURE; BLOOD CULTURE; CONTROLLED STUDY; DISINFECTION; INTRAVASCULAR CATHETER; INTRAVENOUS CATHETER; NEEDLESTICK INJURY; PRIORITY JOURNAL; STAPHYLOCOCCUS EPIDERMIDIS; CATHETERIZATION; EQUIPMENT; EQUIPMENT DESIGN; INDWELLING CATHETER; INSTRUMENTATION; MICROBIOLOGY;

EID: 53049106538     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0b013e318183effb     Document Type: Article
Times cited : (26)

References (17)
  • 1
    • 85031347956 scopus 로고    scopus 로고
    • Benson JS: FDA alert: Needlestick and other risks from hypodermic needles on secondary LV administration sets-Piggyback and intermittent I.V. Rockville, MD: US Department of Health and Human Services, Public Health Service, 1992
    • Benson JS: FDA alert: Needlestick and other risks from hypodermic needles on secondary LV administration sets-Piggyback and intermittent I.V. Rockville, MD: US Department of Health and Human Services, Public Health Service, 1992
  • 2
    • 0022348088 scopus 로고
    • Catheter sepsis: The clue is the hub
    • Sitges-Serra A, Linares J, Garau J: Catheter sepsis: The clue is the hub. Surgery 1985; 97: 355-357
    • (1985) Surgery , vol.97 , pp. 355-357
    • Sitges-Serra, A.1    Linares, J.2    Garau, J.3
  • 3
    • 0027182766 scopus 로고
    • Ultrastructural analysis of indwelling catheters: A quantitative relationship between luminal colonization and duration of placement
    • Raad I, Costerton JW, Sabharwal U, et al: Ultrastructural analysis of indwelling catheters: A quantitative relationship between luminal colonization and duration of placement. J Infect Dis 1993; 168:400-407
    • (1993) J Infect Dis , vol.168 , pp. 400-407
    • Raad, I.1    Costerton, J.W.2    Sabharwal, U.3
  • 4
    • 0030969903 scopus 로고    scopus 로고
    • Serial surveillance cultures of skin and catheter hub specimens from critically ill patients with central venous catheters: Molecular epidemiology of infection and implications for clinical management and research
    • Atela I, Coll P, Rello J, et al: Serial surveillance cultures of skin and catheter hub specimens from critically ill patients with central venous catheters: Molecular epidemiology of infection and implications for clinical management and research. J Clin Microbiol 1997; 35:1784 -1790
    • (1997) J Clin Microbiol , vol.35 , pp. 1784-1790
    • Atela, I.1    Coll, P.2    Rello, J.3
  • 5
    • 0031085196 scopus 로고    scopus 로고
    • The effectiveness of a needleless intravenous connection system: An assessment by injury rate and user satisfaction
    • Lawrence LW, Delclos GL, Felknor SA, et al: The effectiveness of a needleless intravenous connection system: An assessment by injury rate and user satisfaction. Infect Control Hosp Epidemiol 1997; 18:175-182
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 175-182
    • Lawrence, L.W.1    Delclos, G.L.2    Felknor, S.A.3
  • 6
    • 0032175189 scopus 로고    scopus 로고
    • Line-associated bloodstream infections in pediat-ric intensive-care-unit patients associated with a needleless device and intermittent intravenous therapy
    • McDonald LC, Banerjee SN, Jarvis WR: Line-associated bloodstream infections in pediat-ric intensive-care-unit patients associated with a needleless device and intermittent intravenous therapy. Infect Control Hosp Epidemiol 1998; 19:772-777
    • (1998) Infect Control Hosp Epidemiol , vol.19 , pp. 772-777
    • McDonald, L.C.1    Banerjee, S.N.2    Jarvis, W.R.3
  • 7
    • 0031600535 scopus 로고    scopus 로고
    • Increased bloodstream infection rates in surgical patients associated with variation from recommended use and care following implementation of a needleless device
    • Cookson ST, Ihrig M, O'Mara EM, et al: Increased bloodstream infection rates in surgical patients associated with variation from recommended use and care following implementation of a needleless device. Infect Control Hosp Epidemiol 1998; 19:23-27
    • (1998) Infect Control Hosp Epidemiol , vol.19 , pp. 23-27
    • Cookson, S.T.1    Ihrig, M.2    O'Mara, E.M.3
  • 8
    • 0031827824 scopus 로고    scopus 로고
    • Comparison of the microbial barrier properties of a needleless and a conventional needle-based intravenous access system
    • Luebcke MA, Arduino MJ, Duda DL, et al: Comparison of the microbial barrier properties of a needleless and a conventional needle-based intravenous access system. Am J Infect Control 1998; 26:437-441
    • (1998) Am J Infect Control , vol.26 , pp. 437-441
    • Luebcke, M.A.1    Arduino, M.J.2    Duda, D.L.3
  • 9
    • 0348014398 scopus 로고    scopus 로고
    • Resistance to the migration of microorganisms of a needle-free disinfectable connector
    • Yébenes JC, Martinez R, Serra-Prat M, et al: Resistance to the migration of microorganisms of a needle-free disinfectable connector. Am J Infect Control 2003; 31: 462-464
    • (2003) Am J Infect Control , vol.31 , pp. 462-464
    • Yébenes, J.C.1    Martinez, R.2    Serra-Prat, M.3
  • 10
    • 3342983315 scopus 로고    scopus 로고
    • Experimental study on the safety of a new connecting device
    • Trautmann M, Moosbauer S, Schmitz FJ: Experimental study on the safety of a new connecting device. Am J Infect Control 2004; 32:296-300
    • (2004) Am J Infect Control , vol.32 , pp. 296-300
    • Trautmann, M.1    Moosbauer, S.2    Schmitz, F.J.3
  • 11
    • 3342877647 scopus 로고    scopus 로고
    • Prevention of catheter-related bloodstream infection in critically ill patients using a disinfectable, needle-free connector: A randomized controlled trial
    • Yébenes JC, Vidaur L, Serra-Prat M, et al: Prevention of catheter-related bloodstream infection in critically ill patients using a disinfectable, needle-free connector: A randomized controlled trial. Am J Infect Control 2004; 32:291-295
    • (2004) Am J Infect Control , vol.32 , pp. 291-295
    • Yébenes, J.C.1    Vidaur, L.2    Serra-Prat, M.3
  • 12
    • 0142181296 scopus 로고    scopus 로고
    • A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: A prospective randomized study
    • Bouza E, Munoz P, López-Rodriguez J, et al: A needleless closed system device (CLAVE) protects from intravascular catheter tip and hub colonization: A prospective randomized study. J Hosp Infect 2003; 54:279-287
    • (2003) J Hosp Infect , vol.54 , pp. 279-287
    • Bouza, E.1    Munoz, P.2    López-Rodriguez, J.3
  • 13
    • 33646448759 scopus 로고    scopus 로고
    • Increased catheter-related bloodstream infection rates after the introduction of a new mechanical valve intravenous access port
    • Maragakis LL, Bradley KL, Song X, et al: Increased catheter-related bloodstream infection rates after the introduction of a new mechanical valve intravenous access port. Infect Control Hosp Epidemiol 2006; 27: 67-70
    • (2006) Infect Control Hosp Epidemiol , vol.27 , pp. 67-70
    • Maragakis, L.L.1    Bradley, K.L.2    Song, X.3
  • 14
    • 0021959713 scopus 로고
    • Handwashing and skin: Physiologic and bacteriologic aspects
    • Larson E: Handwashing and skin: physiologic and bacteriologic aspects. Infect Control 1985; 6:14-23
    • (1985) Infect Control , vol.6 , pp. 14-23
    • Larson, E.1
  • 15
    • 0142150298 scopus 로고    scopus 로고
    • A randomized, prospective clinical trial to assess the potential infection risk associated with the PosiFlow needleless connector
    • Casey AL, Worthington T, Lambert PA, et al: A randomized, prospective clinical trial to assess the potential infection risk associated with the PosiFlow needleless connector. J Hosp Infect 2003; 54:288-293
    • (2003) J Hosp Infect , vol.54 , pp. 288-293
    • Casey, A.L.1    Worthington, T.2    Lambert, P.A.3
  • 16
    • 0033949078 scopus 로고    scopus 로고
    • A prospective clinical study to investigate the microbial contamination of a needleless connector
    • Seymour VM, Dhallu TS, Moss HA, et al: A prospective clinical study to investigate the microbial contamination of a needleless connector. J Hosp Infect 200; 45:165-168
    • J Hosp Infect , vol.200 , Issue.45 , pp. 165-168
    • Seymour, V.M.1    Dhallu, T.S.2    Moss, H.A.3
  • 17
    • 0036916816 scopus 로고    scopus 로고
    • Guidelines for the prevention of intravascular catheter-related infections
    • O'Grady NP, Alexander M, Dellinger EP, et al: Guidelines for the prevention of intravascular catheter-related infections. Infect Control Hosp Epidemiol 2002; 23:759-769
    • (2002) Infect Control Hosp Epidemiol , vol.23 , pp. 759-769
    • O'Grady, N.P.1    Alexander, M.2    Dellinger, E.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.