메뉴 건너뛰기




Volumn 5, Issue 10, 2008, Pages 1403-1410

Real-time integration of intracardiac echocardiography and multislice computed tomography to guide radiofrequency catheter ablation for atrial fibrillation

Author keywords

Atrial fibrillation; Catheter ablation; Intracardiac echocardiography; Mapping; Multi slice computed tomography

Indexed keywords

ADULT; AGED; ARTICLE; CATHETER ABLATION; CLINICAL ARTICLE; ECHOCARDIOGRAPHY; FEASIBILITY STUDY; FEMALE; HEART ATRIUM FIBRILLATION; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE RECONSTRUCTION; INTRACARDIAC ECHOCARDIOGRAPHY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RADIOFREQUENCY ABLATION; REAL TIME ECHOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 53049085952     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2008.07.020     Document Type: Article
Times cited : (46)

References (19)
  • 1
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • Haissaguerre M., Jais P., Shah D.C., et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 339 (1998) 659-666
    • (1998) N Engl J Med , vol.339 , pp. 659-666
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3
  • 2
    • 34249814933 scopus 로고    scopus 로고
    • HRS/EHRA/ECAS expert consensus atatement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation
    • Calkins H., Brugada J., Packer D.L., et al. HRS/EHRA/ECAS expert consensus atatement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up. A report of the Heart Rhythm Society (HRS) Task Force on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 4 (2007) 816-861
    • (2007) Heart Rhythm , vol.4 , pp. 816-861
    • Calkins, H.1    Brugada, J.2    Packer, D.L.3
  • 3
    • 1942536466 scopus 로고    scopus 로고
    • Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation
    • Mansour M., Holmvang G., Sosnovik D., et al. Assessment of pulmonary vein anatomic variability by magnetic resonance imaging: implications for catheter ablation techniques for atrial fibrillation. J Cardiovasc Electrophysiol 15 (2004) 387-393
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 387-393
    • Mansour, M.1    Holmvang, G.2    Sosnovik, D.3
  • 4
    • 13244279615 scopus 로고    scopus 로고
    • Multislice computed tomography versus intracardiac echocardiography to evaluate the pulmonary veins before radiofrequency catheter ablation of atrial fibrillation: a head-to-head comparison
    • Jongbloed M.R., Bax J.J., Lamb H.J., et al. Multislice computed tomography versus intracardiac echocardiography to evaluate the pulmonary veins before radiofrequency catheter ablation of atrial fibrillation: a head-to-head comparison. J Am Coll Cardiol 45 (2005) 343-350
    • (2005) J Am Coll Cardiol , vol.45 , pp. 343-350
    • Jongbloed, M.R.1    Bax, J.J.2    Lamb, H.J.3
  • 5
    • 26944436282 scopus 로고    scopus 로고
    • Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures
    • Tops L.F., Bax J.J., Zeppenfeld K., et al. Fusion of multislice computed tomography imaging with three-dimensional electroanatomic mapping to guide radiofrequency catheter ablation procedures. Heart Rhythm 2 (2005) 1076-1081
    • (2005) Heart Rhythm , vol.2 , pp. 1076-1081
    • Tops, L.F.1    Bax, J.J.2    Zeppenfeld, K.3
  • 6
    • 33748748786 scopus 로고    scopus 로고
    • The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation
    • Kistler P.M., Rajappan K., Jahngir M., et al. The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 1093-1101
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 1093-1101
    • Kistler, P.M.1    Rajappan, K.2    Jahngir, M.3
  • 7
    • 33846990846 scopus 로고    scopus 로고
    • Intracardiac echo-guided image integration: optimizing strategies for registration
    • Fahmy T.S., Mlcochova H., Wazni O.M., et al. Intracardiac echo-guided image integration: optimizing strategies for registration. J Cardiovasc Electrophysiol 18 (2007) 276-282
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 276-282
    • Fahmy, T.S.1    Mlcochova, H.2    Wazni, O.M.3
  • 8
    • 1342329985 scopus 로고    scopus 로고
    • Variations in pulmonary venous drainage to the left atrium: implications for radiofrequency ablation
    • Marom E.M., Herndon J.E., Kim Y.H., et al. Variations in pulmonary venous drainage to the left atrium: implications for radiofrequency ablation. Radiology 230 (2004) 824-829
    • (2004) Radiology , vol.230 , pp. 824-829
    • Marom, E.M.1    Herndon, J.E.2    Kim, Y.H.3
  • 9
    • 33746833635 scopus 로고    scopus 로고
    • ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines
    • (Writing Committee to Revise the 2001 Guidelines for the Management of Patients with Atrial Fibrillation)
    • Fuster V., Ryden L.E., Cannom D.S., et al. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines. (Writing Committee to Revise the 2001 Guidelines for the Management of Patients with Atrial Fibrillation). J Am Coll Cardiol 48 (2006) 854-906
    • (2006) J Am Coll Cardiol , vol.48 , pp. 854-906
    • Fuster, V.1    Ryden, L.E.2    Cannom, D.S.3
  • 10
    • 40349108808 scopus 로고    scopus 로고
    • First human experience with real-time integration of intracardiac echocardiography and 3D electroanatomical imaging to guide right free wall accessory pathway ablation
    • Khaykin Y., Klemm O., and Verma A. First human experience with real-time integration of intracardiac echocardiography and 3D electroanatomical imaging to guide right free wall accessory pathway ablation. Europace 10 (2008) 116-117
    • (2008) Europace , vol.10 , pp. 116-117
    • Khaykin, Y.1    Klemm, O.2    Verma, A.3
  • 11
    • 53049085427 scopus 로고    scopus 로고
    • Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system
    • Okumura Y., Henz B.D., Johnson S.B., et al. Three-dimensional ultrasound for image-guided mapping and intervention: methods, quantitative validation, and clinical feasibility of a novel multimodality image mapping system. Circ Arrhyth Electrophysiol 1 (2008) 110-119
    • (2008) Circ Arrhyth Electrophysiol , vol.1 , pp. 110-119
    • Okumura, Y.1    Henz, B.D.2    Johnson, S.B.3
  • 12
    • 53049096598 scopus 로고    scopus 로고
    • Khaykin Y, Klemm O, Whaley B, et al. First human experience with real time integration of intracardiac echocardiography and 3D electroanatomical imaging to guide pulmonary vein antrum isolation. J Am Coll Cardiol 51:A1-A34.
    • Khaykin Y, Klemm O, Whaley B, et al. First human experience with real time integration of intracardiac echocardiography and 3D electroanatomical imaging to guide pulmonary vein antrum isolation. J Am Coll Cardiol 51:A1-A34.
  • 13
    • 53049102519 scopus 로고    scopus 로고
    • Intracardiac ECHO integration with three dimensional mapping: role in AF ablation
    • Khaykin Y., Skanes A., Wulffhart Z., et al. Intracardiac ECHO integration with three dimensional mapping: role in AF ablation. JAFIB 1 (2008) 74-79
    • (2008) JAFIB , vol.1 , pp. 74-79
    • Khaykin, Y.1    Skanes, A.2    Wulffhart, Z.3
  • 14
    • 38449105195 scopus 로고    scopus 로고
    • Multi-modality imaging to assess left atrial size, anatomy and function
    • Tops L.F., van der Wall E.E., Schalij M.J., et al. Multi-modality imaging to assess left atrial size, anatomy and function. Heart 93 (2007) 1461-1470
    • (2007) Heart , vol.93 , pp. 1461-1470
    • Tops, L.F.1    van der Wall, E.E.2    Schalij, M.J.3
  • 15
    • 33645010220 scopus 로고    scopus 로고
    • Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations
    • Dong J., Calkins H., Solomon S.B., et al. Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations. Circulation 113 (2006) 186-194
    • (2006) Circulation , vol.113 , pp. 186-194
    • Dong, J.1    Calkins, H.2    Solomon, S.B.3
  • 16
    • 33645279547 scopus 로고    scopus 로고
    • Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation
    • Kistler P.M., Earley M.J., Harris S., et al. Validation of three-dimensional cardiac image integration: use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 17 (2006) 341-348
    • (2006) J Cardiovasc Electrophysiol , vol.17 , pp. 341-348
    • Kistler, P.M.1    Earley, M.J.2    Harris, S.3
  • 17
    • 33947198922 scopus 로고    scopus 로고
    • Accuracy of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping for real-time guided radiofrequency ablation of left atrial fibrillation-influence of heart rhythm and radiofrequency lesions
    • Martinek M., Nesser H.J., Aichinger J., et al. Accuracy of integration of multislice computed tomography imaging into three-dimensional electroanatomic mapping for real-time guided radiofrequency ablation of left atrial fibrillation-influence of heart rhythm and radiofrequency lesions. J Interv Card Electrophysiol 17 (2006) 85-92
    • (2006) J Interv Card Electrophysiol , vol.17 , pp. 85-92
    • Martinek, M.1    Nesser, H.J.2    Aichinger, J.3
  • 18
    • 36148966625 scopus 로고    scopus 로고
    • Impact of heart rhythm status on registration accuracy of the left atrium for catheter ablation of atrial fibrillation
    • Dong J., Dalal D., Scherr D., et al. Impact of heart rhythm status on registration accuracy of the left atrium for catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 18 (2007) 1269-1276
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 1269-1276
    • Dong, J.1    Dalal, D.2    Scherr, D.3
  • 19
    • 0347063910 scopus 로고    scopus 로고
    • A comparison of pulmonary vein ostial anatomy by computerized tomography, echocardiography, and venography in patients with atrial fibrillation having radiofrequency catheter ablation
    • Wood M.A., Wittkamp M., Henry D., et al. A comparison of pulmonary vein ostial anatomy by computerized tomography, echocardiography, and venography in patients with atrial fibrillation having radiofrequency catheter ablation. Am J Cardiol 93 (2004) 49-53
    • (2004) Am J Cardiol , vol.93 , pp. 49-53
    • Wood, M.A.1    Wittkamp, M.2    Henry, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.