-
1
-
-
0041920851
-
-
J. Neurosurg..
-
Z. A. Smith, A. A. F. De Salles, L. Frighetto, B. Goss, S. P. Lee, M. Selch, R. E. Wallace, C. Cabatan-Awang, and T. Solberg, " Dedicated linear accelerator radiosurgery for the treatment of trigeminal neuralgia.," J. Neurosurg. 99, 511-516 (2003).
-
(2003)
Dedicated Linear Accelerator Radiosurgery for the Treatment of Trigeminal Neuralgia
, vol.99
, pp. 511-516
-
-
Smith, Z.A.1
De Salles, A.A.F.2
Frighetto, L.3
Goss, B.4
Lee, S.P.5
Selch, M.6
Wallace, R.E.7
Cabatan-Awang, C.8
Solberg, T.9
-
3
-
-
0025016515
-
-
Med. Phys..
-
B. E. Bjängard, J.-S. Tsai, and R. K. Rice, " Doses on the central axes of narrow 6-MV x-ray beams.," Med. Phys. 17, 794-799 (1990).
-
(1990)
Doses on the Central Axes of Narrow 6-MV X-ray Beams
, vol.17
, pp. 794-799
-
-
Bjängard, B.E.1
Tsai, J.-S.2
Rice, R.K.3
-
5
-
-
0036703573
-
-
Med. Phys..
-
F.-F. Yin, J. Zhu, H. Yan, H. Gaun, R. Hammoud, S. Ryu, and J. H. Kim, " Dosimetric characteristics of Novalis shaped beam surgery unit.," Med. Phys. 29, 1729-1738 (2002).
-
(2002)
Dosimetric Characteristics of Novalis Shaped Beam Surgery Unit
, vol.29
, pp. 1729-1738
-
-
Yin, F.-F.1
Zhu, J.2
Yan, H.3
Gaun, H.4
Hammoud, R.5
Ryu, S.6
Kim, J.H.7
-
6
-
-
33646493919
-
-
Phys. Med. Biol..
-
G. X. Ding, D. M. Duggan, and C. W. Coffey, " Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods.," Phys. Med. Biol. 51, 2549-2566 (2006).
-
(2006)
Commissioning Stereotactic Radiosurgery Beams Using Both Experimental and Theoretical Methods
, vol.51
, pp. 2549-2566
-
-
Ding, G.X.1
Duggan, D.M.2
Coffey, C.W.3
-
7
-
-
34547454939
-
-
Med. Phys..
-
C. Cheng, S. H. Cho, M. Taylor, and I. J. Das, " Determination of zero-field size percent depth doses and tissue maximum ratios for stereotactic radiosurgery and IMRT dosimetry: Comparison between experimental measurements and Monte Carlo simulation.," Med. Phys. 34, 3149-3157 (2007).
-
(2007)
Determination of Zero-field Size Percent Depth Doses and Tissue Maximum Ratios for Stereotactic Radiosurgery and IMRT Dosimetry: Comparison between Experimental Measurements and Monte Carlo Simulation
, vol.34
, pp. 3149-3157
-
-
Cheng, C.1
Cho, S.H.2
Taylor, M.3
Das, I.J.4
-
8
-
-
77957699326
-
-
Med. Phys..
-
S. Li, P. Medin, S. Pillai, and T. Solberg, " Analysis of photon beam data from multiple institutions: an argument for reference data.," Med. Phys. 33, 1991 (2006).
-
(2006)
Analysis of Photon Beam Data from Multiple Institutions: An Argument for Reference Data
, vol.33
, pp. 1991
-
-
Li, S.1
Medin, P.2
Pillai, S.3
Solberg, T.4
-
9
-
-
37549052531
-
-
Med. Phys..
-
I. J. Das, G. X. Ding, and A. Ahnesjö, " Small fields: Nonequilibrium radiation dosimetry.," Med. Phys. 35, 206-216 (2008).
-
(2008)
Small Fields: Nonequilibrium Radiation Dosimetry
, vol.35
, pp. 206-216
-
-
Das, I.J.1
Ding, G.X.2
Ahnesjö, A.3
-
11
-
-
0037152478
-
-
Phys. Med. Biol..
-
G. Bednarz, M. S. Huq, and U. F. Rosenow, " Deconvolution of detector size effect for output factor measurement for narrow Gamma Knife radiosurgery beams.," Phys. Med. Biol. 47, 3643-3649 (2002).
-
(2002)
Deconvolution of Detector Size Effect for Output Factor Measurement for Narrow Gamma Knife Radiosurgery Beams
, vol.47
, pp. 3643-3649
-
-
Bednarz, G.1
Huq, M.S.2
Rosenow, U.F.3
-
12
-
-
0036732644
-
-
Med. Phys..
-
A. Mack, S. G. Scheib, J. Major, S. Gianolini, G. Pazmandi, H. Feist, H. Czempiel, and H. Kreiner, " Precision dosimetry for narrow photon beams used in radiosurgery-determination of Gamma Knife® output factors.," Med. Phys. 29, 2080-2089 (2002).
-
(2002)
Precision Dosimetry for Narrow Photon Beams Used in Radiosurgery- determination of Gamma Knife® Output Factors
, vol.29
, pp. 2080-2089
-
-
MacK, A.1
Scheib, S.G.2
Major, J.3
Gianolini, S.4
Pazmandi, G.5
Feist, H.6
Czempiel, H.7
Kreiner, H.8
-
13
-
-
0038247942
-
-
Med. Phys..
-
J. Tsai, M. J. Rivard, M. J. Engler, J. E. Mignano, D. E. Wazer, and W. A. Shucart, " Determination of the 4 mm Gamma Knife helmet relative output factor using a variety of detectors.," Med. Phys. 30, 986-992 (2003).
-
(2003)
Determination of the 4 Mm Gamma Knife Helmet Relative Output Factor Using a Variety of Detectors
, vol.30
, pp. 986-992
-
-
Tsai, J.1
Rivard, M.J.2
Engler, M.J.3
Mignano, J.E.4
Wazer, D.E.5
Shucart, W.A.6
-
15
-
-
0024380292
-
-
Radiat. Res..
-
B. E. Bjängard, J.-S. Tsai, and R. K. Rice, " Attenuation in very narrow photon beams.," Radiat. Res. 118, 195-200 (1989).
-
(1989)
Attenuation in Very Narrow Photon Beams
, vol.118
, pp. 195-200
-
-
Bjängard, B.E.1
Tsai, J.-S.2
Rice, R.K.3
-
19
-
-
0003474751
-
-
(W. H. Press, Cambridge University Press, Cambridge).
-
S. A. Teukolsky, W. T. Vetterling, and B. P. Flannery, Numerical Recipes in Fortran 77, The Art of Scientific Computing (W. H. Press, Cambridge University Press, Cambridge, 1992).
-
(1992)
Numerical Recipes in Fortran 77, the Art of Scientific Computing
-
-
Teukolsky, S.A.1
Vetterling, W.T.2
Flannery, B.P.3
-
20
-
-
0003492598
-
-
NRC of Canada, Report PIRS-702 (rev B), Ottawa, Ontario, Canada.
-
D. W. O. Rogers, I. Kawrakow, J. P. Seuntjens, B. R. B. Walters, and E. Mainegra-Hing, " NRC user codes for EGSnrc.," NRC of Canada, Report PIRS-702 (rev B), Ottawa, Ontario, Canada, 2003.
-
(2003)
NRC User Codes for EGSnrc
-
-
Rogers, D.W.O.1
Kawrakow, I.2
Seuntjens, J.P.3
Walters, B.R.B.4
Mainegra-Hing, E.5
-
21
-
-
0020046060
-
-
Med. Phys..
-
B. E. Bjängard and R. L. Siddon, " A note on equivalent circles, squares, and rectangles.," Med. Phys. 9, 258-260 (1982).
-
(1982)
A Note on Equivalent Circles, Squares, and Rectangles
, vol.9
, pp. 258-260
-
-
Bjängard, B.E.1
Siddon, R.L.2
|