메뉴 건너뛰기




Volumn 2, Issue , 2008, Pages 901-904

Mechanical defect detection of SF6 high voltage circuit breaker using wavelet based vibration signal analysis

Author keywords

[No Author keywords available]

Indexed keywords

CAPACITANCE; CIRCUIT BREAKING ARCS; DC GENERATORS; ELECTRIC CIRCUIT BREAKERS; INFORMATION TECHNOLOGY; INSPECTION; MAINTENANCE; SIGNAL ANALYSIS; SIGNAL PROCESSING; TELECOMMUNICATION SYSTEMS;

EID: 52949123640     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ECTICON.2008.4600576     Document Type: Conference Paper
Times cited : (13)

References (9)
  • 1
    • 52949114131 scopus 로고    scopus 로고
    • Facilities Instructions, Standards and Technique 3-16T 3-16, Maintenance of Power Circuit Breaker
    • Hydroelectric Research and Technical Service Group
    • Hydroelectric Research and Technical Service Group "Facilities Instructions, Standards and Technique 3-16T 3-16, Maintenance of Power Circuit Breaker", , US Department of the interior Bureau of Reclamation, d Colorado, 1999
    • (1999) US Department of the interior Bureau of Reclamation, d Colorado
  • 2
    • 0024751718 scopus 로고
    • A diagnostic technique to detect abnormal conditions of contacts measuring vibrations in metal enclosures of gas insulated switchgear
    • October
    • Y. Ohshita, A. Hashimoto, Y. Kurosawa, "A diagnostic technique to detect abnormal conditions of contacts measuring vibrations in metal enclosures of gas insulated switchgear", IEEE transaction on power delivery, vol. 4, pp. 2090-2094, October 1989.
    • (1989) IEEE transaction on power delivery , vol.4 , pp. 2090-2094
    • Ohshita, Y.1    Hashimoto, A.2    Kurosawa, Y.3
  • 3
    • 85069392854 scopus 로고
    • The application of development and diagnostic techniques to circuit breaker reliability
    • 02, published
    • C. A. Fawdrey, "The application of development and diagnostic techniques to circuit breaker reliability", Cigre' Session Paper Ref. 13-02, published: 1978.
    • (1978) Cigre' Session Paper
    • Fawdrey, C.A.1
  • 5
    • 0030262878 scopus 로고    scopus 로고
    • Vibration analysis for diagnostic testing of circuit breakers
    • October
    • M. Runde, G. E. Ottesen, B. Skyberg, M. Ohlen, "Vibration analysis for diagnostic testing of circuit breakers", IEEE transaction on power delivery, vol 11, no.4, pp 1816-1823, October 1996.
    • (1996) IEEE transaction on power delivery , vol.11 , Issue.4 , pp. 1816-1823
    • Runde, M.1    Ottesen, G.E.2    Skyberg, B.3    Ohlen, M.4
  • 8
    • 52949105673 scopus 로고    scopus 로고
    • Vibration Signal Analysis for Condition Monitoring of High Voltage Circuit Breakers
    • Thailand, May
    • T. Suwanasri, N. Charbkaew, T. Bunyagul, "Vibration Signal Analysis for Condition Monitoring of High Voltage Circuit Breakers", ECTI2007, Chaingrai, Thailand, May 2007
    • (2007) Chaingrai , vol.ECTI2007
    • Suwanasri, T.1    Charbkaew, N.2    Bunyagul, T.3
  • 9
    • 52949152708 scopus 로고    scopus 로고
    • Investigation on No-load Mechanical Endurance and Electrical Degradation of a Circuit Breaker Model under Short Circuit Current Interruption
    • Doctoral Thesis, RWTH Aachen, Germany, Feb
    • T. Suwanasri, "Investigation on No-load Mechanical Endurance and Electrical Degradation of a Circuit Breaker Model under Short Circuit Current Interruption",Doctoral Thesis, RWTH Aachen , Germany, Feb 2006
    • (2006)
    • Suwanasri, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.