메뉴 건너뛰기




Volumn 10, Issue 10, 2008, Pages 1205-1211

Entrainment from the para-Hisian region for differentiating atrioventricular node reentrant tachycardia from orthodromic atrioventricular reentrant tachycardia

Author keywords

Accessory pathway; Atrioventricular node reentrant tachycardia; Entrainment; His bundle; Orthodromic atrioventricular reentrant tachycardia

Indexed keywords

ADULT; AGED; ARTICLE; CATHETER ABLATION; CLINICAL ARTICLE; CONTROLLED STUDY; DIFFERENTIAL DIAGNOSIS; ELECTROPHYSIOLOGY; FEMALE; HEART ATRIOVENTRICULAR NODE; HEART RIGHT VENTRICLE; HEART VENTRICLE TACHYCARDIA; HIS BUNDLE POTENTIAL; HUMAN; MALE; PRIORITY JOURNAL; QRS COMPLEX; SENSITIVITY AND SPECIFICITY; SINUS RHYTHM; SUPRAVENTRICULAR TACHYCARDIA;

EID: 52949088589     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eun249     Document Type: Article
Times cited : (17)

References (11)
  • 2
    • 0033890233 scopus 로고    scopus 로고
    • Diagnostic value of tachycardia features and pacing maneuvers during paroxysmal supraventricular tachycardia
    • Knight BP, Ebinger M, Oral H, Kim MH, Sticherling C, Pelosi F et al. Diagnostic value of tachycardia features and pacing maneuvers during paroxysmal supraventricular tachycardia. J Am Coll Cardiol 2000;36:574-82.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 574-582
    • Knight, B.P.1    Ebinger, M.2    Oral, H.3    Kim, M.H.4    Sticherling, C.5    Pelosi, F.6
  • 3
    • 0034800862 scopus 로고    scopus 로고
    • Differentiation of atypical atrioventricular node re-entrant tachycardia from orthodromic reciprocating tachycardia using a septal accessory pathway by the response to ventricular pacing
    • Michaud GF, Tada H, Chough S, Baker R, Wasmer K, Sticherling C et al. Differentiation of atypical atrioventricular node re-entrant tachycardia from orthodromic reciprocating tachycardia using a septal accessory pathway by the response to ventricular pacing. J Am Coll Cardiol 2001;38:1163-7.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 1163-1167
    • Michaud, G.F.1    Tada, H.2    Chough, S.3    Baker, R.4    Wasmer, K.5    Sticherling, C.6
  • 4
    • 33646896057 scopus 로고    scopus 로고
    • First postpacing interval after tachycardia entrainment with correction for atrioventricular node delay: A simple maneuver for differential diagnosis of atrioventricular nodal reentrant tachycardias versus orthodromic reciprocating tachycardias
    • González-Torrecilla E, Arenal A, Atienza F, Osca J, García-Fernández J, Puchol A et al. First postpacing interval after tachycardia entrainment with correction for atrioventricular node delay: a simple maneuver for differential diagnosis of atrioventricular nodal reentrant tachycardias versus orthodromic reciprocating tachycardias. Heart Rhythm 2006;3:674-9.
    • (2006) Heart Rhythm , vol.3 , pp. 674-679
    • González-Torrecilla, E.1    Arenal, A.2    Atienza, F.3    Osca, J.4    García-Fernández, J.5    Puchol, A.6
  • 5
    • 0024402602 scopus 로고
    • Diagnostic value of comparison of ventriculoatrial interval during junctional tachycardia and right ventricular apical pacing
    • Crozier I, Wafa S, Ward D, Camm J. Diagnostic value of comparison of ventriculoatrial interval during junctional tachycardia and right ventricular apical pacing. Pacing Clin Electrophysiol 1989;12:942-53.
    • (1989) Pacing Clin Electrophysiol , vol.12 , pp. 942-953
    • Crozier, I.1    Wafa, S.2    Ward, D.3    Camm, J.4
  • 6
    • 0027372274 scopus 로고
    • Ventricular fusion during resetting and entrainment of orthodromic supraventricular tachycardia involving septal accessory pathways. Implications for the differential diagnosis with atrioventricular nodal reentry
    • Ormaetxe JM, Almendral J, Arenal A, Martínez-Alday JD, Pastor A, Villacastin JP et al. Ventricular fusion during resetting and entrainment of orthodromic supraventricular tachycardia involving septal accessory pathways. Implications for the differential diagnosis with atrioventricular nodal reentry. Circulation 1993;88:2623-31.
    • (1993) Circulation , vol.88 , pp. 2623-2631
    • Ormaetxe, J.M.1    Almendral, J.2    Arenal, A.3    Martínez-Alday, J.D.4    Pastor, A.5    Villacastin, J.P.6
  • 8
    • 0347992793 scopus 로고    scopus 로고
    • Para-Hisian entrainment: A novel pacing maneuver to differentiate orthodromic atrioventricular reentrant tachycardia from atrioventricular nodal reentrant tachycardia
    • Reddy VY, Jongnarangsin K, Albert CM, Sabbour H, Keane D, Mela T et al. Para-Hisian entrainment: a novel pacing maneuver to differentiate orthodromic atrioventricular reentrant tachycardia from atrioventricular nodal reentrant tachycardia. J Cardiovasc Electrophysiol 2003;14:1321-8.
    • (2003) J Cardiovasc Electrophysiol , vol.14 , pp. 1321-1328
    • Reddy, V.Y.1    Jongnarangsin, K.2    Albert, C.M.3    Sabbour, H.4    Keane, D.5    Mela, T.6
  • 9
    • 33845220024 scopus 로고    scopus 로고
    • Clinical implications of 'pure' hisian pacing in addition to para-Hisian pacing for the diagnosis of supraventricular tachycardia
    • Takatsuki S, Mitamura H, Tanimoto K, Fukuda Y, Ieda M, Miyoshi S et al. Clinical implications of 'pure' hisian pacing in addition to para-Hisian pacing for the diagnosis of supraventricular tachycardia. Heart Rhythm 2006;3:1412-8.
    • (2006) Heart Rhythm , vol.3 , pp. 1412-1418
    • Takatsuki, S.1    Mitamura, H.2    Tanimoto, K.3    Fukuda, Y.4    Ieda, M.5    Miyoshi, S.6
  • 10
    • 9544220772 scopus 로고    scopus 로고
    • Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node
    • Hirao K, Otomo K, Wang X, Beckman KJ, McClelland JH, Widman L et al. Para-Hisian pacing. A new method for differentiating retrograde conduction over an accessory AV pathway from conduction over the AV node. Circulation 1996;94:1027-35.
    • (1996) Circulation , vol.94 , pp. 1027-1035
    • Hirao, K.1    Otomo, K.2    Wang, X.3    Beckman, K.J.4    McClelland, J.H.5    Widman, L.6
  • 11
    • 0030798736 scopus 로고    scopus 로고
    • Use of only a regular diagnostic His-bundle catheter for both fast and reproducible 'para-Hisian pacing' and stable right ventricular pacing
    • Heidbüchel H, Ector H, Adams J, Van de Werf F. Use of only a regular diagnostic His-bundle catheter for both fast and reproducible 'para-Hisian pacing' and stable right ventricular pacing. J Cardiovasc Electrophysiol 1997;8:1121-32.
    • (1997) J Cardiovasc Electrophysiol , vol.8 , pp. 1121-1132
    • Heidbüchel, H.1    Ector, H.2    Adams, J.3    Van de Werf, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.