메뉴 건너뛰기




Volumn 24, Issue 5, 2008, Pages 383-389

Computer-aided volume measurement of posttraumatic orbits reconstructed with AO titanium mesh plates: Accuracy and reliability

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; FEMALE; FOLLOW UP; HUMAN; IMAGE RECONSTRUCTION; IMAGING SYSTEM; MALE; ORBIT; ORBIT FRACTURE; ORBIT INJURY; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; RELIABILITY; BONE PLATE; EYE SURGERY; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; OSTEOSYNTHESIS; PLASTIC SURGERY; PROSPECTIVE STUDY; RADIOGRAPHY; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING;

EID: 52649181146     PISSN: 07409303     EISSN: None     Source Type: Journal    
DOI: 10.1097/IOP.0b013e318185a72c     Document Type: Article
Times cited : (56)

References (26)
  • 1
    • 0025900854 scopus 로고
    • Reconstruction of internal orbital fractures with Vitallium mesh
    • Sargent LA, Fulks KD. Reconstruction of internal orbital fractures with Vitallium mesh. Plast Reconstr Surg 1991;88:31-8.
    • (1991) Plast Reconstr Surg , vol.88 , pp. 31-38
    • Sargent, L.A.1    Fulks, K.D.2
  • 3
    • 0036144948 scopus 로고    scopus 로고
    • Safety of titanium mesh for orbital reconstruction
    • discussion 7-9
    • Gear AJ, Lokeh A, Aldridge JH, et al. Safety of titanium mesh for orbital reconstruction. Ann Plast Surg 2002;48:1-7; discussion 7-9.
    • (2002) Ann Plast Surg , vol.48 , pp. 1-7
    • Gear, A.J.1    Lokeh, A.2    Aldridge, J.H.3
  • 4
    • 0036839099 scopus 로고    scopus 로고
    • Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity
    • Gellrich NC, Schramm A, Hammer B, et al. Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity. Plast Reconstr Surg 2002;110:1417-29.
    • (2002) Plast Reconstr Surg , vol.110 , pp. 1417-1429
    • Gellrich, N.C.1    Schramm, A.2    Hammer, B.3
  • 5
    • 0037381327 scopus 로고    scopus 로고
    • Assessment of internal orbital reconstructions for pure blowout fractures: Cranial bone grafts versus titanium mesh
    • Ellis E III, Tan Y. Assessment of internal orbital reconstructions for pure blowout fractures: cranial bone grafts versus titanium mesh. J Oral Maxillofac Surg 2003;61:442-53.
    • (2003) J Oral Maxillofac Surg , vol.61 , pp. 442-453
    • Ellis III, E.1    Tan, Y.2
  • 6
    • 4444340230 scopus 로고    scopus 로고
    • Navigation-aided reconstruction of medial orbital wall and floor contour in craniomaxillofacial reconstruction
    • Schmelzeisen R, Gellrich NC, Schoen R, et al. Navigation-aided reconstruction of medial orbital wall and floor contour in craniomaxillofacial reconstruction. Injury 2004;35:955-62.
    • (2004) Injury , vol.35 , pp. 955-962
    • Schmelzeisen, R.1    Gellrich, N.C.2    Schoen, R.3
  • 8
    • 33748976513 scopus 로고    scopus 로고
    • Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures
    • Metzger MC, Schon R, Weyer N, et al. Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures. Ophthalmology 2006;113:1863-8.
    • (2006) Ophthalmology , vol.113 , pp. 1863-1868
    • Metzger, M.C.1    Schon, R.2    Weyer, N.3
  • 9
    • 33847183545 scopus 로고    scopus 로고
    • Semiautomatic procedure for individual preforming of titanium meshes for orbital fractures
    • Metzger MC, Schon R, Zizelmann C, et al. Semiautomatic procedure for individual preforming of titanium meshes for orbital fractures. Plast Reconstr Surg 2007;119:969-76.
    • (2007) Plast Reconstr Surg , vol.119 , pp. 969-976
    • Metzger, M.C.1    Schon, R.2    Zizelmann, C.3
  • 10
    • 0021956772 scopus 로고
    • Orbital volume measurements in enophthalmos using three-dimensional CT imaging
    • Bite U, Jackson IT, Forbes GS, Gehring DG. Orbital volume measurements in enophthalmos using three-dimensional CT imaging. Plast Reconstr Surg 1985;75:502-8.
    • (1985) Plast Reconstr Surg , vol.75 , pp. 502-508
    • Bite, U.1    Jackson, I.T.2    Forbes, G.S.3    Gehring, D.G.4
  • 11
    • 0021838008 scopus 로고
    • Volume measurements of normal orbital structures by computed tomographic analysis
    • Forbes G, Gehring DG, Gorman CA, et al. Volume measurements of normal orbital structures by computed tomographic analysis. AJR Am J Roentgenol 1985;145:149-54.
    • (1985) AJR Am J Roentgenol , vol.145 , pp. 149-154
    • Forbes, G.1    Gehring, D.G.2    Gorman, C.A.3
  • 13
    • 0027406012 scopus 로고
    • Orbital volume measurement in the management of pure blowout fractures of the orbital floor
    • Charteris DG, Chan CH, Whitehouse RW, Noble JL. Orbital volume measurement in the management of pure blowout fractures of the orbital floor. Br J Ophthalmol 1993;77:100-2.
    • (1993) Br J Ophthalmol , vol.77 , pp. 100-102
    • Charteris, D.G.1    Chan, C.H.2    Whitehouse, R.W.3    Noble, J.L.4
  • 14
    • 0028146974 scopus 로고
    • Prediction of enophthalmos by computed tomography after "blow out" orbital fracture
    • Whitehouse RW, Batterbury M, Jackson A, Noble JL. Prediction of enophthalmos by computed tomography after "blow out" orbital fracture. Br J Ophthalmol 1994;78:618-20.
    • (1994) Br J Ophthalmol , vol.78 , pp. 618-620
    • Whitehouse, R.W.1    Batterbury, M.2    Jackson, A.3    Noble, J.L.4
  • 15
    • 0031911577 scopus 로고    scopus 로고
    • Prediction of late enophthalmos by volumetric analysis of orbital fractures
    • Raskin EM, Millman AL, Lubkin V, et al. Prediction of late enophthalmos by volumetric analysis of orbital fractures. Ophthal Plast Reconstr Surg 1998;14:19-26.
    • (1998) Ophthal Plast Reconstr Surg , vol.14 , pp. 19-26
    • Raskin, E.M.1    Millman, A.L.2    Lubkin, V.3
  • 16
    • 0034278121 scopus 로고    scopus 로고
    • Dimensions and volumes of the orbit and orbital fat in posttraumatic enophthalmos
    • Ramieri G, Spada MC, Bianchi SD, Berrone S. Dimensions and volumes of the orbit and orbital fat in posttraumatic enophthalmos. Dentomaxillofac Radiol 2000;29:302-11.
    • (2000) Dentomaxillofac Radiol , vol.29 , pp. 302-311
    • Ramieri, G.1    Spada, M.C.2    Bianchi, S.D.3    Berrone, S.4
  • 17
    • 0028335064 scopus 로고
    • Method for preparing an exact-size model using helical volume scan computed tomography
    • Ono I, Gunji H, Suda K, Kaneko F. Method for preparing an exact-size model using helical volume scan computed tomography. Plast Reconstr Surg 1994;93:1363-71.
    • (1994) Plast Reconstr Surg , vol.93 , pp. 1363-1371
    • Ono, I.1    Gunji, H.2    Suda, K.3    Kaneko, F.4
  • 18
    • 0035016865 scopus 로고    scopus 로고
    • Long-term results following reconstruction of craniofacial defects with titanium micro-mesh systems
    • Kuttenberger JJ, Hardt N. Long-term results following reconstruction of craniofacial defects with titanium micro-mesh systems. J Craniomaxillofac Surg 2001;29:75-81.
    • (2001) J Craniomaxillofac Surg , vol.29 , pp. 75-81
    • Kuttenberger, J.J.1    Hardt, N.2
  • 19
    • 0035745727 scopus 로고    scopus 로고
    • Various applications of titanium mesh screen implant to orbital wall fractures
    • Park HS, Kim YK, Yoon CH. Various applications of titanium mesh screen implant to orbital wall fractures. J Craniofac Surg 2001;12:555-60.
    • (2001) J Craniofac Surg , vol.12 , pp. 555-560
    • Park, H.S.1    Kim, Y.K.2    Yoon, C.H.3
  • 20
    • 0036843046 scopus 로고    scopus 로고
    • Evaluation of computer-based area and volume measurement from coronal computed tomography scans in isolated blowout fractures of the orbital floor
    • discussion 1273-4
    • Ploder O, Klug C, Voracek M, et al. Evaluation of computer-based area and volume measurement from coronal computed tomography scans in isolated blowout fractures of the orbital floor. J Oral Maxillofac Surg 2002;60:1267-72; discussion 1273-4.
    • (2002) J Oral Maxillofac Surg , vol.60 , pp. 1267-1272
    • Ploder, O.1    Klug, C.2    Voracek, M.3
  • 21
    • 0038513908 scopus 로고    scopus 로고
    • Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures
    • Fan X, Li J, Zhu J, Li H, et al. Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures. Ophthal Plast Reconstr Surg 2003;19:207-11.
    • (2003) Ophthal Plast Reconstr Surg , vol.19 , pp. 207-211
    • Fan, X.1    Li, J.2    Zhu, J.3    Li, H.4
  • 22
    • 34548694353 scopus 로고    scopus 로고
    • Secondary post-traumatic enophthalmos: High-resolution magnetic resonance imaging compared with multislice computed tomography in postoperative orbital volume measurement
    • Kolk A, Pautke C, Schott V, et al. Secondary post-traumatic enophthalmos: high-resolution magnetic resonance imaging compared with multislice computed tomography in postoperative orbital volume measurement. J Oral Maxillofac Surg 2007;65:1926-34.
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 1926-1934
    • Kolk, A.1    Pautke, C.2    Schott, V.3
  • 23
    • 15044352366 scopus 로고    scopus 로고
    • OsiriX: An open-source software for navigating in multidimensional DICOM images
    • Rosset A, Spadola L, Ratib O. OsiriX: an open-source software for navigating in multidimensional DICOM images. J Digit Imaging 2004;17:205-16.
    • (2004) J Digit Imaging , vol.17 , pp. 205-216
    • Rosset, A.1    Spadola, L.2    Ratib, O.3
  • 24
    • 0036189754 scopus 로고    scopus 로고
    • Cranial reconstruction with computer-generated hard-tissue replacement patient-matched implants: Indications, surgical technique, and long-term follow-up
    • Eppley BL, Kilgo M, Colemann JJ. Cranial reconstruction with computer-generated hard-tissue replacement patient-matched implants: indications, surgical technique, and long-term follow-up. Plast Reconstr Surg 2002;109:864-71.
    • (2002) Plast Reconstr Surg , vol.109 , pp. 864-871
    • Eppley, B.L.1    Kilgo, M.2    Colemann, J.J.3
  • 25
    • 27744526166 scopus 로고    scopus 로고
    • New frontiers in calvarial reconstruction: Integrating computer-assisted design and tissue engineering in cranioplasty
    • Chim H, Schantz JT. New frontiers in calvarial reconstruction: integrating computer-assisted design and tissue engineering in cranioplasty. Plast Reconstr Surg 2005;116:1726-41.
    • (2005) Plast Reconstr Surg , vol.116 , pp. 1726-1741
    • Chim, H.1    Schantz, J.T.2
  • 26
    • 33846587469 scopus 로고    scopus 로고
    • Complex orbito-fronto-temporal reconstruction using computer-designed PEEK implant
    • Scolozzi P, Martinez A, Jaques B. Complex orbito-fronto-temporal reconstruction using computer-designed PEEK implant. J Craniofac Surg 2007;18:224-8.
    • (2007) J Craniofac Surg , vol.18 , pp. 224-228
    • Scolozzi, P.1    Martinez, A.2    Jaques, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.