Volumn , Issue , 2008, Pages

Influence of the geometrical parameters of power transformer insulation on the frequency domain spectroscopy measurement

Author keywords

Barrier; Duct geometry; Frequency domain spectroscopy; Power transformer; Spacer

Indexed keywords

DISTRIBUTED POWER GENERATION; ELECTRIC CURRENTS; ELECTRIC INSTRUMENT TRANSFORMERS; ELECTRIC TRANSFORMER TESTING; ELECTRIC TRANSFORMERS; ENERGY CONVERSION; FREQUENCY DOMAIN ANALYSIS; HEALTH; INSULATING OIL; MOISTURE; NUMERICAL ANALYSIS; OIL FILLED TRANSFORMERS; PAPER; POTENTIAL ENERGY; POTENTIAL ENERGY SURFACES; POWER TRANSFORMERS; TRANSFORMER SUBSTATIONS;

EID: 52649177098     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PES.2008.4596601     Document Type: Conference Paper
Times cited : (22)

References (15)
  • 1
    • 35348892705 scopus 로고    scopus 로고
    • Impact of Temperature on the Frequency Domain Dielectric Spectroscopy for the Diagnosis of Power Transformer Insulation
    • Montreal
    • J. H. Yew, T. K. Saha, and A. Thomas, "Impact of Temperature on the Frequency Domain Dielectric Spectroscopy for the Diagnosis of Power Transformer Insulation,"Proceedings of the IEEE Power Engineering Society General Meeting, Montreal, 2006.
    • (2006) Proceedings of the IEEE Power Engineering Society General Meeting
    • Yew, J.H.1    Saha, T.K.2    Thomas, A.3
  • 2
    • 52349096934 scopus 로고    scopus 로고
    • Effects of Moisture and Temperature on the Frequency Domain Spectroscopy Analysis of Power Transformer Insulation
    • Pittsburgh, Pennsylvania, USA
    • J. H. Yew, M. K. Pradhan, and S. T. K., "Effects of Moisture and Temperature on the Frequency Domain Spectroscopy Analysis of Power Transformer Insulation," Proceedings of the IEEE Power Engineering Society General Meeting, Pittsburgh, Pennsylvania, USA, 2008.
    • (2008) Proceedings of the IEEE Power Engineering Society General Meeting
    • Yew, J.H.1    Pradhan, M.K.2    Saha, T.K.3
  • 3
    • 33847704075 scopus 로고    scopus 로고
    • D. Linhjell, L. Lundgaard, and U. Gafvert, Dielectric response of mineral oil impregnated cellulose and the impact of aging, Dielectrics and Electrical Insulation, IEEE Transactions on [see also Electrical Insulation, IEEE Transactions on], 14, no. 1, pp. 156-169, 2007.
    • D. Linhjell, L. Lundgaard, and U. Gafvert, "Dielectric response of mineral oil impregnated cellulose and the impact of aging," Dielectrics and Electrical Insulation, IEEE Transactions on [see also Electrical Insulation, IEEE Transactions on], vol. 14, no. 1, pp. 156-169, 2007.
  • 4
    • 84872155325 scopus 로고    scopus 로고
    • Conformal Thermal Models for Optimal Loading and Elapsed Life Estimation of Power Transformer
    • Bangalore: Indian Institute of Science
    • M. K. Pradhan, "Conformal Thermal Models for Optimal Loading and Elapsed Life Estimation of Power Transformer," in High Voltage Engineering Department. Bangalore: Indian Institute of Science, 2005.
    • (2005) High Voltage Engineering Department
    • Pradhan, M.K.1
  • 5
    • 1242330865 scopus 로고    scopus 로고
    • Applications of dielectric spectroscopy in time and frequency domain for HV power equipment
    • W. S. Zaengl, "Applications of dielectric spectroscopy in time and frequency domain for HV power equipment," Electrical Insulation Magazine, IEEE, vol. 19, no. 6, pp. 9-22, 2003.
    • (2003) Electrical Insulation Magazine, IEEE , vol.19 , Issue.6 , pp. 9-22
    • Zaengl, W.S.1
  • 9
    • 52649136938 scopus 로고    scopus 로고
    • TEC 60814, Insulating liquids: oil-impregnated paper and pressboard: determination of water by automatic coulometric Karl Fischer titration., 2nd ed. Geneva, Switzerland, 1989.
    • TEC 60814, "Insulating liquids: oil-impregnated paper and pressboard: determination of water by automatic coulometric Karl Fischer titration.", 2nd ed. Geneva, Switzerland, 1989.
  • 11
    • 33745634614 scopus 로고    scopus 로고
    • Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation
    • C. Ekanayake, S. M. Gubanski, A. Graczkowski, and K. Walczak, "Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation," Power Delivery, IEEE Transactions on, vol. 21, no. 3, pp. 1309-1317, 2006.
    • (2006) Power Delivery, IEEE Transactions on , vol.21 , Issue.3 , pp. 1309-1317
    • Ekanayake, C.1    Gubanski, S.M.2    Graczkowski, A.3    Walczak, K.4
  • 12
    • 52649110506 scopus 로고    scopus 로고
    • Determination of water content in transformer solid insulation frequency domain spectroscopy
    • B. Garcia, B. Valecillos, and J. C. Burgos, "Determination of water content in transformer solid insulation frequency domain spectroscopy," WSEAS Transactions on Power Systems, vol. 1, no. 2, pp. 570-5, 2006.
    • (2006) WSEAS Transactions on Power Systems , vol.1 , Issue.2 , pp. 570-575
    • Garcia, B.1    Valecillos, B.2    Burgos, J.C.3
  • 15
    • 42549159298 scopus 로고    scopus 로고
    • Application of Dielectric Spectroscopy for Estimating Moisture Content in Power Transformer
    • Goteborg: Chalmers University of Technology
    • C. Ekanayake, "Application of Dielectric Spectroscopy for Estimating Moisture Content in Power Transformer," in Department of Electric Power Engineering. Goteborg: Chalmers University of Technology, 2003, pp. 119.
    • (2003) Department of Electric Power Engineering , pp. 119
    • Ekanayake, C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.